Abstract
A study was carried out on suspended dust, bacterial and fungal aerosols in a four-storey flourmill building located in Giza, Egypt. Airborne microorganisms were quantitatively isolated using liquid impinger and gravimetric samplers during the period from March 2004 to February 2005. Suspended dust varied from 1.96 to 16.3 mg m−3 and 0.69 to 1.8 mg m−3 in the indoor and outdoor environments, respectively. Suspended dust was significantly greater (P < 0.05) at bran package, double roller, purifiers and flour storage units in comparison to the outdoor reference site. The dust levels exceed the occupational exposure limit (OEL) of 0.5 mg m−3 for flour dust. Airborne microbial counts were found at median values, between sampling locations, ranged from 0 to >104 CFU m−3. Gram-negative bacteria were found in small numbers (0–102 CFU m−3). The highest concentration of actinomycetes (>103 CFU m−3) was detected in the storage unit. Airborne fungal counts were found at the median values, between sampling locations, varied from 103 to 104 CFU m−3. The counts of airborne bacteria and fungi were significantly greater (P < 0.05) at the purifiers and double roller mill units in comparison to the outdoor reference site using the liquid impinger sampler. Microbial levels associated with bulk deposited dust averaged between 105 and 106 CFU g−1. Alcaligenes (5.4%) Pseudomonas (3.87%) and Enterobacter (3.1%) were the predominant Gram-negative species while Bacillus (29.4%) and Micrococci (13.9%) were the major components of Gram-positive bacteria. Aspergillus and Penicillium were the predominant fungal types indoor whereas Cladosporium (35.2%) and Aspergillus species (22.2%) were the predominant fungal types outdoor. A number of allergenic and toxigenic bioaerosols were found in the flourmill workplace.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
1 Introduction
In recent years the awareness of bioaerosols within indoor environments has grown. Bioaerosols have been studied in different occupational and nonoccupational settings: markets (Narayn, Ravichandran, & Sullia, 1982), poultry farms (Surekha, Krishnareddi, & Reddi, 1996), animal feed industry (Abdel Hameed, Shakour, & Yasser, 2003), rice mill (Desai & Ghosh 2003), saw mill (Jothish & Nayar, 2004), schools (Aydogdu, Asan, Otkum, & Ture, 2005), bakeries and flourmills (Musk et al., 1989; Singh & Singh, 1994).
Grain dust harbors both viable and nonviable microorganisms and their toxins (Szponar & Larsson, 2001). In a study of a British bakery up to 1.2 × 103 CFU m−3 of air composition mostly Penicillium species were found where flour was weighed (Crook, Venables, Lacey, Musk, & Newman Taylor, 1988). Swan and Crook (1998) found that airborne fungal spores reached 6.7 × 104 CFU m3 in wheat for humans and 1.6 × 106 CFU m−3 in animal feed wheat; bacteria reached 1.6 × 105 CFU m−3 and 2.3 × 106 CFU m−3, respectively, whereas thermophilic bacteria and actinomycetes reached 8 × 102 CFU m−3 and 3.9 × 103 CFU m−3, respectively. High concentrations of microorganisms have been found in airborne and settled dust samples in European and North American grain industries (DeLucca, Godshall, & Palmgren, 1984; Eduard 1997). Moreover, Karpinski (2003) reported that employees in a Canadian flourmill were exposed to dust level ranging from 0.5 to 20 mg m−3.
Inhalation of grain dusts can decrease lung function and induce the development of immunological respiratory symptoms, which may include allergic and immunotoxic effects (Rylander, 1994). The etiology of toxic pneumonitis is unknown but it has also been speculated that one causative factor could be the inhalation of fungi, bacteria, actinomycetes and endotoxins that are present in flour and saw mills (Chan-Yeung, Enarson, & Kennedy, 1992; Malmberg, Rask-Andersen, Lundholm, & Palmgren, 1990). Allergenic and toxic effects may be the health hazardous associated with exposure to Gram-negative bacteria (Olenchock, 1990), actinomycetes (Lacey & Crook, 1988) and fungi (Sumi, Takeuchi, Miyakawa, & Nagura, 1994). Many of the microorganisms found in grain dust are well-known respiratory sensitizers, e.g., Cladosporium, Alternaria, Aspergillus, Penicillium (Dutkiewicz, Kus, Dutkiewicz, & Warren, 1985; Dutkiewicz et al., 1989) while Enterobacter agglomerans may be a source of endotoxins (Dutkiewicz, 1978). Moreover, workers exposed to the dust in flourmills have developed chronic bronchial irritation and asthma (Meo, 2004; Taytard et al., 1988).
The state of knowledge about biologically originated indoor air pollution in Egypt has been narrow and inadequate. A qualitative and quantitative knowledge of airborne bacteria, fungi and actinomycetes in Egyptian flourmills is essential for the effective diagnosis of associated health problems. The present study aims to evaluate the concentrations of suspended dust, bacteria, fungi and actinomycetes at different locations within a flourmill in Giza, Egypt.
2 Materials and methods
2.1 Description of flour mill
A four-storey flourmill building located in Giza, Egypt was chosen for this study. The wheat grain passes through the plan sifters at two stages in the milling process (break and reduction systems). The stock flour is sifted into various fractions (semolina, middling and bran) for further processed after each break roller mill. A series of rollers interspersed with plan sifters are used to roll and reduce semolina into fine flour. Semolina stock and finer endosperm particles are separated in the purifiers and sent to the reduction rollers. The purifiers use a combination of sieve sizes to remove the remaining fine bran particles. Finally, flour is packed into 50-kg bags and stored.
2.2 Air sampling locations
Air samples were collected at the following sites: (1) the bran package unit, (2) the double roller mill and wheat scourers, (3) the flour packing machine and storage unit, (4) the purifiers, horizontal bran finishers, flour collecting and screw conveyors, and (5) an outdoor reference site. The air samples were taken between 11 AM and 3 PM during the normal working hours. Eight sampling trials were taken from March 2004 to February 2005. The air samples were taken from fixed sites at the center of the each unit, whereas the outdoor samples were collected 40 m from the flourmill, near a management office building. Indoor and outdoor air samples were collected at a height of 1.5 m, the breathing zone, above ground level.
2.3 Biological air sampling
Air samples were collected by liquid impinger (AGI-30) sampler, containing 25 ml phosphate buffer solution (KH2PO4 0.4%, K2HPO4 1.36%). The air samples were collected at a flow rate of 12.5 l min−1 for 15 min. Aliquots (0.2 ml) of the original sample and its serial dilutions (up to 104) were spread-plated in duplicate onto the surface of malt extract agar (MEA), trypticase soy agar (TSA), MacConkey agar (Mac) and starch casein agar (SC), (Difco, Detroit, Mi) for counting of fungi, total viable bacteria, Gram-negative bacteria and actinomycetes, respectively. Moreover, two plates for each microbial indicator, containing the previously mentioned media, were exposed to the air for 10 min using gravitational methodology (Pelczar, Chan, & Krieg, 1993).
2.4 Suspended dust and its microbial contents (Aerosol monitor)
Suspended dust was collected on sterilized preweighed cellulose nitrate membrane filters (0.45 μm, pore size and 25 mm, diameter). One-hour samples were obtained using an open face holder (25 mm, diameter, Casella, London) and sampling pump calibrated to draw 8 l min−1. Suspended dust concentrations were determined gravimetrically and expressed in mg m−3. The filters were washed with 10 ml phosphate buffer solution with 0.1 ml Tween 80. Aliquots (0.1 ml) of the original suspension and its dilutions (up to 105) were spread-plated onto the surface of the previously mentioned media.
2.5 Deposited dust
Bulk deposited dust samples were only collected indoors, using a sterilized spatula and plastic bag, from the centre of the different flourmill locations and were immediately sealed. Ten grams of the dust was mixed with 100 ml phosphate buffer, shaken vigorously for ∼1 h and serially diluted tenfold to 106. Aliquots (0.1 ml) of the final two dilutions were spread-plated in duplicate onto the previously mentioned media.
2.6 The microbial analysis
The bacterial plates were incubated at 25°C (trypticase soy agar) and 37°C (MacConkey agar) for 48 h for the environmental bacteria and Gram-negative bacteria, respectively. Fungal and actinomycete plates were incubated at 28°C for 5 and 7–14 days, respectively. The resultant colonies were reported as colony-forming unit (CFU m−3) for air and aerosol monitor and deposited dust were reported as colony forming unit per gram (CFU g−1).
Representative bacterial colonies of the most prevalent from each site were selected and isolated into pure culture. They were identified using colony morphology, Gram staining and biochemical reactions (Vanderzent & Nickelson, 1969). Actinomycetes could not be identified at the species level and only numerical results are presented. Macroscopic and microscopic investigation of actinomycetes was carried out according to Waksman (1967). Fungal isolates were mainly identified by the direct observation on the basis of micro-and macro-morphological features using various literatures (Barnett & Hunter, 1999; St-Germain & Summerbell, 1996). Aerodynamic diameter (dae) of fungal spores was calculated from the physical diameter assuming a density of 1 g cm−3 and sphere shape.
Student’s t-test (P < 0.05) was used to estimate the significant difference between the mean concentrations of suspended dust and airborne microorganisms using different samplers at all sampling locations (Gregory, 1963).
3 Results
Suspended dust ranged from 1.96 to 16.3 mg m−3 in the work environment with median values between sampling locations ranging from 2.7 to 6.46 mg m−3, with the highest degree of dust pollution (16.3 mg m−3) found in the flour storage unit. Suspended dust concentrations were significantly greater (P < 0.05) at the bran package; double roller, and storage units in comparison to the outdoor reference samples (Table 1).
Tables 1 and 2 summarize the concentrations of the microbial indicators using gravimetric and liquid impinger samplers. The median microbial counts between sampling locations ranged from 7.14 × 103 to 7.9 × 104 CFU m−3 for environment bacteria, 0 to 2.82 × 102 CFU m−3 for Gram-negative bacteria, 4.23 × 102 to 2.15 × 103 CFU m−3 for actinomycetes and 1.06 × 103 to 3.1 × 104 CFU m−3 for fungi using gravimetric and AGI samplers. Outdoor reference samples were 1–2-fold lower than those indoors. Gram-negative bacteria were only detected by using liquid impinger sampler (Table 2).
Significant differences (P < 0.05) were observed between the counts of total bacteria and fungi at the purifiers and double roller units in comparison to the outdoor reference samples using the liquid impinger sampler (Table 2). Actinomycetes constituted 0.6–4% and 2.6–40% of the total bacterial counts using the liquid impinger and gravimetric samplers, respectively. The highest concentration of actinomycetes was found in the flour packing unit using gravimetric sampler.
Deposited bulk dust contained higher levels of microbial indicators >105 CFU g−1. Total Bacteria, Gram-negative bacteria, actinomycetes and fungi were found at median values of 4.67 × 105, 9.5 × 104, 2 × 104 and 5 × 105 CFU g−1, respectively (Table 3).
Airborne Gram-positive and negative bacteria constituted 83.7 and 16.3% of the total bacterial isolates, respectively. Bacillus (29.4%) and Micrococcus spp. (13.9%) were the major components of the Gram-positive bacteria, whereas Alcaligenes (5.4%), Pseudomonas (3.87%) and Enterobacter spp. (3.1%) were the predominant Gram-negative bacteria (Table 4).
A total of 640 airborne fungal isolates belonging to 24 fungal genera were identified (Table 5). Aspergillus (26.78–78.3%), Penicillium (7.4–11.8%) and yeasts (4.96–27.7%) were the predominant species identified indoor areas, whereas Cladosporium (35.2%), and Aspergillus species (22.2%) were the predominant outdoor species. Among the Aspergillus species, A. candidus, A. niger and A. ochraceus were found at all sites while A. fumigatus and A. flavus were only detected indoors. The highest percentage of Aspergillus flavus was found in the storage unit. Zygomycete was found at low levels and represented by Rhizopus, Absidia and Mucor. Field fungi (Fusarium), prestorage (A. flavus and A. parasiticus), postharvest (A. ochraceus), stored xerophilic (Eurotium), less xerophilic (A. candidus) and high moisture content (Stachybotrys, Ulocladium and A. fumigatus) were detected in the flourmill units.
A total of six fungal genera were associated with suspended dust. Aspergillus, Cladosporium and Penicillium were frequently recovered at all flourmill locations (Table 6). Among Aspergillus species, only A. parasiticus was found in all sampling locations.
Table 5 shows the aerodynamic diameter (dae) of fungal spores. Neither fungal diameter nor shape are constant, however most fungal spores have different shapes ranging from globose to fiber-like. Alternaria, Bipolaris, Rhizopus, Ulocladium and Epicoccum have dae > 5 μm, whereas Aspergillus, Penicillium, Spicaria and Fusarium (short axis) have dae < 5 μm.
4 Discussion
The suspended dust levels exceeded the OEL of 0.5 mg m−3 for flour dust as suggested by the American Conference of Governmental Industrial Hygienists (ACGIH, Karpinski, 2003). This is attributed to the milling activities, lack of control measures, insufficient ventilation and floor cleaning. The results of the present study correspond with Nieuwenhuijsen et al. (1994) who found suspended dust in the range of 0.5–16.9 mg m−3 in a flourmill in England. Desai and Ghosh (2003) found suspended dust concentrations significantly greater (P < 0.01) at the workplace site compared to the control site.
The high microbial content associated with deposited dust indicates that microorganisms may be associated with grains both during harvesting and after storage. Therefore, resuspension of settled dust into the air may be a plausible explanation for increasing airborne microbial contents in dusty units. Microorganism associated dust may be inhaled by workers. The results of the present study correspond with Dutkiewicz (1986) and Dutkiewicz et al.(1989) who found high microbial concentrations in airborne and settled dust during grain handling.
Different sampling methods were used to maximize recovery of the various microorganisms present in the flourmill environment. The AGI and gravimetric samplers were chosen for air sampling because they can be used in highly contaminated areas without overloading (Swan & Crook, 1998). Additionally, the cut diameter (d 50) of AGI is 0.3 μm (Cown, Kethley, & Fincher, 1957), therefore it is useful for studying the respiratory infection potential of bioaerosols (Jensen, Lighthart, Mohr, & Shaffer, 1994). In the present study the AGI sampler gave significant higher airborne microbial counts at indoor locations in comparison to the outdoor location. Because flour milling processes generate high concentrations of bioaerosols in the workplace environment (indoor). In addition, AGI provides protection for vegetative organisms and improves recovery of viable, culturable, organisms (Macher, Chatigny, & Burge, 1995). In contrast the gravimetric sampler yielded higher numbers of recovered actinmoycetes. Quantitatively, concentrations of fungi, actinomycetes and bacteria differed little in suspended dust from different locations within the flourmill. The absence of significant variations in the microbial aerosols (associated with suspended dust) may be due to the same composition and nature of dust particles at all locations, and may confirm that AGI provides some protection during the sampling process for air microorganisms.
In the present study, Gram-negative bacteria were found in low numbers, and were not recorded through the gravimetric method. These results could be attributed to their sensitivity to environmental stresses, and confirmed that the liquid impinger provided protection for vegetative bacteria from physical stresses and sunlight. The gravimetric method does not seem suitable for evaluating vegetative cells due to desiccation of bioaerosols by airflow (Wang, Reponen, Grinshpun, Gorny, & Willeke, 2001).
The dominance of Gram-positive bacterial isolates is an indication of inadequate ventilation and overcrowding in the evaluated flourmill (Morey et al., 1986). This finding corresponds with Dutkiewicz et al. (2000) and Abdel Hameed and Khoder (2001) who found bacteria (Bacillus, Corynebacteria, Cocci) and Streptomycetes in airborne organic dust. Moreover, Swan and Crook (1998) found Gram-positive spore-forming Bacillus and Cocci (Curtobacterium, Micrococcus and Staphylococcus) and Gram-negative bacteria including Pseudomonas and Enterobacter spp. in grain dust.
Airborne microbial counts exceeded the proposed value of OEL 5–10 × 103 CFU m−3 of total microorganisms for occupational environments (Malmros, Sigsgaard, & Bach, 1992). In the present study, airborne bacteria and fungi recovered using the AGI sampler at the double roller mill location were found in the range exceeding the proposed value of OEL 1 × 105 CFU m−3 (Gòrny & Dutkiewicz, 2002) for industrial settings contaminated by organic dust. In contrast, Gram-negative bacterial levels did not exceed the proposed values of OEL 1 × 103 CFU m−3 (Clark, 1986). Otherwise the presence of Gram-negative bacteria has occupational hazards. Gram-negative bacteria possess strong allergenic and endotoxinic properties. Endotoxins can cause acute toxic effects, fever, malaise and decreased pulmonary function (Rylander & Jacobs, 1994).
In the present study, the highest degree of airborne actinomycetes pollution was detected in the location with high amounts of dust because they are a group of soil bacteria and are commonly found in fodder, soil and agricultural areas. Actinomycetes are important air biocontaminants in agricultural and waste composting plants (Lacey, 1989). Their presence in the indoor environment is an indicator of contamination (ACGIH, 1989). Swan and Crook (1998) found actinomycetes in the range of 0–1.2 × 103 CFU m−3 during grain handling, which corresponds with the results in the present study. Actinomycete spores are an important risk factor for adverse respiratory health effects because their aerodynamic diameter ranges from 0.7–1.5 μm, which may penetrate deep into the lungs causing allergic alveolitis (Lacey & Crook, 1988) and stimulate lung macrophage reactions, which could lead to inflammation and tissue injury (Hirvonen, Nevalainen, Makkonen, Mönkkönen, & Savolainen, 1997).
Flour milling processes add different allergenic and toxigenic fungal types into the air. A rich diversity of Aspergillus species with varying incidence and distribution were found in the flourmill workplace, A. flavus and A. niger were majority species at all locations. Aspergillus is widespread in the environment where they may colonize grains, leaves and soil. The predominance of Aspergillus and Penicillium is in agreement with Pandit, Singh and Singh (1995) who reported that Aspergillus, Penicillium, Cladosporium and smut were the dominant species in bakeries. Lugauskas, Krikstaponis, & Sveistyte (2004) found a variety of fungal types including: Cladosporium, Alternaria, Geotrichum, Oidiodendron, Rhizopus, Torula, Spegazzinia, Acremonium and Cochliobolus in grain mills. Additionally, Alternaria and Fusarium were dominant in the freshly harvested grain but not the stored ones (Abdel Hameed, 2005).
Alternaria and Fusarium have been shown to be the dominant fungal organisms recovered with grain in the field (Hocking, 2003). However in the different flourmill locations evaluated in the present study Aspergillus, Penicillium and Eurotium were the dominant recovered fungal organisms. This corresponds with Lacey (1980) who reported that, if the water content of the grain is higher, spores of storage fungi Aspergillus, Penicillium and Eurotium species may germinate and grow. The dominance of Aspergillus candidus and A. flavus are an indication of inadequate storage and high water content of grains. The presence of Stachybotrys and Eurotium in the double roller and purifiers is an indication of dampness and high moisture content.
The workers in a flourmill may be exposed to mycotoxin-producing species such as Aspergillus flavus, A. ochraceus and A. versicolor. Therefore workers are at high risk of inhalation of the spores and fungal fragments. Krysinska-Traczyk (1992) reported that the inhalation of large counts of Aspergillus candidus spores caused the organic dust toxic syndrome. Moreover, Aspergillus candidus, A. fumigatus, A. flavus, A. terreus, A. parasiticus, A. clavatus, Eurotium, Penicillium and Trichoderma have been identified as a cause of allergic alveolitis (Lacey & Dutkiewicz, 1994).
Aerodynamic diameter is a critical factor for evaluating respiratory exposure. The size distribution causes difference in the airborne behavior of fungal particles. Allergic rhinitis and asthma can result from exposure to relatively large (>5 μm) fungal spores such as Alternaria species deposited in nasal or thoracic regions of the respiratory system. Allergic alveolitis requires smaller fungal spores (<5 μm) such as Aspergillus and Pernicillium species that can penetrate deep into the alveoli (Burge, 1989; Lacey & Crook, 1988). Fungal spores smaller than 5 μm in diameter can penetrate into the lungs so the likelihood of particle penetration into the workers lungs is high in the flourmill environment.
5 Conclusion
The flourmill is a potential source of organic dust. Data on bioaerosols allow the identification of the critical sites where workers are exposed in the flourmill. Suspended dust exceeded the OEL at all flourmill locations. The storage and double roller units were the worst locations for occupational exposure. Deposited dust contained high microbial levels that could be resuspended into the air adding another human health risk. Allergenic and toxigenic airborne fungi and bacteria were found in the workplace environment. Flourmill workers are consistently exposed to elevated levels and types of bioaerosols that may trigger respiratory disorders. Further health evaluations should be carried out and suitable countermeasures taken to avoid excess biocontamination.
Abbreviations
- CFU/p/h:
-
Colony forming unit per plate per hour
- CFU m−3 :
-
Colony forming unit per cubic meter
- OEL:
-
Occupational exposure limit
- dae:
-
Aerodynamic diameter
- AGI:
-
All-glass impinger
References
Abdel Hameed, A. A. (2005). Vegetation: A source of air fungal contaminant. Aerobiologia, 21, 53–61.
Abdel Hameed, A. A, & Khoder, M. I. (2001). Suspended particulates and bioaerosols emitted from an agricultural non-point source. JEM, 3, 206–209.
Abdel Hameed, A. A., Shakour, A., & Yasser, H. I. (2003). Evaluation of bioaerosols at an animal feed manufacturing industry: A case study. Aerobiologia, 19, 89–95.
American Conference of Governmental Industrial Hygienists, ACGIH. (1989). Step two: on-site investigation, pp. 1–8, fungi, pp. 1–10, Bacteria, pp. 1–7. In Committee on Bioaerosols (Eds.), Guidelines for the assessment of bioaerosols in the indoor environment. Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
Aydogdu, H., Asan, A., Otkum, M.T., & Ture, M. (2005). Monitoring of fungi and bacteria in the indoor air of primary schools in Edirne city, Turkey. Indoor Built Environment, 14(5), 411–425.
Barnett, H. L., & Hunter, B. B. (1999). Illustrated genera of imperfect fungi (4th ed.). St. Paul, MN: The American Phytopathological Society, APS, 218 pp.
Burge, H. (1989). Airborne allergenic fungi: Classification, nomenclature, and distribution. Immunology and Allergy Clinics of North America, 9(2), 307–319.
Chan-Yeung, M., Enarson, D. A., & Kennedy, S. M. (1992). The impact of grain dust on respiratory health. The American Review of Respiratory Disease, 145, 476–487.
Clark, S. (1986). Report on prevention and control. American Journal of Industrial Medicine, 10, 267–273.
Cown, W. B., Kethley, T. W., & Fincher, E. L. (1957). The critical orifice liquid as a sampler for bacterial aerosols. Applied Microbiology, 5, 119–124.
Crook, B., Venables, K. M., Lacey, J., Musk, A. W., & Newman Taylor, A. J. (1988). Dust exposure and respiratory symptoms in a UK bakery. In W. D. Griffiths (Ed.), Aerosol: Their generation, behaviour and application (pp. 341–345). Aerosol Society Second Conference, Aerosol Society, London.
Desai, M. R., & Ghosh, S. K. (2003). Occupational exposure to airborne fungi among rice mill workers with special reference to aflatoxin producing. A. flavus strains. Annals of Agricultural and Environmental Medicine, 10, 159–162.
DeLucca, A. J., Godshall, M. A., & Palmgren, M. S. (1984). Gram-negative bacterial endotoxins in grain elevator dusts. American Industrial Hygiene Association Journal, 45, 336–339.
Dutkiewicz, J. (1978). Exposure to dust-borne bacteria in agriculture. I. Environmental studies. Archives of Environmental Health, 33, 250–259.
Dutkiewicz, J. (1986). Microbial hazards in plants processing grain and herbs. American Journal of Industrial Medicine, 10, 300–302.
Dutkiewicz, J., Kus, L., Dutkiewicz, E., & Warren, C. P. W. (1985). Hypersensitivity pneumonitis in grain farmers due to sensitization to Erwinia herbicola. Annals of Allergy, 54, 65–68.
Dutkiewicz, J., Olenchock, S. A., Sorenson, W. G., Gerencser, V. F., May, J. J., Pratt, D. S., & Robinson, V. A. (1989). Levels of bacteria, fungi and endotoxin in bulk and aerosolized corn silage. Applied and Environmental Microbiology, 55, 1093–1099.
Dutkiewicz, J., Krysiñska-Traczyk, E., Skórska, C., Sitkowska, J., Prażmo, Z., & Urbanowicz, B. (2000). Exposure of agricultural workers to airborne microorganisms and endotoxin during handling of various vegetable products. Aerobiologia, 16, 193–198.
Eduard, W. (1997). Exposure to non-infectious microorganisms and endotoxins in agriculture. Annals of Agricultural and Environmental Medicine, 4, 179–186.
Gòrny, R. L., & Dutkiewicz, J. (2002). Bacterial and fungal aerosols in indoor environment in central and eastern European countries. Annals of Agricultural and Environmental Medicine, 9, 17–23.
Gregory, S. (1963). Statistical methods and geographer (1st ed., pp. 121–184). London: Longmans.
Hirvonen, M. R., Nevalainen, A., Makkonen, M., Mönkkönen, J. & Savolainen, K. (1997). Streptomycetes spores from mouldy houses induce nitric oxide, TNFx and IL-6 secretion from RAW264.7 macrophage cell line without causing subsequent cell death. Environmental Toxicology and Pharmacology, 1, 57–63.
Hocking, A. D. (2003). Microbiological facts and fictions in grain storage. In E. J. Wright, M. C Webb, & E. Highley (Eds.), Stored grain in Australia. Proceedings of the Australian Postharvest Technical Conference, Canberra, 25–27 June, 2003. CSIRO Stored Grain Research Laboratory, Canberra.
Jensen, P. A., Lighthart, B., Mohr, A. J., & Shaffer, B. T. (1994). Instrumentation used with microbial bioaerosol. In B. Lighthart & A. J. Mohr (Eds.), Atmospheric microbial aerosol theory and applications (pp. 226–284). New York, NY: Chapman and Hall.
Jothish, P. S., & Nayar, T. S. (2004). Airborne fungal spores in a sawmill environment in Palakkad district, Kerala, India. Aerobiologia, 20, 75–81.
Karpinski, E. A. (2003). Exposure to inhalable dust in Canadian flourmill. Applied Occupational and Environmental Hygiene, 18(12), 1022–1030.
Krysinska-Traczyk, E. (1992). Oceno znaczenia gatunku Aspergillus candidus jako czynnika narazenia zawodowego w rolnictwie na podstawie badan aerobiologicznych I immunologogicznych. Med Wiejska, 27, 131–141.
Lacey, J. (1980). The microflora of grain dusts. In J. A. Dosman & D. J. Cotton (Eds.), Occupational pulmonary disease: Focus on grain dust and health (pp. 189–200). London: Academic Press Inc.
Lacey, J. (1989). In S. T. William, M. E. Sharpe, & J. G. Holt (Eds.), Bergey’s Manual of Systematic Bacteriology (Vol. 4, pp. 2573–2585). Baltimore, M.D: Williams and Wilkins.
Lacey, J., & Crook, B. (1988). Review: Fungal and actinomycetes spores as pollutants of the workplace and occupational allergens. The Annals of Occupational Hygiene, 32(4), 515–533.
Lacey, J., & Dutkiewicz, J. (1994). Bioaerosols and occupational lung disease. Journal of aerosol science, 25, 1371–1404.
Lugauskas, A., Krikstaponis, A., & Sveistyte, L. (2004). Airborne fungi in industrial environments—potential agents of respiratory diseases. Annals of Agricultural and Environmental Medicine, 11, 19–25.
Macher, J., Chatigny, M., & Burge, H. (1995). Sampling airborne microorganisms and aeroallergens. In B. Cohen & S. Hering (Eds.), Air sampling instruments for evaluation of atmospheric contaminants (8th ed., pp. 589–617). Cincinnati, OH: ACGIH.
Malmberg, P., Rask-Andersen, A., Lundholm, M., & Palmgren, U. (1990). Can spores from molds and actinomycetes cause an organic dust toxic syndrome reaction? American Journal of Industrial Medicine, 17, 109–110.
Malmros, P., Sigsgaard, T., Bach, B. (1992). Occupational health problems due to garbage sorting. Waste Management and Research, 10, 227–234.
Meo, S. A. (2004). Dose responses of years of exposure on lung functions in flourmill workers. Journal of Occupational Health, 46, 187–191.
Morey, P., Otten, J., Burge, H., Chatingy, M., Feeley, J., LaForce, F. M., & Peterson, K. (1986). Airborne viable microorganisms in office environments: sampling protocol and analytical procedures. Applied Industrial Hygiene, 1, R19–R23.
Musk, A. W., Venables, K. M., Crook, B., Nunn, A. J., Hawkins, R., Crook, G.D., Graneek, B. J., Tee, R. D., Farrer, N., Johnson, D. A., Gordon, D. J., Darbyshire, J. H., & Newman Taylor, A. J. (1989). Respiratory symptoms, lung function and sensitization to flour in a British bakery. British Journal of Industrial Medicine, 46, 636–642.
Narayn, M. C. J., Ravichandran, V., & Sullia, S. B. (1982). Aeromycology of the atmosphere of Malleswaram market, Bangalore. Acta Botanica Indica, 10, 196–200.
Nieuwenhuijsen, M. J., Sandiford, C. P., Lowson, D., Tee, R. D., Venables, K. M., McDonald, J.C., & Newman Taylor, A. J. (1994). Dust and flour aeroallergen exposure in flourmills and bakeries. Occupational and Environmental Medicine, 51(9), 584–588.
Olenchock, S. A. (1990). Endotoxin in various work environments in agriculture. Developments in Industrial Microbiology, 13, 193–197.
Pandit T., Singh S., & Singh A. B. (1995). Prevalence of culturable and non-culturable airborne fungi in grain store in Delhi. Aerobiologia, 11, 177–182.
Pelczar, M. J., Chan, E. C. S., & Krieg, N. R. (1993). Microbiology: Concepts and applications. New York: Mc Graw Hill Inc., 966 pp.
Rylander, R. (1994). Organic dusts and lung diseases: The role of inflammation. Annals of Agricultural and Environmental Medicine, 1, 7–10.
Rylander, R., & Jacobs, R. R. (1994). Organic dusts, exposure, effects and prevention. Boca Raton, FL: CRC Press, Inc.
Singh A., & Sing A. B. (1994). Airborne fungi in a bakery and the prevalence of respiratory dysfunction among workers. Grana, 33, 349–358.
St-Germain, G., & Summerbell, R. (1996). Identifying filamentous fungi. A clinical laboratory handbook. Belmont: Star Publishing Co.
Sumi, Y., Takeuchi, M., Miyakawa, M., & Nagura H. (1994). Granulomatous lesions in lung induced by inhalation of mold spores. Virchows Archives, 424(6), 661–668.
Surekha, M., Krishnareddi, V., & Reddi, S. M. (1996). Aeromycoflora of poultry shed in relation to incidence of mycotoxigenic fungi. Journal of Palynology, 32, 135–141.
Swan, J. R. M., & Crook, B. (1998). Airborne microorganisms associated with grain handling. Annals of Agricultural and Environmental Medicine, 5, 7–15.
Szponar, B., & Larsson, L. (2001). Use of mass-spectrometry for characterizing microbial communities in bioaerosols. Annals of Agricultural and Environmental Medicine, 8, 111–117.
Taytard, A., Tessier, J. F., Vergeret, J., Pellet, F., Faugere, J. G., Gachie, J. P., Beziau, F., kombou, L., Fontan, J., Redon, S., Rio, P., & Freour, P. (1988). Respiratory function in flourmill workers. European Journal of Epidemiology, 4(10), 104–109.
Vanderzent, C., & Nickelson, R. (1969). A microbiological examination of muscle tissue of beef, pork and lamb carcasses. Journal of Milk and Food Technology, 32, 357–361.
Waksman, S. A. (1967). Actinomycetes. New York: The Ronald Press Company.
Wang, Z., Reponen, T., Grinshpun, S. A., Gorny, R. L., & Willeke, K. (2001). Effect of sampling time and air humidity on bioefficiency of filter samplers for bioaerosol collection. Journal of Aerosol Science, 32, 661–674.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Awad, A.H.A. Airborne dust, bacteria, actinomycetes and fungi at a flourmill. Aerobiologia 23, 59–69 (2007). https://doi.org/10.1007/s10453-007-9049-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10453-007-9049-z