Abstract
Capture of CO2 from flue gas streams using adsorption processes must deal with the prospect of high humidity streams containing bulk CO2 as well as other impurities such as SO x , NO x , etc. Most studies to date have ignored this aspect of CO2 capture. In this study, we have experimentally examined the capture of CO2 from a 12% synthetic flue gas stream at a relative humidity of 95% at 30 °C. A 13X adsorbent was used and the migration of the water and its subsequent impact on capture performance was evaluated. Binary breakthrough of CO2/water vapor was performed and indicated a significant effect of water on CO2 adsorption capacity, as expected. Cyclic experiments indicate that the water zone migrates a quarter of the way into the column and stabilizes its position so that CO2 capture is still possible although decreased. The formation of a water zone creates a “cold spot” which has implications for the system performance. The recovery of CO2 dropped from 78.5% to 60% when moving from dry to wet flue gas while the productivity dropped by 22%. Although the concentration of water leaving the bed under vacuum was 27%(vol), the low vacuum pressure prevented condensation of water in this stream. However, the vacuum pump acted as a condenser and separator to remove bulk water. An important consequence of the presence of a water zone was to elevate the vacuum level thereby reducing CO2 working capacity. Thus although there is a detrimental effect of water on CO2 capture, long term recovery of CO2 is still possible in a single VSA process. Pre-drying of the flue gas steam is not required. However, careful consideration of the impact of water and accommodation thereof must be made particularly when the feed stream temperature increases resulting in higher feed water concentration.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Abbreviations
- L :
-
Length of bed (mm)
- P :
-
Pressure (kPa)
- T :
-
Temperature (°C)
- Z :
-
Dimensionless distance
- u :
-
Interstitial velocity (mm/s)
- t :
-
Time (s)
- z :
-
Axial distance along adsorption bed (mm)
- τ :
-
Dimensionless time
References
Ahn, H., Lee, C.-H.: Effects of capillary condensation on adsorption and thermal desorption dynamics of water in zeolite 13X and layered beds. Chem. Eng. Sci. 59, 2727–2743 (2004)
Carter, J.W., Husain, H.: The simultaneous adsorption of carbon dioxide and water vapor by fixed beds of molecular sieves. Chem. Eng. Sci. 29, 267–273 (1974)
Chang, C.H., Stonesifer, G.T., Cusick, R.J., Hart, J.M.: Comparison of metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems. In: 21st International Conference on Environmental Systems, San Francisco, pp. 1–10 (1991)
Chue, K.T., Kim, J.N., Yoo, Y.J., Cho, S.H., Yang, R.T.: Comparison of activated carbon and zeolite 13X for CO2 recovery from flue gas by pressure swing adsorption. Ind. Eng. Chem. Res. 34, 591–598 (1995)
Kikkinides, E.S., Yang, R.T., Cho, S.H.: Concentration and recovery of CO2 from flue gas by pressure swing adsorption. Ind. Eng. Chem. Res. 32, 2714–2720 (1993)
Ko, D., Siriwardane, R., Biegler, L.T.: Optimization of a pressure-swing adsorption process using zeolite 13X for CO2 sequestration. Ind. Eng. Chem. Res. 42, 339–348 (2003)
Kumar, R., Huggahalli, M., Deng, S., Andrecovich, M.: Trace impurity removal from air. Adsorption 9, 243–250 (2003)
Lee, J.S., Kim, J.H., Kim, J.T., Suh, J.K., Lee, J.M., Lee, C.H.: Adsorption equilibria of CO2 on zeolite 13X and zeolite X/Activated carbon composite. J. Chem. Eng. Data 47, 1237–1242 (2002)
Mellow, M., Eić, M.: Adsorption of sulfur dioxide from pseudo binary mixtures on hydrophobic zeolites: modeling of the breakthrough curves. Adsorption 8, 279–289 (2002)
Rege, S.U., Yang, R.T., Buzanowski, M.A.: Sorbents for air prepurification in air separation. Chem. Eng. Sci. 55, 4827–4838 (2000)
Rege, S.U., Yang, R.T., Qian, K., Buzanowski, M.A.: Air-prepurification by pressure swing adsorption using single/layered beds. Chem. Eng. Sci. 56, 2745–2759 (2001)
Shen, C.M., Worek, W.M.: Cosorption characteristics of solid adsorbents. J. Heat Mass Transf. 37, 2123–2129 (1994)
Watson, C.F., Whitley, R.D., Meyer, M.L.: Multiple zeolite adsorbent layers in oxygen separation. U.S. Patent, US005529610A, to Air Products and Chemicals, Inc. (1996)
Wilson, S.J., Beh, C.C.K., Webley, P.A., Todd, R.S.: The effects of a readily adsorbed trace component (water) in a bulk separation PSA process: the case of oxygen VSA. Ind. Eng. Chem. Res. 40, 2702–2713 (2001)
Zhang, J., Webley, P., Xiao, P.: Experimental pilot-scale study of carbon dioxide recovery from flue gas streams by vacuum swing adsorption. In: AIChE 2005 Annual Meeting, Cincinnati (2005)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Li, G., Xiao, P., Webley, P. et al. Capture of CO2 from high humidity flue gas by vacuum swing adsorption with zeolite 13X. Adsorption 14, 415–422 (2008). https://doi.org/10.1007/s10450-007-9100-y
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10450-007-9100-y