Abstract
The feasibility of using novel electromagnetic wave sensors for real-time monitoring of metal pollution in water was assessed. Five solutions with different concentrations of lead (0, 1, 10, 50, 100 mg/L) were measured using several sensing methods: UV–Vis spectroscopy, low frequency capacitance and resistance measurements, and two sensing systems based on microwave technology. With this last approach, two sensing devices were used: a resonant cavity and a planar sensor with gold interdigitated electrode design printed on a PTFE substrate with a protective PCB lacquer coating. Results confirmed the ability of these systems to quantify the lead concentration as changes in spectrum signal at specific frequencies of the electromagnetic spectrum. Spectra were unique, with clearly observed shifts in the resonant frequencies of the sensors when placed in direct contact with different lead solutions, demonstrating the possibility of continuous monitoring with great sensitivity, selectivity, and high spatial and temporal resolution. Consequently, determination of trace and toxic metals using microwave spectroscopy is a promising alternative to traditional grab-sampling and laboratory based analyses. On-line and continuous monitoring of real-time metal concentrations offers the potential for a more effective emergency response and the platform for better scientific understanding and remediation of contaminated mine drainage.
抽象
文章评价一种利用电磁波传感器实时监测水中金属污染新型方法。使用几种传感方法,包括紫外可见吸收光谱、低频电容电阻测量和双传感微波装置,测量了五种已知铅浓度溶液(分别为0、1、10、50和100 mg/L)。最后一种方法采用双传感系统:一个谐振腔和一个平面传感器,金指状交叉电极印制于聚四氟乙烯(PTFE)底片,覆盖保护性印制电路板(PCB)膝涂层。结果证实:该系统可依据特定电磁波谱频段内的波谱信号变化来量化铅浓度。波谱是唯一的,当谐振传感器被直接放入不同铅浓度溶液时,可清楚观察到谐振频率迁移,表明该方法具有高敏感性、选择性和高时空分辨率的连续监测能力。因此,除传统取样和实验室测试金属浓度以外,微波频谱是另一种有潜力的测量微量元素或有毒元素浓度的方法。在线和连续实时监测金属浓度为高效应急响应、高水平科研平台搭建和矿井废水处理提供了更广的发展前景。
Zusammenfassung
Die Anwendbarkeit von elektromagnetischen Sensoren zur Echtzeitüberwachung der Metallbelastung von Wässern wurde überprüft. Fünf Lösung mit verschiedenen Bleikonzentrationen (0, 1, 10, 50, 100 mg/L) wurden mit verschiedenen Methoden gemessen: UV-Vis-Spektroskopie, Niederfrequenzkapazitäts- und Widerstandsmessungen und zwei auf Mikrowellentechnologie basierende Sensorsysteme. Für letztere wurden zwei Messgeräte genutzt: ein Resonanzhohlraumsensor und ein Flächensensor mit Gold-Interdigitalstruktur, aufgedampft auf ein PTFE-Substrat mit einer PCB-Schutzschicht. Die Ergebnisse bestätigten die Eignung dieser Systeme, die Bleikonzentration als Änderungen des Spektrumsignals bei spezifischen Frequenzen quantitativ zu bestimmen. Im direkten Kontakt mit verschiedenen Bleilösungen zeigten die Sensoren eindeutige sowie deutliche Ausschläge der Resonanzfrequenzen. Damit bieten diese die Möglichkeit der kontinuierlichen Überwachung mit einer großen Empfindlichkeit, Selektivität und einer hohen räumlichen und zeitlichen Auflösung. Die Bestimmung von Spurenmetallen und toxischen Metallen mittels Mikrowellenspektroskopie stellt damit eine vielversprechende Alternative zur herkömmlichen Probenahme mit anschließender Laboranalyse dar. Die Online- und Echtzeitüberwachung von Metallkonzentrationen bietet die Möglichkeit eines effektiveren Notfallschutzes sowie die Plattform für ein besseres wissenschaftliches Verständnis und die Behandlung von belasteten Grubenwässern.
Resumen
Se analizó la factibilidad de utilizar sensores electromagnéticos para el monitoreo en tiempo real de la polución del agua por metales. Cinco soluciones con diferentes concentraciones de plomo (0, 1, 10, 50, 100 mg/L) se midieron usando varios métodos: espectroscopía UV-Vis, capacitancia de baja frecuencia y mediciones de resistencia y dos sensores basados en tecnología de microondas. Con esta última aproximación, se usaron dos instrumentos distintos: una cavidad resonante y un sensor plano con electrodo de oro interdigitado impreso en un sustrato PTFE con un revestimiento protector de laca PCB. Los resultados confirmaron la capacidad de estos sistemas para cuantificar la concentración de plomo como cambios en la señal espectral a frecuencias específicas del espectro electromagnético. Los espectros fueron únicos con picos claros en las frecuencias resonantes de los sensores cuando se ubican en contacto directo con las soluciones de diferentes concentración en plomo, demostrando la posibilidad de un continuo monitoreo con buena sensibilidad, selectividad y alta resolución espacial y temporal. Consecuentemente, la determinación de metales tóxicos usando espectroscopía de microondas es una alternativa promisoria a la toma de muestra y el análisis de laboratorio. El monitoreo continuo y en línea ofrece la potencialidad de una respuesta más efectiva en emergencias y la plataforma para una mejor comprensión y remediación de los drenajes de mina contaminados.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Mining can have a significant environmental impact, especially due to the presence of waste materials abandoned in waste heaps (Byrne et al. 2012; Hudson-Edwards 2016). Point and diffuse sources determine the dispersion into the environment of toxic inorganic pollutants, mainly metals (Cd, Pb, Cu, Zn, Ni, Fe, etc.), a process driven largely by the oxidation and subsequent hydrolysis of metal sulphides. Typically, mine waters have a clear correlation between low pH, metal, and sulphate content. This phenomenon, known as acid mine drainage (AMD), has been described as the biggest environmental problem associated with mines (Younger et al. 2002). Therefore, adequate monitoring and assessment is required to minimise the environmental risk posed by AMD from active and abandoned mining sites all over the world.
Assuring a high quality of water and protecting it from chemical contamination is a major sustainable development goal. In the UK, according to the Environment Agency (2008), 9% of the rivers in England and Wales, and 2% in Scotland fail environmental standards because of contaminated drainage from more than 3000 abandoned metal mines. The Mineral Policy Center (Lyon et al. 1993) estimated that 557,650 abandoned mines in the USA are polluting over 19,000 km of the nation’s waterways. Implementation of the European Water Framework Directive and US Clean Water Act requires new methods and systems to be able to monitor water resources in real-time, with low cost and easy maintenance (Allan et al. 2006; Brack et al. 2017). The Agency for Toxic Substances and Disease Registry (ATSDR), places lead in second position in its substance priority list.
Lead concentrations in mine water range from < 0.01 to 12 mg/L (Byrne et al. 2012); however, concentrations in excess of this may not be uncommon where evaporation causes concentration of metals. The UKTAG established an environmental quality standard (EQS) for dissolved Pb in surface water of 7.2 ppb (Rowland et al. 2011). Generally, the ionic form of Pb (Pb2+) is considered most toxic. However, other weakly complexed species (oxides, hydroxides, and sulphates) are also cause for concern. Lead exists primarily in its ionic form at pH < 4 and will precipitate or sorb to other phases as the pH increases (Smith 1999).
Trace contaminants in polluted watersheds are normally measured by laboratory analysis of grab samples: mostly anions are detected by ion chromatography (IC) and cations (including metals) by spectroscopy: AAS (atomic absorption spectroscopy), ICP-OES (inductively coupled plasma—optical emission spectrometry), ICP-MS (inductively coupled plasma—mass spectrometry) and INAA (instrument neutron activation analysis) (Yang et al. 2010). These methods present several advantages, including high sensitivity, low detection limits, and the opportunity to detect many trace metals simultaneously. However, they also have several drawbacks: they require a constant supply of costly chemicals and a well-trained staff for reliable operation, and they cannot provide in-situ and real-time data, which limits our ability to monitor and manage remote sites and to detect the immediate effects of accidental or unexpected contamination events.
The need for on-line monitoring has sparked the development of various remote detection and smart monitoring systems (Mukhopadhyay and Mason 2015). To address this, a research group from the Built Environment and Sustainable Technologies (BEST) Research Institute at the Liverpool John Moores University has developed a novel sensing system based on electromagnetic (EM) wave techniques for real-time detection of changes in materials across a range of industrially relevant applications. The real-time nature of the measurements and potentially portable sensor size makes this approach a viable alternative to mainly lab-based methods of health and safety (Mason et al. 2014c) and quality control in the food industry (Joshi et al. 2016; Korostynska et al. 2013a; Mason et al. 2016), in aquaculture (Korostynska et al. 2015; Nakouti et al. 2014) and environment (Korostynska et al. 2014a; Mason et al. 2014a, 2014b). The principle is based on the interaction of propagating or resonating EM modes within the material being tested. By considering how reflected microwave signals vary at discrete frequency intervals, the changes in the signal can be linked to the amount and type of sample being tested. Research (Korostynska et al. 2013b, 2014b, c) has confirmed the potential of a novel microwave sensor for water analysis, observing changes in the microwave part of the electromagnetic spectrum depending on the materials being analysed. Such work has laid the foundations for new methods, based on EM sensors, for qualitatively and quantitatively determining metal concentrations in mining areas.
Several other technologies have been recently developed as alternatives to traditional grab sampling and laboratory analysis. For example, the problem of sampling rate and sample preparation (filtration and acidification) can be solved using auto-sampling equipment, but this can introduce error into measurements and reduce one’s ability to determine a significant event because of the sampling frequency. This last issue has been addressed by Chapin (2015) who developed a water sampler, the MiniSipper, able to acidify, filter, and grab water samples at a high frequency, thanks to its capacity to grab up to 250 five mL samples. It uses gas bubbles to separate small sample amounts (for ICP-MS analysis) in a long tubing coil. This approach is advantageous for detecting an unexpected event (due to its capability to collect samples with high frequency), for its capacity to prepare samples directly in the field for analysis in laboratory, and for improving our understanding of the geochemical response to temporally variable processes. However, this method is not able to reduce the high costs of laboratory analysis.
Various technologies offering in-situ and on-line monitoring capability are in development, offering particular advantages for surveillance and early warning (O’Flynn et al. 2010), and several of these are potentially attractive for on-site wastewater quality monitoring (Korostynska et al. 2013c). This includes analysing metal contaminants in wastewater using: biosensors (Eltzov et al. 2015), optical systems (Gómez-de Pedro et al. 2014) and electrochemical techniques (Bansod et al. 2017). However, further work is needed to develop simple, reliable, and cost-effective techniques for remote detection of pollutants, to better understand processes that regulate metal dispersion and allow for an emergency response to unexpected events (Byrne et al. 2013; Cidu et al. 2011; Jones et al. 2013; Lynch et al. 2017). No single system available today can fully meet the needs to determine, in real-time, the composition of water to the desired sensitivity level and cost-effectiveness for effective remediation and long-term monitoring of water bodies affected by metal mine drainage.
The aim of this study was to assess and compare the use of the new sensor system for detecting changes in Pb concentrations in mining-affected water. Spectrum responses for four properties (absorbance, capacitance, resistance, and reflected power) at three frequency ranges were monitored and analysed. This will allow us to improve the features of these sensing systems to simultaneously analyse a range of metals at low concentrations, allowing for continuous in-situ monitoring, thus solving the limitations of lab-based technologies.
Materials and Methods
Samples Preparations
Five samples of lead at different concentrations (0, 1, 10, 50, 100 mg/L) were prepared using different volumes of Pb 1000 ppm ICP standard solution certified (Sigma 41318) dissolved in deionised water in a 50 mL volumetric flask. Each sample was acidified with 1% nitric acid (analytical grade, 67%) to avoid precipitation. Samples were placed in high-density polyethylene bottles. All prepared standards produced clear solutions. All measurements were performed in an air-conditioned environment at a constant temperature of 18 °C.
Measurement Methods
In this work, optical, electrical, and microwave properties of lead solutions were detected at separate frequency ranges of the EM spectrum. The following techniques were used:
-
Optical absorbance, measured between 200 and 1000 nm using a UV–Vis spectrophotometer (Jenway 7315) with 3.5 mL sample size;
-
Microwave reflected power (S11), between 10 and 15 GHz using a vector network analyser (Rohde & Schwarz VNA 24), with 15 mL and 400 µL sample sizes for the resonant cavity and 8-pair interdigitated electrode (IDE) device, respectively;
-
Resistance (Rp) and capacitance (Cp) between 20 and 200 kHz (with impedance ranging from 1 to 25 Ω) using a programmable LCR bridge (L = inductance; C = capacitance; R = resistance; Hameg 8118), requiring a 400 µL sample size.
All samples were measured five times with each method to assess repeatability. The spectrophotometer technique used a standard cuvette to enable exposure of the sample to light, and the LCR meter made use of an open-ended coaxial probe.
The microwave measurements made use of two sensors: a resonant cavity (Fig. 1) and a gold eight-pair IDE pattern printed on a planar polytetrafluoroethylene (PTFE) substrate with a PCB lacquer coating (Fig. 2). The coating was added to prevent short-circuiting when the sensor was exposed to the sample. Both sensors were designed so as to limit the samples’ position and volume, which makes it possible to detect small changes in sample composition. These changes can be related to the composition of the materials and/or their relative concentrations (Mason et al. 2016).
Spectra measured with the resonant cavity and IDE sensor were recorded for air and five concentrations of lead, demonstrating the dissimilar output of the sensor for different kind of samples. Moreover, to evaluate the reproducibility of the method, four different IDE sensors were simultaneously tested using four different channels to measure the reflected power (Fig. 3). Results obtained using the described measurement techniques were used as an indicator of lead content. Results were analysed using Excel, OriginPro9, and Curve expert Basic 1.4. Best-fit curves for different Pb concentrations at specific frequencies of the EM spectrum were evaluated using the coefficient of determination (R2), equal to the square of the Pearson correlation, which corresponds to the covariance of two variables divided by the product of their standard deviations.
Results and Discussion
Absorbance
Absorbance spectra between 200 and 350 nm (UV) are shown in Fig. 4a, and represent the only area of the measured optical spectra where significant variation in absorbance occurred with varied lead concentrations. The chemical information given by an absorption spectrum is contained in the position and intensities of the absorption band. It is clearly visible that the absorbance is related to the Pb concentration, particularly at the 300 nm peak. Linear correlations at two wavelengths, 247 and 300 nm, are shown in Fig. 4b, with high correlation in both cases (R2 equals 0.9757 and 0.9869, respectively).
Capacitance and Resistance
Capacitance and resistance magnitude results were used, in combination with optical and microwave responses, for sensor evaluation. Correlations between Cp, Rp and Pb content are shown, respectively, in Figs. 5 and 6. It is clear that these parameters changed with the Pb concentration. In fact, high linear correlation with Pb concentration was identified for both parameters: for Cp, where R2 = 0.79 at 30 Hz and R2 = 0.95 at 6 kHz; for Rp, with R2 = 0.9869 at 180 Hz and R2 = 0.9757 at 200 kHz.
Microwave Sensing
The response for the microwave sensor is given in dBm, and demonstrates a shift in amplitude correspondent at different frequencies to the concentration of lead in each sample. After each measurement, responses returned to the original position (air spectra), confirming that the developed resonant cavity and microwave sensors are reliable and reusable, and thus a sustainable solution for continuous water quality monitoring.
The resonant cavity demonstrated the capability for its output to change (see Fig. 7, which illustrates the raw signal output of the sensor) as a result of the five different Pb concentrations. Figure 8 shows good correlation (with R2 = 0.9527 and R2 = 0.9017) between the concentration and changes in output at two frequencies, 415 MHz and 2.45 GHz, after processing of the raw data. This gives confidence that the technique is an attractive option for real-time detection of metals in water.
The microwave spectrum in the frequency range 500 MHz–15 GHz obtained by measurements with the IDE sensor is shown in Fig. 9. During the measurements, significant pronounced resonant peak shifts were noticed when the different samples were placed in contact with the sensor pattern. This shift was more evident when the samples had a higher concentration of Pb. This is clearly visible in several parts of the spectrum, in particular between 300 MHz and 3 GHz. The shift in the spectrum with the best linear correlation among the Pb samples was in the frequency range of 2.3–2.65 GHz (shown in the red rectangle in Fig. 9 and magnified in Fig. 10). The correlations between reflected power and Pb concentration in each of 60.000 points of the frequency range 10 MHz–10 GHz, were calculated with the square of Pearson’s correlation using Excel. In this way, it was found that the best correlation was at 2.3952 GHz with R2 = 0.9982 (R2 = 0.978 in the peak at 2.4909 GHz). Statistical features, namely R2, sensitivity, and RSD (relative standard deviation), obtained by measuring these four properties with the described techniques are summarised in Table 1.
Future Work
Despite many recent technological advances, significant work remains to be accomplished before a reliable smart sensor for water quality monitoring is achievable. In this study, we measured moderate to high Pb concentrations in deionised water in lab samples at specific frequencies of the EM spectrum. Real mine water is more complex and characterised by high levels of dissolved metals and sulphate and, frequently, low pH.
Therefore, the next step is to expand from the single metal analysis performed in this study to multi-element analysis and to the lower concentrations (< 1 mg/L) more commonly found in watercourses receiving mine drainage and natural dilution. Although there are obviously several challenges that must be overcome before this technology can ensure that measurements correctly identify distinct contaminants, despite their possible interference with each other, this paper clearly shows the feasibility of the proposed approach. Each spectrum contains 60,000 points, and by analysing the response at each point for different concentrations, metals, and water composition, it appears that this methodology could more accurately characterize multi-contaminant concentrations. We hypothesize that the microwave sensors presented in this paper can be the prototype for a smaller, portable, online system capable of monitoring pollution in mining areas. This sensing technology could provide continuous verification of water quality and safety, and provide immediate warning of contamination episodes or water quality guideline threshold breaches. Moreover, this methodology offers the potential to reduce analytical costs by combining wireless sensing systems to provide continuous, in situ remote monitoring, thus facilitating the targeted treatment of mining-affected waters. It could also offer the ability for in-situ, real-time monitoring and reporting of water quality over large, remote geographical areas and provide an early warning system for pollution events. The great challenge will be to develop sensors with different substrates and coatings to assess the wide range of water pollutants and to test them in the field for their selectivity and sensitivity.
Conclusions
Electromagnetic wave sensors that operate at microwave frequencies can be used to determine Pb concentrations by producing EM wave spectra specific to this element, which was shown by variations in signal amplitude at distinct frequencies. The unique response shown from each sample and each sensor produced resonant peaks at difference frequencies, making the sensors a potentially attractive option for real-time monitoring of many contaminants. The developed sensors could be remotely operated with appropriate wireless hardware, and could be physically small, which would allow continuous real-time monitoring and subsequent mitigation of waterway pollution. Such on-line monitoring of real-time metal concentrations offers the possibility of more effective emergency response activities and remediation of contaminated mine drainage.
References
Allan IJ, Vrana B, Greenwood R, Mills GA, Knutsson J, Holmberg A, Guigues N, Fouillac A, Laschi S (2006) Strategic monitoring for the European Water Framework Directive. Trends Anal Chem 25:704–715
Bansod B, Kumar T, Thakur R, Rana S, Singh I (2017) A review on various electrochemical techniques for heavy metal ions detection with different sensing platforms. Biosens Bioelectron 94:443–455
Brack W, Dulio V, Ågerstrand M, Allan I, Altenburger R, Brinkmann M, Bunke D, Burgess RM, Cousins I, Escher BI, Hernández FJ, Hewitt LM, Hilscherová K, Hollender J, Hollert H, Kase R, Klauer B, Lindim C, López Herráez D, Miège C, Munthe J, O’Toole S, Posthuma L, Rüdel H, Schäfer RB, Sengl M, Smedes F, van de Meent D, van den Brink PJ, van Gils J, van Wezel AP, Vethaak AD, Vermeirssen E, von der Ohe PC, Vrana B (2017) Towards the review of the European Union Water Framework management of chemical contamination in European surface water resources. Sci Total Environ 576:720–737
Byrne P, Wood PJ, Reid I (2012) The impairment of river systems by metal mine contamination: a review including remediation options. Crit Rev Environ Sci Technol 42:2017–2077
Byrne P, Reid I, Wood PJ (2013) Stormflow hydrochemistry of a river draining an abandoned metal mine: the Afon Twymyn, central Wales. Environ Monit Assess 185:2817–2832
Chapin TP (2015) High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers. Appl Geochem 59:118–124
Cidu R, Frau F, Da Pelo S (2011) Drainage at abandoned mine sites: natural attenuation of contaminants in different seasons. Mine Water Environ 30:113–126
Eltzov E, Yehuda A, Marks RS (2015) Creation of a new portable biosensor for water toxicity determination. Sens Actuator B 221:1044–1054
Environment Agency (2008) Abandoned mines and the water environment. Science report—SC030136-S41. Environmental Agency, Bristol
Gómez-de Pedro S, Lopes D, Miltsov S, Izquierdo D, Alonso-Chamarro J, Puyol M (2014) Optical microfluidic system based on ionophore modified gold nanoparticles for the continuous monitoring of mercuric ion. Sens Actuator B 194:19–26
Hudson-Edwards K (2016) Tackling mine wastes. Science 352:288–290
Jones A, Rogerson M, Greenway G, Potter HAB, Mayes WM (2013) Mine water geochemistry and metal flux in a major historic Pb-Zn-F orefield, the Yorkshire Pennines, UK. Environ Sci Poll Res 20:7570–7581
Joshi KH, Mason A, Shaw A, Korostynska O, Cullen JD, Al-Shamma’a A (2016) Online monitoring of milk quality using electromagnetic wave sensors. Proceedings international conference on sensing technology, pp 700–705
Korostynska O, Blakey R, Mason A, Al-Shamma’a A (2013a) Novel method for vegetable oil type verification based on real-time microwave sensing. Sens Actuator A 202:211–216
Korostynska O, Mason A, Al-Shamma’a AI (2013b) Flexible microwave sensors for real-time analysis of water contaminants. J Electromag Wave 27:2075–2089
Korostynska O, Mason A, Al-Shamma’a AI (2013c) Monitoring pollutants in wastewater: traditional lab based versus modern real-time approaches. In: Mukhopadhyay SC, Mason A (eds) Smart sensors for real-time water quality monitoring. Springer, Berlin, pp 1–24
Korostynska O, Mason A, Al-Shamma’a A (2014a) Microwave sensors for the non-invasive monitoring of industrial and medical applications. Sens Rev 34:182–191
Korostynska O, Mason A, Ortoneda-Pedrola M, Al-Shamma’a A (2014b) Electromagnetic wave sensing of NO3 and COD concentrations for real-time environmental and industrial monitoring. Sens Actuator B 198:49–54
Korostynska O, Ortoneda-Pedrola M, Mason A, Al-Shamma’a AI (2014c) Flexible electromagnetic wave sensor operating at GHz frequencies for instantaneous concentration measurements of NaCl, KCl, MnCl2 and CuCl solutions. Measure Sci Technol 25(6):5105–5111
Korostynska O, Mason A, Al-Shamma’a A, Jansomboon W, Boontanon S (2015) Real-time detection of residual antibiotics concentration with microwave cavity and planar EM sensors. Proceedings 9th international conference on sensing technology, pp 492–495
Lynch SFL, Batty LC, Byrne P (2017) Critical control of flooding and draining sequences on the environmental risk of Zn-contaminated riverbank sediments. J Soils Sediments 17:2691–2707
Lyon LS, Hilliard TJ, Bethell TN (1993) Burden of Gilt. Mineral Policy Center, Washington
Mason A, Korostynska O, Wylie S, Al-Shamma’a AI (2014a) Non-destructive evaluation of an activated carbon using microwaves to determine residual life. Carbon 67:1–9
Mason A, Osaza K, Korostynska O, Nakouti I, Ortoneda-Pedrola M, Maeda M, Al-Shamma’a A (2014b) Electromagnetic wave sensing of Euglena gracilis viability and quantification. In: Proceedings, 3rd international conference on materials and applications for sensors and transducers, pp 432–436
Mason A, Wylie S, Korostynska O, Cordova-Lopez LE, Al-Shamma’a AI (2014c) Flexible e-textile sensors for real-time health monitoring at microwave frequencies. Int J Smart Sens Intel Syst 7:31–47
Mason A et al (2016) Theoretical basis and application for measuring pork loin drip loss using microwave spectroscopy. Sensors (14248220) 16:1–13. https://doi.org/10.3390/s16020182
Mukhopadhyay SC, Mason A (eds) (2015) Smart sensors for real-time water quality monitoring. Springer, Heidelberg
Nakouti I, Korostynska O, Mason A, Al-Shamma’a AI (2014) Detection of pathogenic bacteria in aqueous media: assessing the potential of real-time electromagnetic wave sensing. Proceedings, 8th international conference on sensing technology, pp 140–145
O’Flynn B, Regan F, Lawlor A, Wallace J, Torres J, O’Mathuna C (2010) Experiences and recommendations in deploying a real-time, water quality monitoring system. Measure Sci Technol 21(12):4004–4014
Rowland P, Neal C, Sleep D, Vincent C, Scholefield P (2011) Chemical quality status of river for the water framework directive: a case study of toxic metals in North West England. Water 3:649–666
Smith KS (1999) Metal sorption on mineral surfaces: an overview with examples relating to mineral deposits. In: Plumlee GS, Logsdon MJ (eds) The environmental geochemistry of mineral deposits, Part A: processes, techniques, and health issues, Littleton, CO, USA, pp 161–182
Yang KX, Kitto ME, Orsini JP, Swami K, Beach SE (2010) Evaluation of sample pretreatment methods for multiwalled and single-walled carbon nanotubes for the determination of metal impurities by ICPMS, ICPOES, and instrument neutron activation analysis. J Anal Atomic Spectrom 25(8):1290–1297
Younger PL, Banwart SA, Hedin RS (2002) Hydrology, pollution, remediation. Kluwer Academic Publ, Dordrecht
Acknowledgements
The authors gratefully acknowledge the support of the Liverpool John Moores University, Faculty of Engineering and Technology PhD Scholarship Programme that allowed this research to be undertaken.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Frau, I., Korostynska, O., Mason, A. et al. Comparison of Electromagnetic Wave Sensors with Optical and Low-frequency Spectroscopy Methods for Real-time Monitoring of Lead Concentrations in Mine Water. Mine Water Environ 37, 617–624 (2018). https://doi.org/10.1007/s10230-018-0511-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10230-018-0511-7