Introduction

In a reservoir, wind-induced currents and the structure of the thermocline mainly control the vertical distribution of heat, dissolved substances, and nutrients in the water column. Understanding lake hydrodynamics is important for management of water resources, and thermal stratification is of great importance for the pattern of mixing in lakes and reservoirs.

Stratification during the summer acts as a barrier restraining mixing of the water column. The warm water in the epilimnion is unable to move through the cold, dense water of the hypolimnion. As a result of incomplete mixing of the water column and lack of light for the photosynthesis at the hypolimnion, the water column can become anoxic.

This study was motivated by the degradation of water quality in the summer because of thermal stratification, as observed in many reservoirs and lakes around the world. Tahtali Lake, providing 40% of its fresh water to Izmir, Turkey, was selected as study site, because the lake experienced dense stratification during the summer months leading to deterioration of water quality.

The objective of this study was to investigate the structure of the thermal stratification, its relationship to wind and flow conditions, and its effect on water-quality parameters including dissolved oxygen and suspended sediment concentrations. Existing studies have primarily focussed on developing water-quality models, in which the physical processes of transport and mixing within the water body have generally been oversimplified, or on extending hydrodynamic models to include water-quality components by combining them with simple input–output models (Hamilton and Schladow 1997). Numerical models developed by Bell et al. (2006), Stefan and Fang (1994), Bonnet et al. (2000) are among the various models developed for simulating temperature and dissolved oxygen in lakes. However most of the studies in the literature lack the extensive field measurements required for investigation of the meteorological factors affecting water-quality variations. Within the scope of this study, monthly measurements were conducted and the impact of these factors on stratification and on water-quality parameters was investigated.

In this study, the factors causing mixing of the water column were investigated by nondimensional analysis (Imberger 1998) which determines the degree of stability and mixing in the lake. The water-quality index (Water-research 2006a) was also used to assess overall water quality in the lake during the winter and summer periods.

Motivated by the water-quality index results, field observations were conducted monthly in the vertical water column where water-quality parameters and temperature profiles were measured. To examine the behaviour of the parameters further, measurements over a longer period (1 month) were made, during which data were recorded internally every half an hour. Results were analyzed by statistical analysis. Simca-P 10.5 software (Umetrics 2003) was used for multivariate analysis of the water-quality parameters.

Study site

The observations were conducted in Tahtali Reservoir, Menderes, Turkey (38°15′N, 27°28′E). Tahtali Dam was projected as a rockfill dam and completed in 1996 to supply fresh water to Izmir, the third largest metropolitan area with a population of over 3 million. The capacity of the dam is 175 million m3 and it generates a total of 5 million m3 water monthly with an average water discharge of 3 m3 s−1. The dam is currently operated by Izmir Water and Sewage Administration (IZSU).

Lake Tahtali has a surface area of 20 km2, a mean depth of 15 m, and a maximum depth of 27 m. The lake is located 60 m above sea level. The major inflows are from the north via Sasal Stream (Murat Stream and Dari Stream) and Tahtali Stream (Fig. 1). Discharge of the other four tributaries is negligible. The only outflow point is at the Southwest location of the lake from the deepest area, corresponding to 27 m. The water is provided as drinking water for city of Izmir after being treated.

Fig. 1
figure 1

Bathymetric map of Lake Tahtali. The darker area represents the deepest region of the lake corresponding to 27 m. The buoy, where stationary measurements were made, is shown by a circle

The site is exposed to the full force of wind blowing mostly from East and also from the North. The average annual wind speed is 3 m s−1. The locale has a Mediterranean climate, with average annual temperatures for the warmest month, July, of 28°C and for the coldest month, January, of 8°C.

Instrumentation

A water-quality meter (WQC) was used to measure turbidity by the scattered light measurement method. Turbidity is measured by reading of the amount of scattered light and is expressed in terms of the optical property causing the light beam passing through the sample of fluid to be scattered and absorbed rather than transmitted. The relationship between suspended solids in the liquid and light intensity due to particle scatter is determined by calibration of the instrument.

Data collection in Lake Tahtali was achieved from a boat stationed at a buoy (depth 19 m), where the WQC-24 water-quality meter designed by TOA-DKK was used for measurements. The instrument is capable of measuring water-quality parameters (pH, conductivity, salinity, dissolved oxygen, turbidity, temperature) and a depth sensor is attached.

Meteorological data were acquired from a weather station designed by TFA (Master Touch) located on the southwest shoreline of Lake Tahtali (Fig. 1). The data collected at this weather station included air pressure, air temperature, humidity, solar radiation, wind speed, wind direction, and rain. Evaporation data were provided by IZSU.

Methodology

The stratification in the lake was assessed by non-dimensional parameter analysis. The Lake number (Imberger 1998), an indicator of the degree of stability and mixing in the lake, was used for this analysis. L N was calculated for Lake Tahtali, using the daily conditions in August 2006, by use of the equation:

$$ L_{{\text{N}}} = {{\left[ {S_{{\text{t}}} {\left( {H - h_{{\text{T}}} } \right)}} \right]}} \mathord{\left/ {\vphantom {{{\left[ {S_{{\text{t}}} {\left( {H - h_{{\text{T}}} } \right)}} \right] }} {{\left\lfloor {u_{*} ^{2} A_{{\text{s}}}^{3/2}{\left( {H - h_{{\text{T}}} } \right)}} \right\rfloor }} {{\left\lfloor {u_{*} ^{2} A_{{\text{s}}} ^{3/2} {\left( {H - h_{v} } \right)}} \right\rfloor }}}} \right. \kern-\nulldelimiterspace} {{\left\lfloor {u_{*} ^{2} A_{{\text{s}}}^{3/2} {\left( {H - h_{v} } \right)}} \right\rfloor }} $$
(1)

where H is the total depth of the lake, h T is the height from the bottom of the lake to the seasonal thermocline, h v is the height to the centre of volume of the lake, A s is the surface area of the lake, g′ is the reduced gravity, Δρ is the density difference between the hypolimnion and the epilimnion, \( \overline{\rho } \) is the average density of the lake water, g is the gravity, A 1 and h 1 are the area and the thickness of the upper layer, A 2 and h 2 are the area and the thickness of the bottom layer, u * is the water shear velocity due to the wind (Eq. 2), ρ a is the density of air, ρ w is the density of water calculated following Rubin and Atkinson (2001) (Eq. 3), U (10) is the wind speed 10 m above the water surface, and S t is stability (Eq. 4).

$$ u_{*} = {\left[ {0.0013{\left( {\frac{{\rho _{{\text{a}}} }} {{\rho _{{\text{w}}} }}} \right)}U^{2}_{{{\left( {10} \right)}}} } \right]}^{1/2}$$
(2)
$$ \rho _{{\text{w}}} = 1,000{\left[ {1 - 0.00663{\left( {T - 4} \right)}^{2} } \right]} $$
(3)
$$ S_{{\text{t}}} = \frac{1} {2}{g}\ifmmode{'}\else$'$\fi{\left[ {{{\left[ {{\left( {A_{1} A_{2} h_{1} h_{2} } \right)}{\left( {h_{1} + h_{2} } \right)}} \right]}} \mathord{\left/ {\vphantom {{{\left[ {{\left( {A_{1} A_{2} h_{1} h_{2} } \right)}{\left( {h_{1} + h_{2} } \right)}} \right]}} {{\left[ {{\left( {A_{1} h_{1} } \right)} + {\left( {A_{2} h_{2} } \right)}} \right]}}}} \right. \kern-\nulldelimiterspace} {{\left[ {{\left( {A_{1} h_{1} } \right)} + {\left( {A_{2} h_{2} } \right)}} \right]}}} \right]} $$
(4)

After solving Eq. 1, L N was calculated for the conditions in August 2006. Because the critical value for stratification was found to be 3, the wind speed corresponding to this value was calculated for Lake Tahtali (3 m s−1). In August, 18% of the time, L N was smaller than the critical value. In October, the percentage of the time that L N was smaller than the critical value increased to 33%.

Water quality in the lake was assessed using a water-quality index—a 100 point scale that summarizes results from a total of nine different measurements (Water-research 2006a). According to this index; the parameters dissolved oxygen (DO), faecal coliforms, pH, biochemical oxygen demand (BOD), temperature, total phosphate, nitrates, turbidity, and total solids are used to assess the overall quality of the lake. Faecal coliform and total phosphate data were not available for Lake Tahtali; the other data were obtained from measurements conducted by IZSU. The weighting factors used in this analysis were obtained from people representing a wide range of positions at local, state, and national levels in the USA (Water-research 2006a). Saturation dissolved oxygen concentration (mg l−1) was calculated following Markofsky and Harleman (1971) as:

$$ {\text{DO}}_{{{\text{sat}}}} = 0.0043T^{2} - 0.36T + 14.48 $$
(5)

The water-quality index of Tahtali Lake was calculated as 79 (Good) for April 2006 and 59 (Medium) for August 2006, as shown in Table 1. Because the results indicated deterioration of water quality for summer period, the factors affecting water quality were further investigated within this study.

Table 1 Parameters used to determine the water-quality index for Tahtali Lake

Data collection and analysis

Field observations were made in Tahtali Lake, where a multiparameter water-quality meter was deployed at monthly intervals to investigate the effects of stratification. The velocity measurements and suspended sediment concentration data were measured simultaneously when the boat was attached to a buoy in the lake. The location of the buoy is shown in the bathymetry map of Tahtali Lake (Fig. 1). Water-quality data were measured at 1-m intervals in the vertical and were recorded at one-minute intervals.

The observed temperature profiles at the buoy are given in Fig. 2a. The depth of the water column where the buoy was located was 18 m. As one can see in the figure, stratification was evident in August where water temperature at the surface reached 28°C and the thermocline started at a depth of 10 m. In October, however, surface temperatures decreased to 21.5°C and the thermocline moved to a depth of 14 m, indicating mixing of most of the water column. In November, the temperature profile was uniform throughout the water column at ∼15°C.

Fig. 2
figure 2

The temperature (a) and dissolved oxygen (b) profiles observed during field measurements conducted once a month at the buoy

The observed dissolved oxygen (DO) profiles are presented in Fig. 2b. Observed DO values dropped well below the standard limit of 5 mg l−1 (Water-research 2006b) at the thermocline, leading to the development of anoxia during the summer period. This can partly be explained by sinking of organic material produced in the epilimnion to the thermocline, where oxidization reduces the DO in the thermocline. As mixing was induced during the fall by the decrease of air temperature, and thus water temperatures at the epilimnion, an increase in DO values at the epilimnion were observed while deepening of the level of maximum DO proceeded until it reached the bottom. In November, the DO profile was uniform throughout the water column at ∼9 mg l−1. The increase in the DO concentration below the thermocline observed in August was attributed to convective circulation introduced by lateral flow from side arms of the lake. In fact, synchronized measurement of velocity profiles using an acoustic Doppler current profiler (ADCP) at the buoy depicted increase of velocities in the transverse direction close to the bed, an indication of this flow from the side arms (Fig. 3). Details of velocity measurements are provided in Çalışkan and Elçi (2007).

Fig. 3
figure 3

Measured velocity profiles at the buoy in August, measured by the acoustic Doppler current profiler (ADCP)

The variation of the turbidity profiles measured by the water-quality meter is presented in Fig. 4a. Turbidity peaks are found mostly in the thermocline region. Turbidity increases are closely related to the location of the maximum density gradient in the vertical, where low turbulence is expected because of stabilization of the water column. A noticeable increase in turbidity toward the bottom of the lake on 17.10.06 was probably because of the effect of the relatively cold sediment-laden water flowing into the lake after a rain event.

Fig. 4
figure 4

The turbidity (a), electrical conductivity (b), and pH (c) profiles observed during field measurements conducted once a month at the buoy

The observed conductivity and pH profiles are presented in Figs. 4b, c. A decrease in pH in the lower layers of the stratified lake was observed due to accumulation of CO2, because no light could penetrate through the thermocline to the hypolimnion during the summer period and plants could not consume CO2 by photosynthesis. Furthermore, CO2, released as a result of decomposition of organic matter in the hypolimnion dissolves in water to form carbonate ions, increasing the ion concentration. This increase in the ion concentration was reflected as an increase of electrical conductivity measured in the hypolimnion during the summer period. In November, the pH and the electrical conductivity profiles were uniform throughout the water column at ∼8 and ∼30 ms m−1, respectively.

Besides the measurements conducted in the lake once a month, the water-quality meter was left at a depth of ∼11 m (thermocline) during August (no mixing), October (partial mixing), December (mixed), and April (partial mixing). The variations of DO data recorded internally every half an hour, with air temperature recorded at the weather station, are given in Figs. 5, 6, and 7 for August, October, and December, respectively.

Fig. 5
figure 5

Variation of DO with air temperature in August 2006. The water-quality meter was at a depth of ∼11 m (thermocline)

Fig. 6
figure 6

Variation of DO with air temperature in October 2006. The water-quality meter was at a depth of ∼11 m

Fig. 7
figure 7

Variation of DO with air temperature in December 2006. The water-quality meter was at a depth of ∼11 m

As can be seen in Fig. 5, an increase was observed in the DO observations, with DO values increasing from 0 to 1.8 mg l−1 (day 21). The air temperature data collected at the weather station for the same measurement period indicated that air temperatures decreased from 40.1 to 35.6°C, with a 4.5° difference between highest daytime temperatures (maximum), and from 25 to 21.9°C, with a 3.1° difference between lowest overnight temperatures (minimum). The air-temperature difference observed during the day was 13.7° whereas this difference was 1.7° for water temperature.

In October (Fig. 6), a similar increase in DO observations occurred, with DO values increasing from 6.6 to 11 mg l−1 (day 10). The data collected at the weather station for the same measurement period indicated that air temperatures decreased from 25.5 to 23°C, with a 2.5° difference between maximum temperatures, and from 18 to 14.8°C, with a 3.2° difference between minimum values. The air-temperature difference observed during the day was 8.1° whereas this difference was 2° for water temperature.

The data observed in December (Fig. 7) showed DO values increased from 9.7 to 10.5 mg l−1 (day 28). The data collected at the weather station for the same measurement period indicated that air temperatures decreased from 12 to 8.4°C, with a 3.6° difference between maximum temperatures, and from 5.7 to 0°C, with a 5.7° difference between minimum values. The air-temperature difference observed during the day was 8.5° whereas this difference was 1° for water temperature.

One day before the increases observed in the values of DO concentration in both August and October, the wind speed values were measured as 4.5 and 5 m s−1 leading to L N of 3. However, because L N was equal to 3 at other times before the increases, L N can not be accepted as a sufficient indicator alone and the direct effect the other parameters including air and water temperatures should be incorporated into equations describing the behaviour of the DO.

Figure 8 shows the variation of turbidity, recorded by the water-quality meter, with the wind speed, measured at the weather station, for August. Since no rain was recorded in August, the local peaks (days 19, 20 and 23) observed in turbidity measurements can be attributed to variation of wind gusts before those days. Waves are formed due to shear stresses induced by wind promoting resuspension in the water column. In October (Fig. 9), turbidity increased from 6 to 14 mg l−1 after the high wind gusts were observed (days 2 and 3) and no rain was recorded before those days either. In December (Fig. 10), as complete mixing of the water column was reached, high turbidity values were observed compared with the other months. Peak turbidity values increased from 26 to 36 mg l−1 (day 25) and can be attributed to the high wind gusts observed one day before and 4 mm of rain measured three days before the peak turbidity was measured.

Fig. 8
figure 8

Variation of recorded turbidity and wind speed in August 2006. The water-quality meter was left at a depth of ∼11 m (thermocline)

Fig. 9
figure 9

Variation of recorded turbidity and wind speed in October 2006. The water-quality meter was left at a depth of ∼11 m

Fig. 10
figure 10

Variation of recorded turbidity and wind speed in December 2006. The water-quality meter was left at a depth of ∼11 m

Statistical analysis

Multivariate analysis was carried out on a data matrix of seven variables (air temperature, wind speed, wind direction, lagged wind speed, humidity, evaporation, and temperature difference). The purpose of this analysis was to determine which of these variables were influential in modelling water-quality parameters such as pH, conductivity, DO, and turbidity. Rainfall data were excluded from the analysis, because it rained only twice during the period of the observations and thus data were insufficient to include in the analysis. Wind-speed data were lagged by 24 h, and 24-h differences in air temperatures were included in the model. Time intervals for lags and differences were decided on the basis of visual interpretations of data time series. Models developed by principal-component analysis (PCA), and partial least-squares (PLS) analysis expressed the correlations between different variables which were used to identify the most influential variables. Simca-P 10.5 software (Umetrics 2003) was applied for PCA and PLS modelling.

PCA shows the correlation structure of data matrix (X) approximated by a matrix product of lower dimension (TP′) plus a matrix of residuals (E):

$$ \rm X = \overline{X} + {T{P}\ifmmode{'}\else$'$\fi } + E $$
(6)

where (T) is a matrix of scores summarizing the X variables and (P) is a matrix of loadings showing the influence of the variables, and (E) is the matrix of residuals showing the deviations between the original and projected values (Umetrics 2003).

Principal-component analysis (PCA), an efficient tool for investigating the interconnection of the datasets, was applied to the water-quality data. In the winter model, water temperature was found to be inversely correlated with pH, DO, turbidity, and conductivity.

Partial least-squares (PLS) analysis extracts the degree of explanation of the dependent Y variables (water-quality parameters) for each independent X variable (air temperature, wind speed, wind direction, lagged wind speed, humidity, and temperature difference) and the degree of correlation between the X variables as follows:

$$ Y = f(X) + \rm E $$
(7)

PLS modelling consists of simultaneous projections of both the X and Y spaces. The structure of the PLS modelling consists of Eqs. 69.

$$ Y = \overline{Y} + {{\rm {{U{C}\ifmmode{'}\else$'$\fi}} }} + F $$
(8)
$$ \rm U = T + H $$
(9)

where, (U) is a matrix of scores summarizing the Y variables and (W) is a matrix of weights expressing the correlation between X and U(Y). (C) is a matrix of weights expressing the correlation between Y and T(X). (F) and (H) are the matrices of residuals. The first component of the PLS model explains more of the variance than the second component, so only coefficients of the first component are given here.

PLS analysis was used to investigate the impact of the different variables on each particular water-quality parameter. The relations were analyzed with the help of the coefficient and variable importance plots. The coefficients used in the PLS model are given in Table 2. Wind direction and evaporation were found as insignificant compared with other relevant variables and are not shown in the table. According to the results from PLS analysis, in winter, air temperature and one-day-lagged wind speed were the most dominant variables affecting observed dissolved oxygen and turbidity values. However, in summer and in fall, humidity and air temperature were the most dominant variables.

Table 2 Coefficients used in the PLS model for Tahtali Lake

Figure 11 depicts the correlation structures between the independent variables (X) and the dependent water-quality parameters (Y). Variables situated along the same directional axis correlate with each other. The weights for the X variables, denoted w, indicate how much they participate in the modelling of Y in a relative sense and the weights of the Y variables, denoted c, indicate which Y variables are modeled. The winter model extracted two significant components from the data set explaining 52% of the variance in the observed water-quality parameters (Fig. 11a). The summer model explained 71% of the variance using two components (Fig. 11b), and the fall model explained 72% of the variance using two components (Fig. 11c). Results indicated that air temperature, lagged wind speed, and humidity are the influential parameters affecting variations in water-quality parameters.

Fig. 11
figure 11

The relationships between the dependent Y and independent X variables as obtained from PLS analysis of the winter (a), summer (b), and fall (c) data. Variables situated closely are positively correlated and when placed at the outer ends are negatively correlated. In the figure, T a denotes the air temperature, dT is daily temperature change, EV is evaporation, EC is conductivity, DO is dissolved oxygen,T w is water temperature, and 24 h lagged wind speed is represented by WS.L48. w on the axis indicates the weights for the X variables in the modelling of Y, and c indicates which Y variables are modelled

Conclusions

It was observed that stratification alters velocity profiles drastically and thus affects water quality in the reservoir. Therefore, the sensitivity of water-quality parameters to wind and stratification was investigated; this is useful for mitigation of pollution problems and for prediction of reservoir water quality and development of maintenance schemes. The water-quality parameters are found to be correlated with temperature profiles in the vertical except at the thermocline. It was observed that the thermocline behaved as a barrier for dissolved oxygen, which dropped well below the standard limit of 5 mg l−1 at the thermocline leading to the development of anoxia. It was concluded that Lake number alone is not a sufficient parameter to assess the behaviour of DO in the water column, and variations in air temperature and humidity must be included in the analysis. Other parameters leading to changes in concentrations of dissolved oxygen and sediment concentration were investigated by statistical analysis of observed data.

Turbidity profiles were highly affected, with stratification where suspended sediment concentrations increased at the thermocline. High wind gusts increased the turbidity in the water column although the affect was temporary. As expected, high turbidity was observed after rain events, because of erosion of the lake banks. Although rainfall data were excluded in the statistical analysis, because of lack of rainfall, inclusion of rainfall data is recommended in the models predicting turbidity.

Multivariate analysis investigated the impact of the different variables including air temperature, wind speed, wind direction, and lagged wind speed on each particular water-quality parameter. The relationships were analyzed with the help of the coefficient and variable importance plots. Wind direction and evaporation were found to have no influence on water-quality parameters. One-day lagged wind speed influenced the parameters more than average wind speed or gust values measured at the site. Fall, summer, and winter models described the correlation structures between independent (meteorological) and dependent (water-quality) parameters. The winter model extracted two significant components from the data set explaining 52% of the variance in the observed water-quality parameters The summer model explained 71% and the fall model explained 72% of the variance using two components.

Results of the statistical analysis showed that air temperature, lagged wind speed, and humidity are the influential parameters affecting variations in water-quality parameters. Therefore in such analysis the non-dimensional parameters water temperature and wind alone do not suffice, and variations in water quality structure should be evaluated by new approaches considering other meteorological factors.