Abstract
The huge amount of medical waste (MW) has caused a tough challenge to environmental protection in China because of its serious infectious potential. At present, incineration is the most common technology for MW disposal. Unfortunately, the medical waste incinerator (MWI) is considered one of the major sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study was conducted to investigate the generation and the components of MW; the fingerprint of PCDD/Fs in MWI; and PCDD/F, polychlorinated biphenyl (PCB) and hexachlorobenzene concentrations in residue ash. The estimated annual production of MW was estimated to be 0.97 million tons in China in 2008; in addition, plastic and rubber accounted for 24.5% of MW contents. PCDD/F emissions from MWI could be divided into two main groups according their fingerprints, and the ratio of PCDFs/PCDDs was mostly over 1.5, with a mean value of 3.43. The toxic equivalent of PCDD/Fs was over 30 times that of the value of PCBs in the residue ash, and PCDD/F contents in fly ash accounted for approximately 67% of the total output of PCDD/Fs, which was in line with the UNEP default emission factors for MWI (class 3, 63.7%).
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Medical wastes (MW) are the hazardous refuse generated by hospitals, clinics and other related health-care institutions, and typically consist of sharp objects, chemicals and blood components. They are characterized by being toxic and infectious, and have the potential to cause health risks and environmental pollution with improper treatment and management. With the rising awareness of the importance of environmental protection, more public and scientific communities are concerned about MW disposal and proper treatment [1–3]. In many developed countries, specific rules and regulations have been implemented for MW management, and are performed highly effectively. With the fast economic development in China, many social problems and difficulties have emerged, such as environmental pollution. China has historically paid little attention to the strict management of MW. In the last decade, laws, regulations and rules, as well as standards, were gradually established and implemented at all stages of MW management, including separation, collection, packaging, storage, transport, treatment and disposal [4]; however, the actual performance of these tasks is still not perfect.
Off-site central incineration has been widely demonstrated to be a fast and commercially available technology for disposing of MW, as direct landfill has been forbidden since 2002 in China [5]. According to the National Hazardous Waste and Medical Waste Disposal Facility Construction Plan, 331 modern, high-standard, centralized incinerators were to be built by the end of 2006; in addition, on-site incineration was to be gradually abandoned [6]. However, incineration is also a controversial issue because of the potential for secondary pollution, such as emissions of HCl, NOx, heavy metals and persistent organic pollutants (POPs) [7–10]. In 2004 in China, 1.18 kg I-TEQ of PCDD/Fs was reported to have been released from medical waste incineration [11]. Therefore, it is quite essential and inevitable to understand the present situation of MW generation and PCDD/F emissions in thermal processes in China.
Generation and components of MW
With the stable economic development of over 7% of the GDP growth rate, the demand for and consumption of health care has also been rising significantly each year. Increasing numbers of hospitals and clinics are being built, and citizens frequently visit the health institutions. The Ministry of Health has recorded the statistical data of health consumption and construction [12]. Table 1 shows the beds in hospitals for inpatients and the visiting times of outpatients. Both beds and outpatient visiting times have markedly increased in the last decade. Meanwhile, the production of MW has also rapidly increased.
Both outpatients and inpatients generate MW during health institution visits. The waste generation rates are quite different. Based on the reported data (Table 2) [3, 13–15], the rate of inpatients in China is on average 0.58 kg/bed × day, and approximately 20–30 outpatient visits produce 1.0 kg of waste [16]. Therefore, the annual generation of MW can be calculated, as shown in Figs. 1 and 2. The yield of MW was found to increase quickly, and 0.97 million tons of MW was generated in China in 2008. Also in another report the amount of MW produced in 2002 was reported to be 0.65 million tons [17].
Many factors influence the composition of MW, including function, scale, season and management. Therefore, it is very difficult to exactly classify the components of MW. We reviewed the surveys of MW composition by different researchers in different cities (Table 3). Regarding the average composition of MW shown in Table 3, the major components are fibrous material, plastic and rubber, which have a high caloric value (10,000–16,000 kj/kg) and chlorine content (4.5–7.5%) compared to municipal solid waste [19, 20].
PCDD/F emissions from MWI
Materials and methods
MWI is among the major sources of PCDD/Fs in the environment [24]. We conducted the determination of PCDD/Fs in stack gas and PCDD/Fs, PCBs and HxCBz in residue ash collected from several waste incinerators. Brief information about the MWI as well as the sample numbers is shown in Table 4. Open burning of MW is defined as MWI8. Hazardous waste was co-combusted with medical waste in HWI9.
The stack gas samplings were carried out according to USEPA method 23 by isostack sampler (M5, KNJ Engineering, South Korea). The particle phase was collected using a glass fiber filter, and the gas phase was collected using XAD-2 resin. The fly ash was collected in the exit of the bag house and bottom ash in the exit of the slag remover. The preparation (extraction and purification) of samples and the instrument analysis of PCDD/Fs and PCBs were performed as in our previous studies [10, 25]. The analysis of PCBs and PCDD/Fs was done by HRGC/HRMS on a 6890 Series gas chromatograph (Agilent, USA) and coupled to a JMS-800D mass spectrometer (JEOL, Japan). The HxBz analysis was conducted in the GC-ECD (Agilent 6890N GC). The pretreatment of HxCBz analysis was according to the state method of HJ/T 74-2001 and GB 7492-87 in China, consisting of extraction and a clean-up procedure (H2SO4 treatment, multi-layer silica gel column and Florisil).
PCDD/F homologue pattern in the samples collected from MWI
Hongcai Gao [9] measured the stack gas emissions of PCDD/Fs from MWI in China. The concentration ranged from 0.08 to 31.6 ng I-TEQ Nm−3, with a median value of 0.41 ng I-TEQ Nm−3 and an average concentration of 4.22 ng I-TEQ Nm−3. In our research, the level of PCDD/F emissions ranged from 0.32 to 16.43 ng I-TEQ Nm−3, with a median of 4.69 ng I-TEQ Nm−3 and a mean of 5.85 ng I-TEQ Nm−3. According to our research, much work and many improvements need to be carried out in order to meet the present emission limits (0.5 ng I-TEQ Nm−3) and the more stringent regulations coming in the future (0.1 ng I-TEQ Nm−3). PCDD/F homologue patterns as the fingerprint of PCDD/Fs are the characteristic emissions from different sources. The degree of chlorination of PCDD/Fs and the ratio of PCDFs to PCDDs are shown in Table 5. The ratio of PCDFs to PCDDs was over 1.5 in most of the samples, and 3.43 on average. That the ratio of PCDFs/PCDDs is higher than 1.0 is a typical combustion fingerprint of PCDD/Fs. Also, de novo synthesis was indicated to be the predominant mechanism of PCDD/F formation [26]. The degree of chlorination of PCDD/Fs was also calculated and ranged from 4.90 to 6.11, being 5.50 on average. Compared to the PCDD/F emissions from municipal solid waste incinerators (6.68, an average of 12 units) [27], the degree of chlorination was not directly increased by the higher content of chlorine in waste.
Hierarchical cluster analysis (HCA) was used to evaluate the similarities and differences of PCDD/F homologue patterns in the samples collected from MWI. According to the analysis results, the samples were assembled into two main groups (group I and II). The PCDD/F fingerprint of these two main groups is depicted in Fig. 3. In group I, percentages of TeCDFs to HxCDFs were similar, and the portion of PCDFs gradually decreased with the increasing degree of chlorination in group II.
POP concentrations in residue ash
In China, there are no precise regulations for the limits of PCDD/Fs in ash. Also the environmental protection agencies do not monitor the PCDD/F concentrations in residue ash. Actually, a quantity of organic pollutants existed in ash. Therefore, the measurement of POPs in residue ash was conducted in this study, and the results are shown in Tables 6 and 7. The concentration of PCDD/Fs ranged from 0.16 to 7.31 ng WHO-TEQ g−1 in fly ash, 3.95 × 10−3 to 0.17 ng WHO-TEQ g−1 in bottom ash of incinerators and 4.04 ng WHO-TEQ g−1 in ash from open burning, respectively. In addition, the concentration of PCBs ranged from 12.1 × 10−3 to 0.39 ng WHO-TEQ g−1 in fly ash, 0.08 × 10−3–3.00 × 10−3 in bottom ash of incinerators and 0.94 ng WHO-TEQ g−1 in ash from open burning. The TEQ of PCBs was so tiny in fly ash that it was only approximately 3% compared to the value of PCDD/Fs. Also, there was a quantity of HxCBz in fly ash and bottom ash. More attention needs to be paid to fly ash treatment to prevent secondary pollution.
Distribution of PCDD/Fs output in MWI
Pollutants from incinerators can be emitted into the environment via several routes. The three major routes include fly ash, stack gas and bottom ash. In order to understand the portion of pollutant emissions in different substances, an assessment was conducted. The analyzed results are presented in Table 8. The results demonstrated that fly ash dominated in the output of dioxin, accounting for 67% of the total dioxin output on average. The distribution of PCDD/Fs in different substances was consistent with the UNEP default emission factors for MWI (class 3). On the other hand, the distribution of PCDD/Fs in MWI was similar to the results for MSWI [28]. Consequently, disposing of residue ash using an appropriate method is also essential.
Conclusion
In this study, the annual generation of MW in China was estimated. The amount of MW observed was huge, and it is increasing significantly. The characteristic PCDD/F emissions from MWI were investigated, and the organic contaminants in residue ash were also measured. It is essential to pay more attention to the disposal of fly ash and to implement much stricter regulations to prevent secondary pollution.
References
Duan H, Huang Q, Wang Q, Zhou B, Li J (2008) Hazardous waste generation and management in China: a review. J Hazard Mater 158:221–227
Liu YS, Ma LL, Liu YS, Kong GX (2006) Investigation of novel incineration technology for hospital waste. Environ Sci Technol 40:6411–6417
Zhang Y, Xiao G, Wang G, Zhou T, Jiang D (2009) Medical waste management in China: a case study of Nanjing. Waste Manage 29:1376–1382
Chen Y, Li P, Carlo L, Sun YZ, Xu DD, Feng Q, Fu SS (2009) Sustainable management measures for healthcare waste in China. Waste Manage 29:1999–2004
Ministry of Environmental Protection of China (2002) Standard for pollution control on the security landfill site for hazardous wastes (in Chinese). No. GB18598-2001
National Development and Reform Commission of China (2003) Hazardous waste and medical waste treatment facility construction program (in Chinese). http://www.ndrc.gov.cn/hjbh/huanjing/t20050711_45850.htm
Zhao L, Zhang FS, Wang K, Zhu J (2009) Chemical properties of heavy metals in typical hospital waste incinerator ashes in China. Waste Manage 29:1114–1121
Sabiha J, Tufail M, Khalid S (2008) Heavy metal pollution from medical waste incineration at Islamabad and Rawalpindi, Pakistan. Microchem J 90:77–81
Gao H, Ni Y, Zhang H, Zhao L, Zhang N, Zhang XP, Zhang Q, Chen JP (2009) Stack gas emissions of PCDD/Fs from hospital waste incinerators in China. Chemosphere 77:634–639
Chen T, Li X, Yan J, Jin Y (2009) Polychlorinated biphenyls emission from a medical waste incinerator in China. J Hazard Mater 172:1339–1343
PR China National Implementation Plan Committee (2007) PR China National Implementation Plan for the stockholm convention on persistent organic pollutants (in Chinese). http://www.pops.int
Ministry of health of The People’s Public of China (2009) Chinese health annual statistics (In Chinese). http://www.mohgovcn/publicfiles/business/htmlfiles/zwgkzt/ptjnj/200908/42635htm2009
Ruzi K (2009) Research of medical waste output in Urumqi. J Xinjiang Univ 26:97–102 Natural Science Edition
Yan G, Yuan XZ, Zeng G (2002) Investigation on management of medical wastes in Changsha. J Environ Health 19:393–394 (in Chinese)
Yu CH, Tan XD (2002) Investigation on the disposal of medical garbage in Wuhan. Chin Hosp Manag 22:19–22 (in Chinese)
Fang Y (2001) Make the medical waste innocently by management. Fujian Environ 18:33–34 (in Chinese)
Zhang H, Wang L (2005) Discussion on medical waste treatment methods. Environ Sanit Eng 13(6):19–21 (in Chinese)
Zhou LX, Lu Y (2003) Existing condition investigation and treatment policy of solid waste in Hangzhou hospital. Jiangsu Environ Sci 16:32–35 (in Chinese)
Bie R, Li S, Wang H (2007) Characterization of PCDD/Fs and heavy metals from MSW incineration plant in Harbin. Waste Manage 27:1860–1869
Xiao ZW (2010) Basic study on the physical-chemical and pyrolysis-incineration characteristic of typical components in medical wastes. Zhejiang University (Master thesis) (in Chinese)
Xu Q (2000) Status and countermeasures analysis of medical waste. Sci Environ Protect 26:20–23 (in Chinese)
Zhou HD, Zhou ZJ (2008) Survey on management of medical waste in a district of Shanghai. Chin Disinfect Sci 25:638–640 (in Chinese)
Gao Y, Pan S, Qu Y, Ai F (2003) Measure and present status of medical refuse in Zhengzhou city. Eng Environ Sanit 12:77–80 (in Chinese)
UNEP (1999) Dioxin and furan inventories, national and regional emissions of PCDD/F. In: UNEP chemicals. Geneva, Switzerland
Lu SY, Yan JH, Jiang XG, Ma ZY, Li XD, Chi Y, Ni MJ, Cen KF (2008) Experimental study on dioxin emission and reduction in a multi-stage gasification and incineration facility for medical waste. In: 27th annual international conference on thermal treatment technologies, vol 1. pp 172–180
Huang H, Buekens A (1995) On the mechanisms of dioxin formation in combustion processes. Chemosphere 31:4099–4117
Everaert K, Baeyens J (2002) The formation and emission of dioxins in large scale thermal processes. Chemosphere 46:439–448
Johnke B, Stelzner E (1992) Results of the German dioxin measurement programme at MSW incinerators. Waste Manage Res 10:345–355
Acknowledgments
This study was financially supported by the Major State Basic Research Development Program of China (973 Program) (no. 2011CB201500) and a Scholarship Award for Excellent Doctoral Students granted by the Ministry of Education. Grateful appreciation is extended to Xiao-yuan Dai, engineer, and to Prof. Xu-guang Jiang for their help with flue gas sampling.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yan, M., Li, X.D., Lu, S.Y. et al. Persistent organic pollutant emissions from medical waste incinerators in China. J Mater Cycles Waste Manag 13, 213–218 (2011). https://doi.org/10.1007/s10163-011-0020-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10163-011-0020-2