Introduction

As the result of early detection of gastric cancer and technological advances, minimally invasive surgery (MIS) has become the main axis of treatment. In particular, laparoscopic gastrectomy for EGC has been widely accepted as an alternative to open gastrectomy in Korea and Japan [1, 2]. Further, new emerging techniques have been developed to reduce the invasiveness of laparoscopic surgery, such as the natural orifice transluminal endoscopic surgery (NOTES) and single-incision laparoscopic surgery (SILS). Although NOTES is still being studied because of the limitations of current instruments, SILS has been frequently applied in various clinical settings, such as cholecystectomy, appendectomy, colectomy, and sleeve gastrectomy for obesity [3, 4]. However, there have been only three reports about single-incision laparoscopic distal gastrectomy (SIDG) for gastric cancers [57]. Herein, we report a technical note of the first successful single-incision laparoscopic total gastrectomy (SITG) with D1+beta lymph node dissection (LND) for a patient with early proximal gastric cancer.

Case 1

A 50-year-old man with a body mass index of 19.5 kg/m2 was diagnosed with a moderately differentiated early gastric adenocarcinoma by endoscopy as per national screening guidelines. Endoscopic ultrasonography indicated that the tumor invaded the submucosal layer of the high body of the posterior wall of the stomach. Computed tomography (CT) scan revealed that there was no regional lymph node (LN) enlargement or distant metastasis (cT1bN0M0). Informed consent for a single-incision laparoscopic total gastrectomy was obtained.

Operative technique

Single-incision laparoscopic total gastrectomy with D1+beta LN dissection

The patient was placed in a lithotomy position with reverse Trendelenburg. The operator and a scopist were positioned between the patient’s legs. A longitudinal 2.5-cm-long trans-umbilical skin incision was made. A commercial four-hole single port (Glove port; Nelis, Bucheon-si, Gyeonggi-do, Korea) was then placed in the umbilical incision, and the abdominal cavity was insufflated with carbon dioxide at a pressure of 13 mmHg (Fig. 1). There was no additional assistant trocar. A 10-mm flexible high-definition scope (Endoeye flexible HD camera system; Olympus Medical Systems, Tokyo, Japan) and a Harmonic Scalpel (Ethicon Endo-Surgery, Cincinnati, OH, USA) were used to visualize every corner of the operative field and facilitate dissection. We used the conventional laparoscopic grasper when operating in the greater curvature side and the prototype curved instruments (Olympus Medical Systems) when operating in the lesser curvature side, including the suprapancreatic LND and division of the esophagus. Modified combined suture retraction of the falciform ligament and the left lobe of the liver was performed using 2-0 prolene on a straight needle and 5-mm hemoclips [8]. Partial omentectomy was initiated distally approximately 3–4 cm away from the gastroepiploic arcade, which included the LN 4d. To prevent omental infarction, the left gastroepiploic vessels were ligated distal to the omental branch. Then, the omentum was dissected and taken down from the mesocolon to the head of the pancreas and duodenum. The right gastroepiploic arcade was approached in a retrograde fashion. We first dissected the space between the duodenum and the basin including the right gastroepiploic vessels and LN station 6 and then detached these from the duodenum and distal stomach. Thus, we could easily dissect and divide the right gastroepiploic area without any significant bleeding. After dissecting LN 6, the right gastric artery and the proper hepatic artery were adequately exposed to dissect LNs 5 and 12a, and the operator exchanged the grasper for the prototype curved instruments. The right gastric artery was then divided at its origin. The duodenum was divided 2 cm distal to the pylorus using a laparoscopic linear stapler (Echelon 60 mm-3.5 and 4.5; Ethicon). LNs 8a and 9, located on the right side of the left gastric artery, were dissected along each artery. The left gastric vein and artery were exposed, individually clipped, and divided to allow dissection of LN 11p. LNs 1 and 2, including the vagus nerve, were dissected and the esophagus was then transected using the stapler. The dissection subsequently proceeded along the LN stations 11p and 11d up to the splenic hilum. The dissection was carried out by the “downstream method” for LNs 2 and 4sa (Fig. 2). The specimen was removed in a plastic bag from the single umbilical incision without any extension.

Fig. 1
figure 1

Position and single-port placement

Fig. 2
figure 2

Lymph node dissection in case 1: a LN #6; b LN #7, 8a, 12a, 7; c 7, 9, 11p; d LN #10, 11d)

Reconstruction

For the intracorporeal anastomosis, we used the modified semi-loop reconstruction for SITG [9]. The jejunal loop was transected approximately 20 cm distal to the ligament of Treitz, using the laparoscopic linear stapler without any division of the mesentery. After a small hole was made at the end of the Roux-en-Y limb on the antimesenteric side and on the left side of the esophageal stump, one stay sutures were placed at the esophageal stump to maintain traction through the single port and another stay sutures were placed at the small hole to facilitate insertion of the stapler. Through the blue channel of the single port, the stapler was inserted. The stapler side was inserted into the small hole of the jejunum while the anvil side was inserted into the small hole of esophageal stump using traction from the stay sutures. After firing the stapler, we carefully checked the lumen to identify any false lumen formation and luminal bleeding. The common entry was simply closed using the stapler with some staying suture, incorporating both the esophageal and jejunal stumps (Fig. 3). Side-to-side jejunostomy was then performed using the linear stapler.

Fig. 3
figure 3

Modified semi-loop esophagojejunostomy in case 1: esophagus transection (a), esophagojejunostomy (b), common entry hole closure by a linear stapler (c), complete view of modified semi-loop esophagojejunostomy (d)

Postoperative outcomes

The total operative time was 175 min. Estimated blood loss was 50 ml. The patient was started on clear fluids on postoperative day 3 and tolerated a soft bland diet on postoperative day 4. Routine patient-controlled analgesia was administered for postoperative pain control, with good effect. The patient was discharged in stable condition without any complications or complaints on postoperative day 6. Results of final pathological analysis revealed no LN metastasis among 56 examined nodes (pT1bN0). The proximal and distal resection margin was 2.1 and 9.8 cm, respectively.

Case 2

The other case was a 46-year-old man diagnosed as having a poorly cohesive gastric carcinoma. Endoscopic ultrasonography and computed tomography revealed the preoperative tumor stage to be cT1bN0M0. He had no severe comorbidity. His body mass index was 18.4 kg/m2. He also underwent SITG with D1+beta LN dissection in the same manner as already described (Fig. 4). The operation time was 205 min, and the estimated amount of blood loss was 60 ml. He started sips of water on the postoperative 3rd day and ate a semibland diet on the postoperative 5th day. He was discharged with no complication and complaints on the postoperative 6th day. The final pathology report revealed that the tumor diameter was 7.2 cm and had invaded the muscularis propria; there were two metastases among 97 LNs dissected (pT2N1). The proximal and distal resection margins were 2 and 11.7 cm, respectively.

Fig. 4
figure 4

Lymph node dissection and esophagojejunostomy in case 2: a LN #6; b suprapancreatic LN area, 8a, 9, 7, 11p; c esophagojejunostomy by a linear stapler; d complete view of modified semi-loop esophagojejunostomy

Discussion

Single-incision laparoscopic surgery was introduced to reduce the minimal invasiveness of laparoscopy to the least invasiveness possible and to achieve excellent cosmetic results. SILS has been applied in various operations, with predominantly benign indications.

SILS is rarely applied for gastric cancer surgery. To the best of our knowledge, there have been only three reports describing this procedure for patients with EGC [57]. Furthermore, all these reports involve SIDG with one or two additional assistant ports.

This is the first case report describing successful single-incision laparoscopic total gastrectomy for early gastric cancer and also the first “pure” SITG without any additional assistant port. In our institution, we conducted an animal study in porcine models before the clinical application of SILS for EGC. We found that D1+beta LND could be performed during SIDG in this animal model [10].

After this animal study, we performed SIDG in 11 EGC patients with the approval of our institutional review board. We reported the first two cases as case reports [6]. Based on these experiences, we prepared to perform pure SITG. The indication of SITG and conventional laparoscopic total gastrectomy (LTG) in our institution was clinical stage I (cT1-T2N0). The initial decision to perform SITG or LTG was mainly determined by the patient’s body mass index, which was between 18 and 21 kg/m2.

For pure SITG, the single-port device is very important for simple and less stressful surgery. The Glove port (Nelis, Buchen, Gyeonggi, Korea) is very effective, with the angle easily adjustable and no air leakage. Each valve can use 2- to 12-mm instruments. In addition, because the port is transparent, instruments can be inserted under direct visualization.

However, it can be difficult to maintain an optimal view in SITG, because of repeated clashes of the camera with the instruments. This technical challenge can be overcome with a flexible HD camera and an experienced camera operator. Further, a curved grasper can improve surgical performance, with less interference, thereby facilitating SILS with reduced time required and improved dexterity. In the future, a 5-mm flexible HD scope may help resolve the clashing of instruments, as more space would be available to move the instruments.

Compared with other laparoscopic approaches, the postoperative cosmetic result from this operation was excellent (Fig. 5), and the incisional pain was minimal on postoperative day 1. The total operative time was similar to that of conventional laparoscopic total gastrectomy. Therefore, this technical report demonstrated the technical possibility of pure SITG and modified semi-loop esophagojejunostomy. Further experience and research are required to confirm the safety and feasibility of SITG.

Fig. 5
figure 5

Single-incision wound after the operation