Abstract
Various authors have reported more effective fluoridation from the use of lasers combined with topical fluoride than from conventional topical fluoridation. Besides the beneficial effect of lasers in reducing the acid solubility of an enamel surface, they can also increase the uptake of fluoride. The study objectives were to compare the action of CO2 and GaAlAs diode lasers on dental enamel and their effects on pulp temperature and enamel fluoride uptake. Different groups of selected enamel surfaces were treated with amine fluoride and irradiated with CO2 laser at an energy power of 1 or 2 W or with diode laser at 5 or 7 W for 15 s each and compared to enamel surfaces without treatment or topical fluoridated. Samples were examined by means of environmental scanning electron microscopy (ESEM). Surfaces of all enamel samples were then acid-etched, measuring the amount of fluoride deposited on the enamel by using a selective ion electrode. Other enamel surfaces selected under the same conditions were irradiated as described above, measuring the increase in pulp temperature with a thermocouple wire. Fluorination with CO2 laser at 1 W and diode laser at 7 W produced a significantly greater fluoride uptake on enamel (89 ± 18 mg/l) and (77 ± 17 mg/l) versus topical fluoridation alone (58 ± 7 mg/l) and no treatment (20 ± 1 mg/l). Diode laser at 5 W produced a lesser alteration of the enamel surface compared to CO2 laser at 1 W, but greater pulp safety was provided by CO2 laser (ΔT° 1.60° ± 0.5) than by diode laser (ΔT° 3.16° ± 0.6). Diode laser at 7 W and CO2 laser at 2 W both caused alterations on enamel surfaces, but great pulp safety was again obtained with CO2 (ΔT° 4.44° ± 0.60) than with diode (ΔT° 5.25° ± 0.55). Our study demonstrates that CO2 and diode laser irradiation of the enamel surface can both increase fluoride uptake; however, laser energy parameters must be carefully controlled in order to limit increases in pulpal temperature and alterations to the enamel surface.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
The inhibition rather than mere treatment of dental caries is an important goal of modern dentistry. The mainstay of action against its development is fluoride [1], applied to dental tissue as pastes, mouthwashes, and pit-and-fissure sealants, among others. The laser now offers dentists a new procedure against the formation of dental caries. Various investigations over the past few years have reported the beneficial effects of laser-produced infrared radiation on enamel, either used alone [2–4] or in combination with fluoride [5–7], increasing its resistance to acids or favoring fluoride uptake, making it more resistant to caries.
Studies on the use of carbon dioxide (CO2) lasers with wavelengths (λ) of 9–11 µm reported structural and ultrastructural changes on the enamel surface, including decomposition of organic matrix, carbonate loss, and recrystallization of hydroxyapatite in less acid-soluble phases [8–10]. In vitro studies have shown the effectiveness of this laser in combination with fluoride to increase the enamel fluoride uptake and reduce its acid solubility [11, 12]. However, CO2 laser can produce undesirable alterations to the enamel surface, including melted areas, fracture lines, and craters [13], and it can even thermally damage dentin or pulp [14].
Only a few studies have addressed the effect on dental enamel of diode laser with a λ of 809–960 nm. A low percentage of this λ is absorbed by hydroxyapatite, and the rest is reflected or transmitted in the form of heat on the surface of the enamel and adjacent structures [15]. However, as with the CO2 laser, this increase in enamel temperature also produces structural and ultrastructural changes that reduce the acid dissolution of the enamel. These include the decomposition of organic matrix, loss of water and carbonates, and formation of acid-insoluble hydroxyapatite phases, such as calcium pyrophosphate or calcium metaphosphate, found in enamel treated with different lasers or heated at 200–400°C [16–18]. Our group previously reported that diode laser in combination with sodium fluoride (NaF) was effective in increasing fluoride uptake by enamel [19]. Other researchers demonstrated a significant decrease in enamel acid solubility [20] and the inhibition of carious lesions in in vitro studies [21]. The diode laser was not designed with this purpose in mind but is much more affordable and easier to use in routine dental practice.
The objective of this study was to compare the effectiveness of CO2 laser versus diode laser, examining their effects on fluoride uptake and on dental enamel and pulp.
Materials and methods
Dental material
This study used third molars that required extraction at the School of Dentistry of the University of Granada (Granada, Spain) from patients not subjected to water fluoridation programs. All patients signed informed consent to participate in this study, which was approved by the ethical committee of the university.
For the first experiment, 45 healthy third molars with no visible defects on enamel surface were selected. Teeth were stored in bidistilled water with 0.02% thymol at 4°C to prevent changes in the optical or mineral properties of the enamel or dentin [22]. The root of each molar was sectioned and the crown was divided longitudinally into two halves, obtaining 90 study specimens. A 4-mm2 enamel window was marked on the surface to be treated, coating the rest of the enamel with an acid-resistant varnish.
Laser treatment
The following lasers were used in the experiments.
-
Gallium aluminum arsenide (GaAlAs) diode laser (Laser Smile, Biolase, San Clemente, CA, USA) at 809 nm λ, beam diameter of 0.6 mm and pulse duration of 30 ms. Two settings were used, designated settings a and b (see Table 1)
-
CO2 laser (Lasersat 15tm, Satelec, Merignac, France) at 10.6 µm λ, beam diameter of 0.6 mm, and pulse duration of 15 ms. Two settings were used, designated c and d (Table 1).
Study method
Selected molars were randomly assigned to one of the following six groups (n = 15): Group 1, enamel window treated for 15 s with 0.1 mg amine fluoride (AmF) (ELMEX Fluid, GABA International AG, Münchenstein, Switzerland); Group 2, enamel window treated for 15 s with 0.1 mg AmF plus application of diode laser at setting (a). Group 3, enamel window treated as above plus diode laser at setting (b); Group 4, enamel window treated as above plus application of CO2 laser at setting (c); Group 5, enamel window treated as above plus CO2 laser at setting (d); Group 6; control group, enamel surface window with no fluoridation treatment.
The enamel window was always exposed to the laser by the same operator in the same manner, at an approximate irradiation distance of 5 mm and in scanning mode, moving the hand-piece longitudinally and uniformly over the entire surface. The aim was to simulate an in vivo experiment, in which the irradiation distance cannot always be precisely maintained. After each treatment, specimens were cleaned for 2 min under distilled water, using an electric toothbrush with standard head (ORAL-B Vitality; Braun, Hesse, Germany).
Environmental scanning electron microscopy (ESEM)
After the treatments, samples were studied with ESEM to detect possible surface defects or alterations, with a minimum of five observations for each treated area. Magnifications ranged from 1000x to 4000x, using a Quanta 400 microscope (Philips, Eindhoven, The Netherlands) equipped with a secondary electron gas detector under operating conditions of 20 kV and 2–3 Torr.
Chemical analysis of fluoride ions
The amount of fluoride ion (F−) on the treated enamel surface was measured with a selective ion electrode (ISE25F, Crison SA, Barcelona, Spain), which is an accurate method to measure small concentrations of fluoride >10 mg/l [23]. The surface was etched with 10 µl of 2 M HCl for 5 s to dissolve the outer enamel surface. The acid with the dissolved enamel elements was gathered on blotting paper disks and transferred to a 2-ml TISAB III solution for F− measurement.
The potential difference obtained in each sample was compared to a reference curve to quantify the fluoride on each treated surface. The reference curve was prepared under the same environmental conditions (21–23°C) as the experiments and with known fluoride concentrations.
Measurement of intrapulpal temperature
This experiment used 20 third molars obtained from patients treated in our university clinic, extracted and stored in the same manner as the samples for fluoride ion quantification and microscopic analysis (see above). Four groups of 5 molars each were randomly formed (A, B, C, D). The pulp was removed from all molars by apico-coronal endodontic preparation, using conventional 25-mm-long k files (DENTSPLY, Maillefer, Tulsa, Ok, USA) and irrigation with 5.25% sodium hypochlorite. A small apical portion of each root was removed so that the apical foramen was typically 2–3 mm wide in diameter in order to facilitate subsequent instrumentation of the pulp chamber. The endodontic preparation sequence was from ISO file #8 to #60. A 4-mm2 window was drawn on the free vestibular or lingual surface as the study area but there was no need to cover any part of tooth with varnish.
In this experiment, we used the same laser settings as in the fluoride ion test, i.e., laser setting a) for group A, b) for B, c) for C and d) for D. The enamel window was exposed to the laser in the same manner as in the ion test (irradiation distance of 5 mm and performed in scanning mode, moving the hand-piece longitudinally and uniformly over the entire surface for 15 s).
Thermal changes during laser irradiation were monitored by using a 0.5-mm k-type thermocouple probe (Omega Engineering Ltd, Manchester, UK) connected to a digital thermometer (Omega Engineering Ltd, Manchester, UK). Adhesive was used to attach the teeth to millimetric glass microscope slides, with the root axis parallel to the slide surface. The temperature-sensitive tip of the probe was positioned at the center of the study area, confirming the localization with radiography. Cement sealing was used to secure the thermocouple in the root opening (Cavit, ESPE, Seefield, Germany). Each molar was filled with physiological saline using a syringe, and the slides with the attached teeth and probe were immersed in a physiological saline thermostatic bath (Microterm, J.P. Selecta SA, Barcelona, Spain) at a constant temperature of 37°C, leaving exposed only the surface to be treated. All experimental designs are depicted in Fig. 1.
Before each measurement, and with the thermocouple placed inside the pulp chamber and connected to a thermometer, we verified that the baseline temperature was 37°C in order to simulate the real thermal diffusion and conductivity conditions of a molar in the oral cavity.
Each group (A, B, C, and D) comprised five molars and five temperature measurements were repeated for each molar, obtaining a total of 25 maximum temperature measurements per group.
Statistical analysis
Means, standard deviations, and ranges were calculated for the study groups. One-way analysis of variance was used to compare means among treatment groups. When the result was significant, paired comparisons were performed between treatment groups using the Bonferroni correction. Treatment groups were also compared with the control group by means of the Dunnett correction. When variances differed among groups, neperian logarithmic transformation was performed. p < 0.05 was considered significant. SPSS for Windows version 15.0 was used for the data analyses.
Results
Analysis of dental surface by ESEM
Figures 2, 3, 4, 5, 6, 7, 8, 9, 10 show the results of the ESEM observations of the surfaces of untreated control molars and of molars treated with diode or CO2 laser under the different conditions tested. Figure 2 shows normal untreated enamel surface (control). Figure 3 depicts the surface treated with AmF 15 s without laser radiation, showing a surface with an apparently normal structure and morphology similar to untreated enamel. Figures 4 and 5 show surfaces treated with 5-W diode laser in the presence of AmF; the enamel appears normal, although there is a small globular agglomerate in the center of the image that is morphologically similar to an agglomerate of calcium fluoride (CaF2). Figure 6 depicts the surface treated with 7-W diode laser; the enamel appears thermally altered, and a slight roughness and some craters are observed at the center of the image, compatible with heat fusion of the surface. Frequent globular precipitates appear on the treated surface, to a greater extent than in specimens treated with 5-W diode laser. Surface exfoliation phenomena can also be seen, as depicted in Fig. 7. Figure 8 shows surfaces treated with 1-W CO2 laser in the presence of AmF. Most of the surface is altered, although without cracks or craters. The globular agglomerates (CaF2) produced by diode laser are not observed. Figure 9 depicts a 2-W CO2 laser-treated surface, evidencing wider thermal alteration and a localized fracture line close to the melted area; craters or exfoliation areas can also be seen with the same treatment in Fig. 10.
Chemical analysis of fluoride ions
Figure 11 depicts the concentrations of fluoride ion obtained in the different treatments, expressed as maximum, minimum, and mean values with standard deviations. We discarded samples treated with 2-W CO2 laser at 30 Hz and 15 s of exposure (setting d), due to the presence of numerous defects in the enamel structure under these conditions.
The global ANOVA test rendered significant results (Fexp = 81.9 (5;84) d.f. p < 0.001), therefore paired comparisons (Bonferroni method) and comparisons with the control group (Dunnett method) were performed. The lower part of Fig. 11 depicts the results obtained: lines that join two or more groups indicate absence of significant differences (p > 0.05). As can be seen, the mean F− concentration was significantly lower in the control group than in the other groups. Likewise, the mean F− concentration was significantly lower in the unradiated AmF group than in the 7-W diode or 1-W CO2 groups. Finally, the mean F− concentration was significantly lower in the 5-W diode group than in the 1-W CO2 group.
Intrapulpal temperature
Table 2 shows the intrapulpal temperatures obtained according to laser type and power, including initial and final temperatures and the temperature increase in each group, with standard deviations. Data were obtained during laser irradiation, and the internal pulp temperature increase was determined by calculating the difference between initial and maximum temperature values. Results indicate that: (1) the critical temperature increase of 5.5C° was not reached using the 5-W diode laser or the CO2 laser at 1 or 2-W; (2) A temperature above 5.5C° was reached using the 7-W diode laser, although the mean value obtained was below this critical temperature; (3) CO2 laser at 1-W produced the lowest intrapulpal temperature increases.
Discussion
This study evaluated the ability of CO2 and diode laser applications to increase fluoride uptake by enamel. CO2 laser effectively reduces the acid solubility of enamel and, when used in combination with fluoride, increases its fluoride uptake [24]. However, despite the wide utilization of diode lasers in dental practice, their usefulness as coadjuvant in topical fluoridation has been less well studied [15].
In the present study, the fluoride uptake by enamel was higher in groups treated with fluoride and irradiated with CO2 laser than in the control group. Even at a very low power (1-W), a concentration of 89 ± 18 mg/l of fluoride was obtained on the study window, consistent with previous studies, although they reported a larger amount of fluoride on their samples [12, 25]. This discrepancy may be explained by our use of laser in pulsed mode and at a lower power in comparison to the other authors, which would favor thermal relaxation of the enamel and a lower frequency of undesirable effects [26]. In addition, the teeth in the present study were from patients with no experience of a fluoridation program, which might have an influence on the amount of fluoride on their enamel, although this characteristic of the study population was not reported in the other studies. Finally, the meticulous post-treatment cleaning of the surfaces would facilitate detachment of almost all of the fluoride not integrated into the enamel.
The treatment of dental surfaces with diode laser at 5 and 7 W also significantly increased the fluoride uptake (64 ± 16 and 77 ± 17 mg/l) in comparison to the control group (20 ± 1 mg/l). The above laser treatment fluoride concentrations are greater than the group treated with amine fluoride alone (58 ± 7 mg/l), but are not statistically relevant. Although the increase achieved with CO2 laser (89 ± 18 mg/l) was significantly higher than the results obtained with diode laser and amine fluoride alone, they were not statistically different with 7-W treatment. These results are consistent with a previous report by our group [19] of an increase in sodium fluoride (NaF) uptake using the same diode laser settings; although the concentration of fluoride on enamel was lower than in the present study. This may be explained by the more effective fluoridation achieved with AmF than with NaF [27, 28]. At any rate, both the present and the previous investigations demonstrate that the use of laser in this treatment is more effective than conventional fluoridation. Nevertheless, further studies in this field are warranted, since few data are available on the effect of diode laser radiation on dental enamel [20, 21, 29].
Microscopic study of the CO2 laser-treated samples revealed a “frosted glass” type of melting at 1-W power, with signs of heat stress (e.g., exfoliation and cracks) appearing at 2 W. Hence, the objective of effective fluoridation without morphological damage is not achieved with CO2 laser at 2 W. Study of the enamel surfaces treated with diode laser showed no changes to the enamel at 5 W but morphological changes and small areas of surface exfoliation at 7 W, although to a lesser extent than observed with 2-W CO2 laser.
ESEM results were in agreement with the absorption data in hydroxyapatite for laser radiation at the assayed wavelengths. The wavelength of the CO2 laser has a higher absorption coefficient on enamel surface in comparison to that of the diode laser, and it is therefore more likely to affect the surface, even at relatively low powers [30]. This is confirmed by the thermal alteration of specimen surfaces found when CO2 laser was used, with melting at 1 W and exfoliation at 2 W.
The proposition that enamel melting by laser is desirable in order to increase resistance to acid attack has been supported by some authors [9, 31] and opposed by others [13, 32]. We feel closer to the latter group, since the effect does not appear to be uniform and there is a risk of fracture or exfoliation, leaving inner areas of enamel uncovered and unprotected against acids. The fractures and exfoliation areas observed with 2-W CO2 and, to a lesser extent, with 7-W diode laser treatments can facilitate deeper penetration of acids [29], in direct opposition to the objectives of the fluoridation treatment. These defects are caused by the rapid expansion of water vapor in the organic matrix of enamel during laser treatment [33].
Microscopic studies of diode laser-treated surfaces showed small globular agglomerates that may be calcium fluoride (CaF2), according to some authors [24, 34, 35]. This finding was previously reported by our group using NaF [19] but in lower amounts, which may be explained the deeper penetration of amine fluoride into the dental structure. The CaF2 deposited on the enamel may correspond to fluoride that is not integrated into the enamel matrix. However, the deposit does not appear to influence caries prevention, since in vivo studies [36] reported its disappearance after a short time period due to the exchange of ions with oral fluids.
With our experimental laser settings (pulse duration, repetition rate, and exposure time), intra-pulpal temperature measurements indicated that no pulp damage is produced by CO2 laser at a power below 2 W or by diode laser at 5 W or below. However the critical limit of 5.5°C [37] is exceeded with the use of diode laser at 7 W, ruling out its use in clinical practice with these experimental laser settings. However, other laser settings or exposure times could be used with 7 W without increasing the temperature.
In conclusion, CO2 laser at power of 1 W and diode laser at power of 5 W, may both be used as effective methods of dental fluoridation that offer safety in terms of pulpal temperature and enamel surface integrity. However, they must be applied with due caution and at the appropriate laser settings, as in the present experiment. Diode laser, at both experimental settings used, has a lower capacity to integrate fluoride into enamel but also a lower capacity to alter the enamel in comparison to CO2 laser. CO2 laser has a higher absorption coefficient on enamel surface and can cause ablation effects, hence greater caution must be taken with its use in comparison to the diode laser. Fluoride can be integrated into hydroxyapatite with the use of lasers, unlike in conventional topical fluoridation, and further research is warranted on their use.
References
ten Cate JM (2004) Fluorides in caries prevention and control: empiricism or science. Caries Res 38:254–257
Klein ALL, Rodrigues LKA, Eduardo CP, Dos Santos MN, Cury JA (2005) Caries inhibition around composite restorations by pulsed carbon dioxide laser application. Eur J Oral Sci 113(3):239–244
Castellan CS, Luiz AC, Bezinelli LM, Lopes RMG, Mendes FM, Eduardo CDP, De Freitas PM (2007) In vitro evaluation of enamel demineralization after Er:YAG and Nd:YAG laser irradiation on primary teeth. Photomed Laser Surg 25(2):85–90
Apel C, Meister J, Schmitt N, Gräber HG, Gutknecht N (2002) Calcium solubility of dental enamel following sub-ablative Er:YAG and Er:YSGG laser irradiation in vitro. Lasers Surg Med 30(5):337–341
Hossain MM, Hossain M, Kimura Y, Kinoshita J, Yamada Y, Matsumoto K (2002) Acquired acid resistance of enamel and dentin by CO2 laser irradiation with sodium fluoride solution. J Clin Laser Med Surg 20:77–82
Westerman GH, Hicks MJ, Flaitz CM, Ellis RW, Powell GL (2004) Argon laser irradiation and fluoride treatment effects on caries-like enamel lesion formation in primary teeth: an in vitro study. Am J Dent 17(4):241–244
Chen CC, Huang ST (2009) The effects of lasers and fluoride on the acid resistance of decalcified human enamel. Photomed Laser Surg 27(3):447–452
Kuroda S, Fowler BO (1984) Compositional, structural and phase changes in vitro laser-irradiated human tooth enamel. Calcif Tissue Int 36(4):361–369
Steiner-Oliveira C, Rodrigues LKA, Soares LES, Martin AA, Zezell DM, Nobre-Dos-Santos M (2006) Chemical, morphological and thermal effects of 10.6-μm CO2 laser on the inhibition of enamel demineralization. Dent Mater J 25(3):455–462
Hsu CYS, Jordan TH, Dederich DN, Wefel JS (2000) Effects of low-energy CO2 laser irradiation and the organic matrix on inhibition of enamel demineralisation. J Dent Res 79:1725–1730
Schmidlin PR, Dörig I, Lussi A, Roos M, Imfeld T (2007) CO2 laser-irradiation through topically applied fluoride increases acid resistance of demineralised human enamel in vitro. Oral Health Prev Dent 5(3):201–208
Tepper SA, Zehnder M, Pajarola GF, Schmidlin PR (2004) Increase fluoride uptake and acid resistance by CO2 laser-irradiation trough topically applied fluoride on human enamel in vitro. J Dent 32:635–641
McCormack SM, Fried D, Featherstone JD, Glena RE, Seka W (1995) Scanning electron microscope observations of CO2 laser effects on dental enamel. J Dent Res 74(10):1702–1708
Malmstrom HS, McCormack SM, Fried D, Featherstone JDB (2001) Effects of CO2 laser on pulpal temperature and surface morphology: an in vitro study. J Dent 29:521–529
Klim JD, Fox DB, Coluzzi DJ, Neckel CP, Swick MD (2000) The diode laser in dentistry. Wavelengths 8(4):13–16
Sato K (1983) Relation between acid dissolution and histological alteration of heated tooth enamel. Caries Res 17:490–495
Fowler BO, Kuroda S (1986) Changes in heat and in laser-irradiated human tooth enamel and their probable effects on solubility. Calcif Tissue Int 38:197–208
Hirota F, Furumoto K (2003) A hypothesis for acquired acid resistance afforded by the laser irradiation. Int Congr Ser 1248:307–311
Villalba-Moreno J, González-Rodríguez A, López-González JD, Bolaños-Carmona MV, Pedraza-Muriel V (2007) Increased fluoride uptake in human dental specimens treated with diode laser. Lasers Med Sci 22:137–142
Yu DG, Kimura Y, Fujita A, Hossain M, Kinoshita JI, Suzuki N, Matsumoto K (2001) Study on acid resistance of human dental enamel and dentin irradiated by semiconductor laser with Ag(NH3)2F solution. J Clin Laser Med Surg 19(3):141–146
Santaella MR, Braun A, Matson E, Frentzen M (2004) Effect of diode laser and fluoride varnish on initial surface demineralization of primary dentition enamel: an in vitro study. Int J Paediatr Dent 14(3):199–203
Strawn SE, White JM, Marshall GW, Gee L, Goodis HE, Marshall SJ (1996) Spectroscopic changes in human dentine exposed to various storage solutions. J Dent 24:375–377
Kissa E (1983) Determination of fluoride at low concentrations with the ion-selective electrode. Anal Chem 55:1448–1451
Rodrigues LK, Nobre dos Santos M, Pereira D, Assaf AV, Pardi V (2004) Carbon dioxide laser in dental caries prevention. J Dent 32(7):531–540
Chin-Ying SH, Xiaoli G, Jisheng P, Wefel JS (2004) Effects of CO2 laser on fluoride uptake in enamel. J Dent 32(2):161–167
Klocke A, Mihailova B, Zhang S, Gasharova B, Stosch R, Güttler B, Kahl-Nieke B, Henriot P, Ritschel B, Bismayer U (2007) CO2 laser-induced zonation in dental enamel: a Raman and IR microspectroscopic study. J Biomed Mater Res B Appl Biomater 81(2):499–507
Weintraub JA (2003) Fluoride varnish for caries prevention: comparisons with other preventive agents and recommendations for a community-based protocol. Spec Care Dentist 23(5):180–186
ten Cate JM, Buijs MJ, Miller CC, Exterkate RA (2008) Elevated fluoride products enhance remineralization of advanced enamel lesions. J Dent Res 87(10):943–947
Kato IT, Kohara EK, Sarkis JE, Wetter NU (2006) Effects of 960-nm diode laser irradiation on calcium solubility of dental enamel: an in vitro study. Photomed Laser Surg 24(6):689–693
Fried D, Zuerlein M, Featherstone JDB, Seka W (1998) IR laser ablation of dental enamel: mechanistic dependence on the primary absorber. Appl Surf Sci 128:852–856
Nelson DG, Wefel JS, Jongebloed WL, Featherstone JD (1987) Morphology, histology and crystallography of human dental enamel treated with pulsed low-energy infrared laser radiation. Caries Res 21(5):411–426
Esteves-Oliveira M, Apel C, Gutknecht N, Velloso WF, Cotrim MEB, Eduardo CP, Zezell DM (2008) Low-fluence CO2 laser irradiation decreases enamel solubility. Laser Phys 18(4):478–485
Apel C, Schäfer C, Gutknecht N (2003) Demineralization of Er:YAG and Er, Cr:YSGG laser-prepared enamel cavities in vitro. Caries Res 37(1):34–37
Leamy P, Brown PW, TenHuisen K, Randall C (1998) Fluoride uptake by hydroxyapatite formed by the hydrolysis of alpha-tricalcium phosphate. J Biomed Mater Res 42(3):458–464
Yesinowski JP, Mobley MJ (1983) Fluorine-19 MAS-NMR of fluoridated hydroxyapatite surfaces. J Am Chem Soc 105(19):6191–6193
Attin T, Hartmann O, Hilgers RD, Hellwig E (1995) Fluoride retention of incipient enamel lesions after treatment with a calcium fluoride varnish in vivo. Arch Oral Biol 40(3):169–174
Zach L, Cohen G (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 19:515–530
Acknowledgements
The authors are grateful to the Andalusian Environment Centre for the use of microscope and technical assistance, the University of Granada for providing the study materials, Richard Davies for assistance with the English version of this manuscript, and Jose M Rodriguez Toledo for help with the figure depiction of the experimental designs.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
González-Rodríguez, A., de Dios López-González, J., del Castillo, J.L. et al. Comparison of effects of diode laser and CO2 laser on human teeth and their usefulness in topical fluoridation. Lasers Med Sci 26, 317–324 (2011). https://doi.org/10.1007/s10103-010-0784-y
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10103-010-0784-y