Introduction

Current concepts of dentin adhesion include “etch-and-rinse” (ER) or “self-etch” (SE) approaches. An ER approach consists of etching dentin with 32–37% phosphoric acid to remove the smear layer, demineralize superficial dentin, expose the ultrafine collagen mesh, and open dentinal tubules for subsequent adhesive penetration [1]. An SE approach excludes phosphoric acid step and instead relies on acidic monomers in dental adhesive formulation to partially demineralize dentin surface [2].

Universal adhesives, a recently marketed group of dental adhesives, are recommended for adhesion to dental tissues following either approach as well as to materials for indirect restorations without separate priming, hence the term “universal.” Despite reports favoring the SE approach [3, 4], the manufacturers’ recommendations leave it up to the practicing dentist to choose a preferable application strategy for universal adhesives, suggesting that both ER and SE are likely used in current dental practice.

Surface modification by phosphoric acid etching has long been the preferred method of choice for optimizing dentin adhesion, though more complex than that on enamel. The effects of phosphoric acid on dentin are well known from the micro-morphological point of view [1]. However, the reported effects of acid etching on physico-chemical surface characteristics of dentin are contradictory. Attal et al. [5] concluded that acid etching results in a hydrophobic dentin surface while other authors reported increased hydrophilicity of dentin surface [6, 7].

Non-thermal atmospheric plasma (NTAP) is another powerful surface modification tool recently gaining momentum in adhesive dentistry research. NTAP is widely used in material engineering, production of semiconductor devices, integrated circuits, solar cells, etc. [8,9,10,11]. In case of biomedical applications, NTAP may be used for treatment of heat-sensitive samples that cannot withstand vacuum. Also, NTAP or plasma liquid interaction is becoming great interdisciplinary area of research [12]. NTAPs are known for high amounts of reactive oxygen and nitrogen species (RONS) responsible for plasma interactions with biological samples [13,14,15]. In this paper, as an NTAP source, we used a plasma needle constructed and developed in Laboratory for gaseous electronics, Institute of Physics Belgrade, Serbia. The plasma needle was previously used to enable an osteogenic differentiation of human periodontal ligament mesenchymal stem cells (hPDL-MSCs) that can help in cell-based treatment of periodontal defects [16], decontamination of bacteria in planktonic samples and biofilms [17,18,19], and the damage effect of plasma treatment was compared to the effects of ionizing radiation through induced DNA damage [20].

Literature review on NTAP in adhesive dentistry shows that NTAP was previously used to modify surfaces of dental tissues and restorative materials, induce resin polymerization, and facilitate resin penetration and grafting onto collagen [21]. More specifically, NTAP was shown to substantially decrease water contact angles on dentin [22,23,24] with atomic compositional changes in the form of decreased percentage of C and N and increased O, Ca, and P [22]. Similar effects of NTAP on water contact angles were observed on enamel [22, 25], composites [22], and ceramics [26,27,28], suggesting increased hydrophilicity of all these substrates. Argon NTAP increased surface free energy and wettability of root dentin following sodium hypochlorite irrigation [29]. A recent paper [30] found no significant changes in dentin-surface topography after NTAP treatment for clinically relevant times. However, more numerous resin tags and a thinner dentin hybrid layer were visible after NTAP treatment. Enzymatic activity of matrix metalloproteinases was dependent on the NTAP treatment time [30]. Previous studies offered inconsistent evidence on the effects of NTAP on adhesive bond strength to dentin warranting further research [23, 24, 30,31,32,33,34]. An insight into previous studies reveals a non-standardized approach to the use of NTAP with differences regarding carrier gas, power, time, and distance between the plasma source and the treated substrate.

Wetting (wettability) indicates the ability of an adhesive to spread over dentin as a result of the balancing adhesive and cohesive forces. It further contributes to adhesive penetration into collagen interfibrillary spaces and dentinal tubules by capillary forces, thereby improving dentin hybridization as the primary mechanism of adhesion [5]. In dental research, wetting characteristics of a substrate (e.g., dentin) are commonly determined by measuring contact angles of water. Conclusions on adhesive-dentin interaction based only on water contact angles may underestimate the effects of a complex adhesive mixture of polar and apolar, hydrophilic, and hydrophobic components. Taking into account polar and apolar interactions between the liquid and solid, surface free energy (SFE) allows better understanding of the nature of surface interactions between adhesives and dentin.

The aims of this study were to (1) compare the effects of a range of NTAP treatments on wetting and SFE of dentin and (2) compare a selected, most efficient NTAP treatment with ER and SE application protocols for universal adhesives in terms of wetting and SFE of dentin. The following working hypotheses were tested: (1) reduced distance, increased power, and O2 feed in NTAP reduce the contact angles of reference liquids and increase SFE of dentin and (2) compared to ER and SE application protocols, an NTAP treatment results in lower contact angles of reference liquids and universal adhesives and higher SFE of dentin.

Materials and methods

Sample preparation

A total of 278 human, intact, third molars extracted for orthodontic reasons were used in this study. Ethics Committee of the University of Belgrade, School of Dental Medicine approved (Approval No. 36/16) of the use of such teeth in research purposes and teeth were collected with patients’ consent. Following extraction, the teeth were cleaned of debris, stored in 0.2% thymol in a refrigerator at + 4 °C, and used within 3 months of extraction.

Each tooth was embedded in super-hard gypsum up to the enamel-cementum junction. The cusps were cut off using a slow-speed diamond saw (Isomet 4000, Buehler, Lake Bluff, IL, USA) to expose flat dentin mid-coronally. A second cut was made 1 mm below the exposed dentin surface, producing a 1-mm-thick dentin disk, one from each crown/tooth. Dentin disks were wet-polished manually with a 600-grit SiC abrasive paper for 30 s to produce a smear layer.

All dentin disks were allocated to groups and subgroups according to the subsequent treatment and reference liquids used for contact angle measurement, as shown in Table 1. Based on the results for 100% He NTAP, 8-mm tip-to-surface distance was not tested with NTAP with O2 feed to reduce the overall number of groups. Additional disks were prepared for scanning electron microscopy (SEM) analysis.

Table 1 Allocation of teeth to groups and subgroups according to treatments and reference liquids

NTAP treatment

An NTAP source used in this work was the so-called plasma needle [35] which generated non-thermal plasma at 13.56-MHz frequency (Fig. 1). The powered electrode of plasma needle was wolfram wire (outer diameter (o.d.) 0.5 mm) enclosed in a ceramic tube. Both were placed within a glass tube with an inner diameter of 4 mm (outer diameter (o.d.) 6 mm). The glass tube was held in Teflon support. In all experiments, we used helium or a mixture of helium and oxygen as the carrier gas and gas flow was kept constant at 1 slm (standard liter per minute). We used pure He, 99% He + 1% O2, or 98.5% He + 1.5% O2 mixtures. The distances between the treated dentin surface and the tip of the plasma needle were 2, 4, or 8 mm. The applied powers of plasma needle in this experiment were 1 or 3 W. NTAP treatment time was 30 s in all groups. In order to determine the power delivered to the plasma, we used derivative probes developed at the Laboratory for gaseous electronics, Institute of Physics Belgrade, Serbia [36].

Fig. 1
figure 1

Experimental setup of NTAP plasma needle for dentin treatment. (Signal generator, amplifier, and matching box are main components of the electrical circuit that supplies power to the NTAP. The oscilloscope and PC are used to control the power delivered to the NTAP)

Acid etching and adhesive application

To simulate the ER adhesive application protocol, the upper surface of each dentin disk was etched with 32% phosphoric acid (Scotchbond Universal Etchant, 3M ESPE, St. Paul, MN, USA) for 15 s, rinsed under tap water for 15 s, and blot-dried using a cotton pellet (Agava, Prokuplje, Serbia).

To simulate the SE application protocol, dentin disks with the smear layer were blot-dried and used without any additional treatment. Table 2 provides details on the materials used in this study.

Table 2 Materials used in this study

Contact angle measurements and surface free energy calculation

The sessile drop technique was used to measure contact angles of three reference liquids: distilled water, ethylene glycol (Sigma-Aldrich, St. Louis, MO, USA), and diiodomethane (Acros Organics, Fairlawn, NJ, USA). Following the ER and SE protocols, universal adhesives SBU and CUB were also used for contact angle measurements.

The experiment was so designed that NTAP treatment or acid etching and contact angle measurement were performed under the same temperature (23.3 ± 0.3 °C) and humidity (34.1% ± 1.5%) conditions. Immediately after NTAP or acid etching treatment, the samples were transferred onto the contact angle measurement bench, so they remained still partially wet. A pre-set amount of liquid (2 μl) was dispensed from a micropipette (BIOHIT, BiohitOyj, Helsinki, Finland) onto dentin surface at a 90° angle and 4-mm distance. The contact angles (θ) of reference liquids and universal adhesives were recorded using a contact angle analyzer 1 s after the drop touched dentin surface and measured using ImageJ software (version 1.42, National Institute of Health, USA). Contact angle analyzer was constructed at the Institute of Physics to allow the abovementioned standard conditions (Fig. 2). The setup included a DSLR Nikon D7100 camera with mounted Nikkor Macro lens 105 mm f2.8 D, Nikon SB910 flashlight, and position stand. Camera in relation to the sample was adjusted using a tripod with built-in libel so it was always in the horizontal plane with the sample holder.

Fig. 2
figure 2

Schematic of the contact angle analyzer setup and representative images of dentin disks with reference liquid drops. a Water on NTAP-treated dentin. b Water on phosphoric acid-treated dentin. c Water on untreated dentin

SFE (γ) calculation was based on van Oss-Chaudhury-Good thermodynamic approach for solids and the three-liquid phase method. According to this theory, both apolar and polar interactions occur at the interface between liquid and solid materials [37]. Apolar interactions occurring between two completely apolar compounds are known as Lifshitz-van der Waals interactions. A component of SFE of compound i based on strictly apolar interactions is expressed as Lifshitz-van der Waals component or \( {\gamma}_i^{LW} \). Polar interactions are largely based on hydrogen-bonding or electron acceptor-electron donor (Lewis acid-base) interactions between polar moieties. These Lewis acid-base interactions are asymmetrical, so electron acceptor and electron donor parameters of the polar component of SFE of compound i are expressed as \( {\gamma}_i^{+} \) and \( {\gamma}_i^{-} \) [37]. SFE of a solid (γS) and its components (apolar \( {\gamma}_S^{LW} \), Lewis acid \( {\gamma}_S^{+} \), and Lewis base \( {\gamma}_S^{-} \)) are calculated using the contact angles (θ) of three reference liquids with their known SFE parameters (\( {\gamma}_L^{LW} \), \( {\gamma}_L^{+} \), and \( {\gamma}_L^{-} \)) according to the following formula:

$$ \left(1+ cos\theta \right){\gamma}_L=2\left(\sqrt{\gamma_S^{LW}{\gamma}_L^{LW}}+\sqrt{\gamma_S^{+}{\gamma}_L^{-}}+\sqrt{\gamma_S^{-}{\gamma}_L^{+}}\right) $$

where the SFE of liquid equals the sum of SFE components (apolar Lifshitz-van der Waals and polar acid-base) according to the rule of additivity:

$$ {\gamma}_L={\gamma}_L^{LW}+{\gamma}_L^{AB} $$

(with) \( {\gamma}_L^{AB}=2\sqrt{\gamma_L^{+}{\gamma}_L^{-}} \)

By solving the van Oss-Chaudhury-Good equation three times for three reference liquids, it is possible to differentiate between polar and apolar surface interactions and between Lewis acid and Lewis base polar interactions of a tested solid. Though reference liquids may vary, two of them must be polar [37]. In the present study, water and ethylene glycol were used as polar and diiodomethane as apolar liquid with known SFE parameters [38, 39].

SEM

Representative samples from NTAP, acid-etched, and control groups (eight teeth in total) were subjected to SEM to analyze the differences in surface micro-morphology. Without prior dehydration treatment, the samples were mounted on aluminum stubs, fixed with graphite conductive tape, subjected to vacuum in a sputter coater (POLARON SC502, Fisions Instruments, Ipswich, UK), and then coated with a thin film of Au alloy. The samples were analyzed using TESCAN FE-SEM (Mira 3 XMU, TESCAN a.s., Brno, the Czech Republic) operating at 10 keV.

Statistical analysis

All data were statistically analyzed in Minitab 16 software package (Minitab Inc., State College, PA, USA) with the level of significance set at 0.05. To test the differences in contact angles for each reference liquid, general linear model (GLM) was applied for factors “plasma,” “power,” and “distance” as well as their interactions. To test the differences in dentin SFE, GLM was applied using the same factors. Where the interaction was significant, further one-way analysis of variance (ANOVA) with Tukey’s post hoc test and Bonferroni correction was used. Differences in contact angles and SFE between the selected NTAP treatment, ER, and SE protocols were tested using one-way ANOVA with Tukey’s post hoc test. Equal variances were tested using Bartlett’s and Levene’s tests, and where necessary, data transformation was applied to stabilize the differences in variances. Quadratic, logarithmic, or sqrt functions were used for data transformation.

Results

Screening of NTAP treatment regimes

Figure 3 presents the box-and-whisker plots of contact angles of reference liquids following an array of NTAP treatments. GLM analyses showed that all NTAP treatments significantly reduced the contact angles of all three reference liquids compared to the untreated control group (p ≤ 0.001). The results were most prominent for water with contact angles decreasing from 84.2° ± 2.6° in the control group to the range of 6–30° in the NTAP-treated group with the exception of 100% He_1W_8mm group (where the post-treatment contact angle was 69.1° ± 5.6°). Though contact angles for ethylene-glycol and diiodomethane were similar in the control group (36.6° ± 5.3° and 37.9° ± 1.9°, respectively), NTAP treatment decreased the ethylene glycol contact angle (5–12° range) to a greater extent than that of diiodomethane (10–30° range).

Fig. 3
figure 3

Summary of the contact angle data for the three reference liquids on NTAP-treated dentin. (Same-type letters or symbols indicate statistical significance within each respective group (p > 0.05); N = 5 samples/group)

GLM analyses for factors plasma, power, and distance showed that O2 feed further decreased contact angles of water compared to pure He NTAP (p ≤ 0.001). There was no difference between 1 and 1.5% O2 in the resulting contact angles of water. Such effects of NTAP with O2 feed were not observed with ethylene-glycol and diiodomethane (p = 0.183 and p = 0.094, respectively).

NTAP power of 3 W significantly reduced contact angles of water and diiodomethane as compared to 1 W power (p ≤ 0.001), but this effect was not found for ethylene glycol (p = 0.08). Tip-to-surface distances of 2 and 4 mm did not produce any significant differences in contact angles of reference liquids (water p = 0.068, ethylene glycol p = 0.109, and diiodomethane p = 0.454). For 8-mm distance, 100% He NTAP at 1 W resulted in significantly higher water contact angles than other groups (p ≤ 0.001). Therefore, we excluded 8-mm tip-to-surface distance from the NTAP treatments with O2 feed. Within-group differences were detected using one-way ANOVAs statistical test and are marked with letters and symbols in Fig. 3.

Regarding SFE, significantly higher SFE of NTAP-treated dentin was found than that of the untreated group (Fig. 4). Moreover, NTAP with O2 feed further increased the SFE of dentin compared to 100% He NTAP (p ≤ 0.001). No differences were found between NTAPs with 1 and 1.5% O2 (p = 0.357).

Fig. 4
figure 4

Surface free energy (SFE) of dentin following various treatments (mean and standard deviation). (Same-type letters or symbols indicate statistical significance within each respective group (p > 0.05))

For the same NTAP source, higher SFE of dentin was associated higher power for pure He and He + 1% O2 NTAPs, i.e., 3 W, resulting in higher SFE than 1-W treatment (p ≤ 0.001). Conversely, different powers of NTAP with 1.5% O2 feed had no effect on the SFE of dentin (p = 0.09), except for 1W_4mm group which resulted in slightly lower SFE of dentin compared to 3W_4mm (p = 0.013).

In general, the tip-to-surface distance did not affect the SFE of NTAP-treated dentin (p = 0.514), with exceptions being 100% He_1W_8mm and He+1.5%O2_1W_4mm, which showed significantly lower SFE than their corresponding groups (p ≤ 0.001 and p = 0.007, respectively) (Fig. 4).

Component analysis of SFE is presented in Fig. 5. In the control group (untreated dentin), apolar component of SFE appeared more prominent than the polar component, of which Lewis acid was predominant. NTAP treatments, except for the less effective 1W_8mm of pure He NTAP, all showed rather similar effects; i.e., polar component substantially increased compared to the control, and apolar component also slightly increased. Within the polar component of SFE in NTAP-treated dentin, Lewis base surpassed Lewis acid component. Compared to the control untreated dentin, Lewis base and apolar components increased whereas Lewis acid component decreased.

Fig. 5
figure 5

Polar (Lewis base and Lewis acid) and apolar components of surface free energy on NTAP-treated and untreated, control dentin. The tested groups are presented on the x axis (100% He NTAP at 1 W, 2 mm; 100% He NTAP at 1 W, 4 mm; 100% He NTAP at 1 W, 8 mm; etc.)

Comparison of NTAP with ER and SE protocols for universal adhesives

Based on the previous screening, the following NTAP treatment was chosen for the next part of the study: He+1.5%O2_3W_4mm. Contact angle measurements for three reference liquids and the subsequent SFE calculation were performed for NTAP-treated, acid-treated, and untreated dentin. Universal adhesives SBU and CUB were used only to measure their contact angles on NTAP-treated, acid-treated, and untreated dentin. It was not possible to calculate the SFE of dentin using adhesives as SFE may only be calculated using reference liquids (water, ethylene glycol, and diiodomethane).

Contact angles of all reference liquids were lower on NTAP-treated than on acid-treated or untreated dentin (p ≤ 0.001) (Fig. 6). Phosphoric acid etching produced significantly lower water contact angles compared to the untreated, control group (p ≤ 0.001), but the same effect was not found for ethylene-glycol and diiodomethane (p = 0.069 and p = 0.120, respectively).

Fig. 6
figure 6

Contact angle values (mean and standard deviation) for reference liquids and universal adhesives following different dentin treatments (group name: treatment_liquid). “Control” denotes untreated dentin. Groups “SBU” (Single Bond Universal) and “CUB” (Clearfil Universal Bond) present contact angle values of the respective adhesive following the self-etch application protocol. (Groups connected with horizontal bars are not significantly different (p > 0.05))

As for universal adhesives, higher contact angles of SBU and CUB (44.13 ± 8.45° and 33.04 ± 6.04°, respectively) were found on acid-treated than untreated dentin (29.94 ± 1.86° and 26.56 ± 2.33°, respectively) (SBU p = 0.003 and CUB p = 0.009, respectively). Slightly lower contact angles of SBU and CUB were measured on NTAP-treated dentin (35.68 ± 2.35° and 19.96 ± 6.89°, respectively) compared to acid-etched dentin, but the differences reached statistical significance only for CUB (p = 0.015). NTAP-treated and untreated dentin showed no significant differences in contact angles of universal adhesives (p = 0.808).

The SFE of dentin was highest on NTAP-treated and lowest on untreated dentin (Fig. 7). NTAP and acid etching increased polar, Lewis base, and decreased Lewis acid component as compared to the untreated dentin. NTAP increased and acid etching decreased apolar component of SFE compared to that of untreated dentin.

Fig. 7
figure 7

Surface free energy (SFE) and its polar (Lewis acid and Lewis base) and apolar components

SEM micro-morphological analysis

Representative SEM micrographs are presented in Fig. 8. Phosphoric acid etching removed the smear layer, exposed the collagen mesh, and opened dentinal tubules. No visible micro-morphological differences were found between NTAP-treated and untreated dentin (control group), which was only ground with 600-grit SiC abrasive paper to produce the smear layer.

Fig. 8
figure 8

SEM micrographs of dentin following different treatments. All three NTAP treatments had the same parameters (3 W and 4 mm) but differed in O2 feed. Dentin was acid etched for 15 s. No treatment was performed in the control group

Discussion

The first working hypothesis was upheld; i.e., all NTAP regimes reduced contact angles of reference liquids and increased SFE of dentin compared to the untreated dentin with further detectable differences relative to the tip-to-surface distance, power, and O2 feed.

He and Ar are commonly used carrier gases in NTAP studies on dental tissues with powers generally higher (5–10 W) than in the present study (1 and 3 W). A comparable power of 2–3 W was used in the study by Zhang et al. [40], who used Ar-based NTAP to study adhesive penetration into demineralized dentin. Our intention was to optimize He-based NTAP regimes with lower powers for use on dentin in order to minimize the effect of heating and potential dentin cracks observable with higher-powered NTAPs. Furthermore, the chosen time and tip-to-surface distances are clinically relevant and manageable. Up to 10% O2 feed was added to NTAPs used for microbial disinfection [41], whereas lower, up to 1%, O2 was added to NTAP for dentin and root canal treatment [42]. We used 1 and 1.5% O2 feed to investigate if slightly higher O2 feed would intensify the effect of NTAP. The results indicated that while O2 generally intensified the effects of NTAP on wetting and SFE of dentin, there was little or no difference between 1 and 1.5% O2, suggesting that there may be a “saturation” effect of O2 feed in NTAP. In the study of Koban et al. [42], significant differences in water contact angles were found between Ar NTAP with 0.2 and 1% O2. These findings indicate that O2 feed as low as 0.2% may be disregarded and pure carrier gas used for plasma treatment. If O2 is to be added to NTAP, the present results suggest that 1–1.5% O2 may be recommended.

All NTAP regimes significantly reduced the contact angles of reference liquids, especially water, and increased SFE of dentin compared to the untreated dentin, indicating a dramatic increase in dentin wetting. The finding of lower contact angles of reference liquids was expected and is in accordance with previous studies [22,23,24,25]. Moreover, the same effects were achieved in the present study with lower-powered NTAPs (1 W) at clinically relevant distances that allow focusing the NTAP needle on small cavities, e.g., “slot,” class III and V and minimally invasive class I cavities.

A significant decrease in water contact angle was coupled with a greater decrease in the contact angle of ethylene glycol than diiodomethane. NTAP induced a greater change with polar substances (water and ethylene glycol) than apolar diiodomethane, suggesting that a major change on dentin surface was related to hydrophilic and polar interactions. This finding was corroborated by the SFE component analysis, in which polar component increased substantially following the NTAP treatment. A change in acid-base interaction was also detected following the NTAP treatment with an increase in Lewis base component. This further suggests that more negatively charged sites appear on the surface of the NTAP-treated dentin for potential interactions with electron-accepting molecules, such as acidic monomers from adhesives.

Our SFE component analysis is in accordance with previous spectroscopic (XPS and FTIR) studies which reported grafting polar, oxygen-containing moieties on NTAP-treated surfaces as a result of an intense attack of reactive oxygen species. Namely, Chen et al. [22] found an increased percentage of O in dentin and enamel, Ritts et al. [32] found increased carbonyl C=O groups on collagen, and Lehmann et al. [25] reported on increased carboxylate CO2− and carbonate CO32− ions on the surface of enamel. Beside negatively charged ions with clear affinity for reaction with Lewis acids (electron acceptors), C=O group also contributes to surface reactivity. C=O group is moderately polar, considering the differences in electronegativities of C and O, with affinity for interactions between O and Lewis acids/electron acceptors (e.g., H+) or C and Lewis bases/electron donors (e.g., NH3 or OH). The present results suggest that O2 feed in NTAP further increases polar, specifically Lewis base, interaction sites compared to pure He NTAP. Higher-powered NTAPs further intensified this effect of O2 feed.

Based on the screening of an array of NTAP treatments, we chose He + 1.5% O2 NTAP at 3-W power and 4-mm tip-to-surface distance as the NTAP treatment in the second part of the study. Here, we compared the effects of the said NTAP treatment with phosphoric acid etching representing the ER protocol and no treatment representing the SE protocol of adhesive application. Two universal adhesives were chosen, SBU and CUB. According to manufacturers’ technical data sheets, both SBU and CUB are ethanol- and water-based adhesives, containing BisGMA, HEMA, and 10-MDP monomers. CUB is claimed to contain a highly hydrophilic acidic amide monomer for improved wetting and adhesive penetration, yet the manufacturer did not disclose its name and chemical structure.

The second working hypothesis was partially upheld as NTAP induced greater SFE of dentin and lower contact angles of reference liquids compared to phosphoric acid etching (ER protocol) but had a limited effect on universal adhesives in relation to the SE application protocol.

The results showed that both NTAP and phosphoric acid significantly increase wetting of the treated dentin surface, this effect being more pronounced with NTAP. While NTAP significantly reduced the contact angles of all three reference liquids, phosphoric acid did so only with water whereas ethylene glycol and diiodomethane contact angles were not significantly different from those on untreated dentin. Increased wetting of dentin surface following phosphoric acid etching is in accordance with previous studies [6, 7]. Furthermore, our SFE component analysis revealed that untreated dentin exhibited both apolar and polar sites with predominant Lewis acid electrostatic component. As is customary in dental studies, the “untreated” dentin refers to mid-coronal dentin cut with a diamond saw and ground with 600-grit SiC abrasive paper to produce a smear layer of various thicknesses. Thus, surface characteristics relate to the smear layer which is essentially an amorphous layer of inorganic-organic debris containing hydroxyapatite, collagen, and microbial remnants [43]. Electrostatic Lewis acidity of the dentin smear layer is likely associated with the abundance of Ca2+ ions from hydroxyapatite and contributes to the interaction of phosphate or carboxylate ions with the smear layer and dentin itself during acid etching with phosphoric acid or acidic monomers in adhesives.

Despite its effect on water, phosphoric acid etching significantly increased the contact angles of universal adhesives, SBU and CUB, compared to the untreated dentin where SBU and CUB were applied following the SE protocol. This finding highlights the importance of the present approach based on three reference liquids and SFE component analysis to elucidate the true interaction between adhesives and dentin. Though phosphoric acid etching increased surface hydrophilicity, it did not contribute to wider adhesive distribution over etched dentin compared to adhesive distribution on un-etched dentin. This could be due to the presence of hydrophobic monomers in both adhesives, namely, BisGMA, and the subsequent phase separation between hydrophobic and hydrophilic monomers within the hybrid layer [44, 45]. Phosphoric acid etching decreased the apolar component of dentin SFE, further contributing to the depleted interaction between apolar adhesive components and dentin surface. Though ether (R-O-R) and hydroxyl (R-OH) linkages in monomers exert some polarity, the majority of spacer groups in hydrophobic monomers contribute to low polarity or apolarity [46]. Slightly decreased apolar component of SFE could explain why the only apolar reference liquid, diiodomethane, exerted increased contact angle on acid-etched dentin.

Both NTAP and phosphoric acid etching resulted in an increase of electrostatic Lewis base component. Increased grafting of polar, oxygen-containing groups was previously discussed for NTAP treatment. As for acid etching, Lehmann et al. [25] detected C=O groups and CO2− and CO32− ions at enamel surface following acid etching using XPS analysis. A similar increase in polar, oxygen-containing moieties at dentin following acid etching could be the reason for increased Lewis base sites as found in the present study. This may favor the subsequent interaction of electron acceptors, or Lewis acids, and contribute to hydrogen bonding between adhesive resins and dentin substrate.

NTAP treatment of dentin prior to adhesive application resulted in lower contact angles of SBU and CUB adhesives compared to those on the acid etched dentin, suggesting better adhesive distribution following NTAP treatment. A more favorable effect of NTAP than phosphoric acid in terms of adhesive distribution could be due to the increased surface reactivity of dentin as indicated by increased both apolar and polar (Lewis acid and Lewis base) interaction sites.

Increased surface reactivity and hydrophilicity are likely reasons for lower contact angles of CUB adhesive on NTAP-treated than untreated dentin. The presence of a hydrophilic amide dimethacrylate monomer in CUB, in addition to hydrophilic HEMA, may have contributed to this finding. The effect of NTAP on adhesive contact angle appeared to be material-dependent as NTAP did not facilitate the distribution of SBU adhesive compared to the untreated dentin as it did with CUB. Further research is therefore required to elucidate the adhesive-dentin interactions following NTAP treatment.

Though positive effects of NTAP on adhesive penetration were documented, adhesive phase separation was found in NTAP-treated dentin in a previous study [40]. NTAP increased the penetration of hydrophilic but not hydrophobic monomers within the hybrid layer, limiting the positive effects of NTAP. Phase separation within the hybrid layer due to increased penetration of hydrophilic monomers increases the risk of creating areas more susceptible to water sorption, as hydrophilicity was found to be the prime factor determining the extent of water sorption [47, 48]. In turn, water sorption promotes faster biodegradation of adhesive itself [48] as well as adhesive-dentin bond [49, 50]. This could be the reason for the lack of long-term effect of NTAP on adhesive bond strength despite positive effects on immediate bond strength [23, 24, 33, 34, 51, 52].

The present qualitative SEM analysis revealed no micro-morphological differences between untreated and NTAP-treated dentin. Previous studies also reported no structural differences in the appearance of NTAP-treated dentin/enamel, hence no destructive effects of NTAP [22, 25, 42]. NTAP does have a potential not only to chemically interact with the surface but also to increase surface roughness of dentin by etching [21]. However, this roughening effect was not as notable as with phosphoric acid [25] due to the selective etching of the organic phase by NTAP and not the mineral phase, which was confirmed by elemental analysis [22]. Under the present experimental conditions, no etching effect of NTAP occurred on dentin surface.

Conclusion

He NTAP with and without O2 substantially increased dentin wetting and SFE, surpassing the effect of phosphoric acid etching. O2 intensified the effect of He NTAP at 1- and 3-W powers and clinically relevant distances of 2 and 4 mm. Surface modification of dentin following NTAP treatment included increased hydrophilicity, polarity, and electrostatic Lewis-base interaction sites. Phosphoric acid etching did not favor adhesive distribution on dentin surface as indicated by increased contact angles of universal adhesives, SBU and CUB, despite decreasing water contact angle compared to the untreated dentin. NTAP treatment of dentin prior to adhesive application facilitated better adhesive distribution compared to acid-etched dentin. However, NTAP did not show an improvement regarding the adhesive distribution on dentin compared to the SE protocol of application. Under the present conditions, the effects of NTAP were mainly related to surface modification, with no etching ability but also no structural damage on the dentin surface.