Abstract
The aim of this clinical trial was to evaluate the effects of application mode on the clinical performance of a two-step etch-and-rinse adhesive in class V cavities over 24 months. Forty patients with at least three similar-sized non-carious cervical lesions participated in this study. A total of 120 restorations with Prime & Bond NT were placed, 40 in each group. The adhesive was applied with no rubbing action, with slight rubbing action, or with vigorous rubbing action. The restorations were placed incrementally using the composite resin Esthet-X. The restorations were evaluated at baseline and after 6, 12, and 24 months following the modified United States Public Health Service criteria. Statistical analysis was conducted using Friedman repeated measures analysis of variance by rank and using the Wilcoxon signed-rank test for significance at each pair (α = 0.05). The 24-month retention rates of Prime & Bond NT were 82.5% for the no rubbing group, 82.5% for the slight rubbing group, and 92.5% for vigorous rubbing group. No significant difference in the retention rates in each recall period was detected among groups (p > 0.05); however, the retention rates in the 24-month recall was statistically lower than the baseline only for no rubbing or slight rubbing groups. The use of a vigorous application mode can be a clinical approach to improve the retention of restorations placed in non-carious cervical lesions.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Most currently marketed adhesive systems have immediate bond strength that allows clinicians to bond to tooth structure without the use of retentive cavity preparations. Nevertheless, major concerns have been recently expressed regarding interfacial aging due to degradation of the bonding interface. Interestingly, the simplified adhesives produced the least predictable clinical performances when compared with the three-step etch-and-rinse systems [1–3].
The inferior durability of the simplified etch-and-rinse systems can be attributed to several reasons. The most important is that the adhesive layer is intrinsically more hydrophilic as solvents and hydrophilic components from the primer are mixed in a single bottle with the hydrophobic monomers from the bonding agents [4]. This hydrophilicity turns the adhesive’s semi-permeable membranes even after polymerization [5] with an increased potential to absorb water from the underlying dentin and from the oral cavity [6] and therefore more prone to degradation over time [1].
Various clinical procedures were proposed to optimize bonding and reduce aging, such as prolonged application times of adhesives [7, 8], warm air-dry for solvent evaporation [9], improved impregnation by means of electric impulse-assisted adhesive application [10, 11], use of metaloproteinases inhibitors as chlorhexidine [12–14], and application of selective collagen cross-linkers during adhesive restorative procedures [15]. Besides that, a recent laboratory investigation has demonstrated that simplified etch-and-rinse adhesives can achieve high immediate and 6-month resin–dentin bond strength values when they are vigorously rubbed on the demineralized dentin surface [16, 17].
Whether or not the benefit of this clinical approach can improve the retention rates of simplified etch-and-rinse adhesives when used in non-carious cervical lesions is yet to be determined and needs in vivo validation. Therefore, the aim of the present study was to conduct a 24-month randomized controlled prospective study to evaluate the effect of vigorous rubbing action of a two-step adhesive in non-carious cervical lesions. The null hypothesis to be tested is that no significant difference will be detected among the different modes of application in any of the recall periods.
Materials and methods
The materials employed in this study were Prime & Bond NT, an acetone-based two-step etch-and-rinse adhesive system (Dentsply DeTrey, Konstanz, Germany), and one microhybrid composite resin Esthet-X (Dentsply DeTrey, Konstanz, Germany). Detailed compositions and modes of the application are described in Table 1.
The protocol and consent form for this study were reviewed and approved by the local Committee on Investigations Involving Human Subjects (083/2006). Written informed consent was also obtained from all participants prior to starting the treatment. Patient screening and pretreatment selection of teeth with cervical lesions identified visually or tactilely were performed by four calibrated operators. The patients were screened initially to determine if they met the study entry criteria (described below). Qualified patients were recruited in the order in which they reported for the screening session, thus forming a convenience sample. The investigators carried out the evaluations using a mouth mirror, an explorer, and a periodontal probe. Air from the air–water syringe was used to administer the sensitivity test.
All participants were healthy and had at least 20 teeth. Participants were given oral hygiene instructions before operative treatment. Patients with severe or chronic periodontitis or heavy bruxism were not included in the study group as they required other treatment before any restorative intervention. At least three similar-sized cervical lesions (erosion/attrition/abfraction) under occlusion were required per patient.
The lesions had to be expulsive with no undercuts, and no more than 50% of the cavosurface margin could involve enamel. The cervical wall had to be located in cementum. Lesions not classified as criteria 2 and 3 of dentin sclerosis and exhibiting hypersensitivity were excluded from the study [18].
Restorative procedures
All lesions were restored by the same two investigators that participated in the patient screening. Calibration of operators was carried out by one experienced clinician. Operators first observed the detailed application procedures in laboratory models (3× for each protocol) and then performed four repeated restorations (for each protocol) under direct supervision in a clinical set with patients. Questions were addressed and consensus obtained during the calibration session.
Each patient received three restorations, in which the materials were randomly allocated. Randomization of the materials was performed on each patient by the Excel software (Excel 2003, Microsoft Corporatin, One Microsoft Way, Redmond, WA, USA). The lesions were prepared as follows: (1) local anesthesia (Citanest, Dentsply, Petrópolis, RJ, Brazil), (2) cleaning with pumice and water (SS White Prod. Odontol. Ltda, Petrópolis, RJ, Brasil) in a rubber cup (# 8040RA and 8045RA, KG Sorensen, Barueri, SP, Brasil) followed by rinsing and drying, (3) shade selection (Esthet-X shade guide/Dentsply Caulk, Milford, DE, USA), (4) rubber dam isolation (SS White Prod. Odontol. Ltda, Petrópolis, RJ, Brasil), and (5) rinsing with a water/air spray. No additional retention or bevel was performed.
Then the adhesive Prime & Bond NT (Dentsply Caulk, Milford, DE, USA) was applied under three different modes, as described previously by Dal-Bianco et al. [16].
-
1.
No rubbing action: In this group, the adhesive was only spread over the entire surface for approximately 3 s and left undisturbed for 7 s. Then, an air stream was applied for 10 s at a distance of 20 cm.
-
2.
Slight rubbing action: The adhesive was lightly spread on the entire surface for approximately 10 s; however, no intentional manual pressure was exerted on the microbrush. Before performing the adhesive application, the operator trained on the surface of an analytical balance to determine the equivalent manual pressure that would be placed on the surface of the demineralized dentin (Mettler, type H6; Columbus, OH, USA). For this group, the pressure was equivalent to approximately 4.0 ± 1.0 g. An air stream was applied for 10 s at a distance of 20 cm.
-
3.
Vigorous rubbing action: The adhesive was rigorously agitated on the entire dentin surface for approximately 10 s. The microbrush was scrubbed on the dentin surface under manual pressure (equivalent to approximately 34.5 ± 6.9 g). An air stream was applied for 10 s at a distance of 20 cm (Table 1).
In all these three groups, a second coat of adhesive layer was applied in the same manner as for the first layer. The time lapse from the beginning of the adhesive application and light curing (QHL75 Lite, Dentsply, Petrópolis, RJ, Brazil; 600 mW/cm2) was approximately 40 s. The light curing was performed for the respective recommended time (10 s). Before the start of the clinical placement of the restorations, operators were trained in a laboratory setting in order to standardize the material application according to the three different modes. After adhesive application, lesions were incrementally filled with Esthet-X (Dentsply DeTrey, Konstanz, Germany; ±3 increments). The size of the increment was dependent on the cavity size; however, they never exceeded 1.0 mm. Each increment was light cured for 30 s using a VIP light unit set at 600 mW/cm2 (QHL75 Lite, Dentsply, Petrópolis, RJ, Brazil). All restorations were finished with fine grain diamond burs (# 1190F and 2135F, KG Sorensen, Barueri, SP, Brazil). After 1 week, restorations received a final polishing with Enhance points associated with Prisma Gloss (Dentsply, Petrópolis, RJ, Brazil).
Clinical evaluation
The categories evaluated were retention and marginal discoloration, post-operative sensitivity, and recurrent caries according the US Public Health Service (USPHS) [19] criteria at baseline and after 6, 12, and 24 months. Restoration retention rates were calculated using the ADA Guidelines equation [20].
PF is the number of previous failures before the current recall, NF the number of new failures during the current recall, and RR the number of restorations recalled for the current recall. Photographs were taken prior to the beginning of the treatment, at baseline and at each recall period.
Two other experienced and calibrated examiners performed the evaluation using a mirror and an explorer after teeth prophylaxis. The clinicians were unaware of which adhesive protocol was followed. Each examiner evaluated the restoration once and independently. Consensus was reached when disagreements occurred before dismissing the patient.
Statistical analysis
For sample size calculation, the retention rate of Prime & Bond NT at 24 months was considered to be 98% [18, 21, 22]. Using an α of 0.05, a power of 80%, a one-sided test, the minimal sample size should be 40 restorations in each group in order to detect a difference of 20% between groups [23].
Descriptive statistics were used to describe the frequency distributions of the evaluated criteria. Statistical analysis was made with Friedman repeated measures analysis of variance by rank and using the Wilcoxon signed-rank test for significance at each pair (α = 0.05). The Bonferroni correction was applied for corrections of p value for the multiple comparisons performed. Cohen’s Kappa statistic was used to test the inter-examiner agreement.
Results
All patients attended the recall periods. Forty out of 118 evaluated patients met the inclusion criteria. One hundred and twenty restorations were placed, 40 for each group. The age and gender distribution of the research subjects are presented in Table 2. Fifty-nine restorations were placed in maxillary teeth and 61 in mandibular teeth. Approximately 62% of restorations were placed in premolars and molars, and 38% were placed in anterior teeth (Table 2).
The overall Cohen’s Kappa statistics (0.90) showed excellent agreement between the examiners. All research subjects were evaluated in the 6-, 12-, and 24-month recalls. All patients attended the 24-month recall. A representative clinical case can be seen in Fig. 1.
No restorations presented secondary caries throughout the evaluation period (Table 3). Ten restorations presented post-operative sensitivity in the baseline. After 6 months, nine restorations, three for each group, showed post-operative sensitivity. No post-operative sensitivity was reported in the 12- and 24-month recalls (Table 3).
No interfacial staining was found in the 6-month recall. After 12 months, eight restorations were scored as bravo in marginal discoloration. No significant difference among groups was detected in the 12-month recall (p > 0.05) or when compared to their respective baseline scores (p > 0.05). In the 24-month recall, 13 restorations were scored as bravo in marginal discoloration. The application modes were not statistically different with one another (p > 0.05) in this recall period. When these figures were compared to their respective baseline records, statistical differences were only observed for no rubbing and slight rubbing groups (p = 0.003; Fig. 2). The marginal discoloration occurred mostly at the enamel margin.
The retention rates of the groups at each recall period are depicted in Fig. 3. No significant difference in the retention rates in each recall period was detected among groups (p > 0.05). The comparison of 6- and 12-month vs. baseline findings for all groups did not depict any significant difference (p > 0.05). However, when the 24-month was compared to baseline, significant differences were detected for no rubbing and slight rubbing groups (p = 0.002 for both comparisons), meaning that the retention rates in the 24-month recall was statistically lower than the baseline only for no rubbing and slight rubbing groups.
Discussion
Based on the results of the present investigation, we need to reject the null hypothesis. The use of a vigorous application mode increased the retention rates of the adhesive tested. Since bonding is created by the impregnation of the dentin substrate by blends of resin monomers, the stability of the bonded interface relies on the creation of a compact and homogenous hybrid layer. In the etch-and-rinse strategy, after the preliminary etching to demineralize the substrate, bonding monomers impregnate the porous etched substrate [4, 24]. Thus, theoretically stable bonds can be achieved if the etched substrate is fully infiltrated by a strong polymer network to avoid different degrees of incomplete impregnation [25, 26] and exposure of collagen fibrils at the base of the hybrid layer [27]. However, it is of widespread knowledge that using manufacturers’ protocols, resin monomers, mainly those with high molecular weight from simplified etch-and-rinse adhesives, have limited diffusion into the wet demineralized dentin [25, 26, 28], producing a gradient resin penetration with the highest concentration at the surface of the adhesive, lower concentration in the middle of the hybrid layer, and little resin in deepest portion of the demineralized zone [25, 26, 28].
As bond strength and durability seems to rely on the quality of the hybrid layer (i.e., on the proper impregnation of the dentin substrate), this study investigated the effect of a clinical approach supposed to improve monomer infiltration on the retention rates of an acetone-based simplified etch-and-rinse adhesive. Previous laboratory findings [16, 17] have reported that vigorous rubbing application was capable to increase both the immediate and the 6-month bond strengths compared to slight and inactive applications. A similar trend was observed in the present clinical trial. Although the retention rates of the different application modes did not differ significantly after 24 months, the retention rate of vigorous rubbing group at 24 months (92.5%) was similar to baseline (100%), while they were lower than baseline for the other two techniques (no rubbing (82.5/100%) and slight rubbing (82.5/100%) groups). The range of retention rates found in this study for Prime & Bond NT is very close to what has been previously published after 1 or 2 years of clinical service [18, 29–31].
It is likely that mechanical pressure applied to the demineralized dentin surface during the rubbing action might compress the collagen network like a sponge. As the pressure is relieved, the compressed collagen expands, and the adhesive solution may be drawn into the collapsed collagen mesh [32]. Besides that, the vigorous rubbing action can increase the moieties kinetics and allow better monomer diffusion inward, while solvents diffuse outward. The removal of residual water or solvents increases the mechanical properties of the resin inside the hybrid layer [33–35], and consequently, the mechanical properties of the cured adhesive resin. It was already reported that the ultimate tensile strength of cured adhesives correlates positively with their corresponding resin–dentin bond strengths [36, 37].
The reduction of the amount of solvent retention within the polymer network may also account for reduced water sorption, solubility, and water diffusion coefficients [38]. Water sorption can reduce the durability of a polymer by causing polymer swelling and reduction of the frictional forces between the polymer chains consequently decreasing the mechanical properties of the cured polymer [39, 40].
However, one cannot deny that the vigorous application mode was not capable to completely prevent the degradation of the dentin bonding interface, as some restorations were lost throughout the study period. Although this technique seems to improve the resin impregnation into the demineralized collagen network, it cannot alter the nature of the adhesive, which continues to be intrinsically hydrophilic and therefore still prone to water sorption [6, 41]. Besides that, the vigorous application mode does not inactivate endogenous collagenolytic and gelatinolytic activities derived from acid-etched dentin, which is thought to be responsible for the progressive disintegration of the fibrillar collagen network [12, 13, 42, 43].
Marginal staining is thought to be one of the first clinical signs that a resin composite restoration is prone to failure. Marginal discoloration may be caused by the presence of excess or deficit filling materials at the margin, the formation of gaps [44, 45], and also by retention of microscopic pigments derived from colored beverages and food in the adhesive layer. This discoloration occurred at the enamel margins for the majority of the restorations, which seems to be a common finding in clinical studies [37, 39, 45–48]. It is likely that an over-etching of the enamel in the buccal surfaces would reduce the marginal discoloration observed in this study. The vigorous rubbing group showed less marginal discoloration than the other two application modes owing to the better quality of the polymer network as addressed earlier in this “Discussion” section. It is worth to point out, however, that marginal discoloration does not seem to jeopardize the longevity of the restoration to any significant level as it does not necessarily mean defective restorations. Most of the marginal staining observed in this study appeared to be superficial and could be easily removed by a new finishing and polishing procedure.
All restorations were scored according to the Cvar and Ryge criteria [19]. Meanwhile, it was addressed that the evaluation of the clinical performance according to Ryge is not precise enough since there are many clinical variables simultaneously involved [49]. They state that, specifically, the clinical evaluation of resin-based restorations requires a more sensitive interpretation, which can easily be compared to other studies, including the habits of patients (such as bruxism) and the existing damage or location and size of the cavity [49]. This was the reason why new criteria were developed and recently published. Unfortunately, the present study was already ongoing by the time the Hickel’s criteria were published [49], which prevented us from employing it.
Conclusion
The use of a vigorous application mode can be a viable clinical approach to improve the retention of restorations placed in non-carious cervical lesions using simplified etch-and-rinse adhesives.
References
Breschi L, Mazzoni A, Ruggeri A, Cadenaro M, Di Lenarda R, De Stefano DE (2008) Dental adhesion review: aging and stability of the bonded interface. Dent Mater 24:90–101. doi:10.1016/j.dental.2007.02.009
De Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M, Van Meerbeek B (2005) A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res 84:118–132
Peumans M, Kanumilli P, De Munck J, Van Landuyt K, Lambrechts P, Van Meerbeek B (2005) Clinical effectiveness of contemporary adhesives: a systematic review of current clinical trials. Dent Mater 21:864–881. doi:10.1016/j.dental.2005.02.003
Nakabayashi N, Pashley DH (1998) Hybridization of dental hard tissue. Quintessence books, Chicago
Tay FR, Pashley DH (2003) Have dentin adhesives become too hydrophilic? J Can Dent Assoc 69:726–731
Malacarne J, Carvalho RM, de Goes MF, Svizero N, Pashley DH, Tay FR, Yiu CF, Carrilho MR (2006) Water sorption/solubility of dental adhesive resins. Dent Mater 22:973–980. doi:10.1016/j.dental.2005.11.020
Cardoso PC, Loguercio AD, Vieira LC, Baratieri LN, Reis A (2005) Effect of prolonged application times on resin–dentin bond strengths. J Adhes Dent 7:143–149
Reis A, de Carvalho CP, Vieira LC, Baratieri LN, Grande RH, Loguercio AD (2008) Effect of prolonged application times on the durability of resin–dentin bonds. Dent Mater 24:639–644. doi:10.1016/j.dental.2007.06.027
Klein-Júnior CA, Zander-Grande C, Amaral R, Stanislawczuk R, Garcia EJ, Baumhardt-Neto R, Meier MM, Loguercio AD, Reis A (2008) Evaporating solvents with a warm air-stream: effects on adhesive layer properties and resin–dentin bond strengths. J Dent 36:618–625. doi:10.1016/j.jdent.2008.04.014
Breschi L, Mazzoni A, Pashley DH, Pasquantonio G, Ruggeri A, Suppa P, Mazzotti G, Di Lenarda R, Tay FR (2006) Electric-current-assisted application of self-etch adhesives to dentin. J Dent Res 85:1092–1096
Pasquantonio G, Tay FR, Mazzoni A, Suppa P, Ruggeri A Jr, Falconi M, Di Lenarda R, Breschi L (2007) Electric device improves bonds of simplified etch-and-rinse adhesives. Dent Mater 23:513–518. doi:10.1016/j.dental.2006.03.009
Carrilho MR, Geraldeli S, Tay F, de Goes MF, Carvalho RM, Tjäderhane L, Reis AF, Hebling J, Mazzoni A, Breschi L, Pashley D (2007) In vivo preservation of the hybrid layer by chlorhexidine. J Dent Res 86:529–533
Hebling J, Pashley DH, Tjäderhane L, Tay FR (2005) Chlorhexidine arrests subclinical degradation of dentin hybrid layers in vivo. J Dent Res 84:741–746
Stanislawczuk R, Amaral RC, Zander-Grande C, Gagler D, Reis A, Loguercio AD (2009) Chlorhexedine-containing acid conditioner preserves the longevity of resin–dentin bonds. Oper Dent 34:483–492. doi:10.2341/08-016-L
Al-Ammar A, Drummond JL, Bedran-Russo AK (2009) The use of collagen cross-linking agents to enhance dentin bond strength. J Biomed Mater Res B Appl Biomater In press
Dal-Bianco K, Pellizzaro A, Patzlaft R, de Oliveira Bauer JR, Loguercio AD, Reis A (2006) Effects of moisture degree and rubbing action on the immediate resin–dentin bond strength. Dent Mater 22:1150–1156. doi:10.1016/j.dental.2005.10.010
Reis A, Pellizzaro A, Dal-Bianco K, Gones OM, Patzlaff R, Loguercio AD (2007) Impact of adhesive application to wet and dry dentin on long-term resin–dentin bond strengths. Oper Dent 32:380–387. doi:10.2341/06-107
Swift EJ Jr, Perdigão J, Wilder AD Jr, Heymann HO, Sturdevant JR, Bayne SC (2001) Clinical evaluation of two one-bottle dentin adhesives at three years. J Am Dent Assoc 132:1117–1123
Cvar JF, Ryge G (2005) Reprint of criteria for the clinical evaluation of dental restorative materials. Clin Oral Invest 9:215–232. doi:10.1007/s00784-005-0018-z
American Dental Association (2001) Council on scientific affairs American Dental Association program guidelines: products for dentin and enamel adhesive materials (www.ada.org). American Dental Association, Chicago
Perdigão J, Carmo AR, Geraldeli S (2005) Eighteen-month clinical evaluation of two dentin adhesives applied on dry vs moist dentin. J Adhes Dent 7:253–258
Türkün SL (2003) Clinical evaluation of a self-etching and a one-bottle adhesive system at two years. J Dent 31:527–534
Pocock SJ (1983) The size of a clinical trial. In: Pocock SJ (ed) Clinical trials: a practical approach. Wiley, Chinchester, pp 123–141
Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M, Vijay P, Van Landuyt K, Lambrechts P, Vanherle G (2003) Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. Oper Dent 28:215–235
Miyasaki M, Onose H, Moore BK (2002) Analysis of the dentin–resin interface by use of laser Raman spectroscopy. Dent Mater 18:576–580
Wang Y, Spencer P (2003) Hybridization efficiency of the adhesive/dentin interface with wet bonding. J Dent Res 82:141–145
Sano H, Takatsu T, Ciucchi B, Horner JA, Matthews WG, Pashley DH (1995) Nanoleakage: leakage within the hybrid layer. Oper Dent 20:18–25
Hashimoto M, Ohno H, Kaga M, Sano H, Endo K, Oguchi H (2002) The extent to which resin can infiltrate dentin by acetone-based adhesives. J Dent Res 81:74–78
Demirci M, Sancakli HS, Uysal O (2008) Clinical evaluation of a polyacid-modified resin composite (Dyract) in class V carious lesions: 5-year results. Clin Oral Investig 12:157–163
Federlin M, Thonemann B, Schmalz G, Urlinger T (1998) Clinical evaluation of different adhesive systems for restoring teeth with erosion lesions. Clin Oral Investig 2:58–66
Folwaczny M, Loher C, Mehl A, Kunzelmann KH, Hickel R (2001) Class V lesions restored with four different tooth-colored materials–3-year results. Clin Oral Investig 5:31–39
Kubo S, Yokota H, Yokota H, Hayashi Y (2009) Two-year clinical evaluation of one-step self-etch systems in non-carious cervical lesions. J Dent 37:149–155. doi:10.1016/j.jdent.2005.04.003
Cho B, Dickens SH (2004) Effects of the acetone content of single solution dentin bonding agents on the adhesive layer thickness and the microtensile bond strength. Dent Mater 20:107–115
Loguercio AD, Loeblein F, Cherobin T, Ogliari F, Piva E, Reis A (2009) Effect of solvent removal on adhesive properties of simplified etch-and-rinse systems and on bond strengths to dry and wet dentin. J Adhes Dent 11:213–219
Paul SJ, Leach M, Rueggeberg FA, Pashley DH (1999) Effect of water content on the physical properties of model dentine primer and bonding resins. J Dent 27:209–214
Reis A, Grandi V, Carlotto L, Bortoli G, Patzlaff R, Rodrigues Accorinte M, Dourado Loguercio A (2005) Effect of smear layer thickness and acidity of self-etching solutions on early and long-term bond strength to dentin. J Dent 33:549–559
Takahashi A, Sato Y, Uno S, Pereira PN, Sano H (2002) Effects of mechanical properties of adhesive resins on bond strength to dentin. Dent Mater 18:263–268
Malacarne-Zanon J, Pashley DH, Agee KA, Foulger S, Alves MC, Breschi L, Cadenaro M, Garcia FP, Carrilho MR (2009) Effects of ethanol addition on the water sorption/solubility and percent conversion of comonomers in model dental adhesives. Dent Mater 25(10):1275–84
Kalachandra S, Turner DT (1987) Water sorption of polymethacrylate networks: bis-GMA/TEGDM copolymers. J Biomed Mater Res 21:329–338
Söderholm KJ (1984) Water sorption in a bis(GMA)/TEGDMA resin. J Biomed Mater Res 18:271–279
Yiu CK, King NM, Carrilho MR, Sauro S, Rueggeberg FA, Prati C, Carvalho RM, Pashley DH, Tay FR (2006) Effect of resin hydrophilicity and temperature on water sorption of dental adhesive resins. Biomaterials 27:1695–1703. doi:10.1016/j.biomaterials.2005.09.037
Brackett WW, Tay FR, Brackett MG, Dib A, Sword RJ, Pashley DH (2007) The effect of chlorhexidine on dentin hybrid layers in vivo. Oper Dent 32:107–111. doi:10.2341/06-55
Pashley DH, Tay FR, Yiu C, Hashimoto M, Breschi L, Carvalho RM, Ito S (2004) Collagen degradation by host-derived enzymes during aging. J Dent Res 83:216–221
Neo J, Chew CL, Yap A, Sidhu S (1996) Clinical evaluation of tooth-colored materials in cervical lesions. Am J Dent 9:15–18
Powell LV, Gordon GE, Johnson GH (1991) Clinical evaluation of direct esthetic restorations in cervical abrasion/erosion lesions: one-year results. Quintessence Int 22:687–692
Burrow MF, Tyas MJ (2008) A clinical trial comparing two all-in-one adhesive systems used to restore non-carious cervical lesions: results at one year. Aust Dent J 53:235–238
Jacobsen T, Söderholm KJ (1998) Effect of primer solvent, primer agitation, and dentin dryness on shear bond strength to dentin. Am J Dent 11:225–228
Reis A, Loguercio AD (2009) A 36-months’ evaluation of ethanol/water and acetone-based etch-and-rinse adhesives in non-carious cervical lesions. Oper Dent 34:181–191. doi:10.2341/08-117
Hickel R, Roulet JF, Bayne S, Heintze SD, Mjör IA, Peters M, Rousson V, Randall R, Schmalz G, Tyas M, Vanherle G (2007) Recommendations for conducting controlled clinical studies of dental restorative materials. Clin Oral Investig 11:5–33. doi:10.1007/s00784-006-0095-7
Acknowledgments
This study was partially supported by the National Council for Scientific and Technological Development (CNPq) under grants 305075/2006-3 and 303933/2007-0.
Conflict of interest
The authors of this study declare they do not have proprietary, financial, professional, or other personal interest of any nature or kind in the products and/or companies that could be construed as influencing the position presented in this manuscript.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Loguercio, A.D., Raffo, J., Bassani, F. et al. 24-month clinical evaluation in non-carious cervical lesions of a two-step etch-and-rinse adhesive applied using a rubbing motion. Clin Oral Invest 15, 589–596 (2011). https://doi.org/10.1007/s00784-010-0408-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00784-010-0408-8