Abstract
Background
Although there has been continuous evolution in the management of fracture fixation, treatment for osteoporotic proximal humerus fractures is still challenging to trauma surgeons. The purpose of this study was to report early failure of the locking compression plate (LCP) in the treatment of osteoporotic proximal humerus fracture and characterize the mode of failure.
Methods
Nine patients, older than 65 years, underwent internal fixation with the use of a locking compression plate and had early failure within 4 weeks postoperatively. According to Neer’s classification, five were included in a two-part surgical neck fracture, three in a three-part fracture, and one in a four-part fracture.
Results
All failures occurred with back-out of the plate—screw construct, leading to varus displacement in eight patients and plate breakage in one. Revision surgery was performed in six patients using replating and tension band wiring with a bone graft, and three patients underwent hemiarthroplasty. The average UCLA score was 25 points for the hemiarthroplasty group and 30 points for the reconstruction group.
Conclusions
Early postoperative failure of the LCP developed within 4 weeks with a presentation of en bloc back-out of the plate-screw construct and plate breakage. Possible risk factors included malreduction, loss of medial support, and negligence of tension band sutures on the tuberosities.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Instrum K, Fennell C, Shrive N, Damson E, Sonnabend D, Hollinshead R. Semitubular blade plate fixation in proximal humeral fractures: a biomechanical study in a cadaveric model. J Shoulder Elbow Surg 1998;7:462–466.
Palvanen M, Kannus P, Niemi S, Parkkari J. Update in the epidemiology of proximal humeral fractures. Clin Orthop 2006;442:87–92.
Spence RJ. Fractures of the proximal humerus. Curr Opin Orthop 2003;14:269–280.
Bjorkenheim JM, Pajarinen J, Savolainen V. Internal fixation of proximal fractures with a locking compression plate. Acta Orthop Scand 2004;75:741–745.
Iannotti JP, Ramsey ML, Williams GR, Warner JP. Nonprosthetic management of proximal humeral fractures. J Bone Joint Surg Am 2003;85:1578–1593.
Court-Brown CM, Garg A, McQueen MM. The translated twopart fracture of the proximal humerus: epidemiology and outcome in the older patient. J Bone Joint Surg Br 2001;83:799–804.
Smith AM, Mardones RM, Sperling JW, Cofield RH. Early complications of operatively treated proximal humeral fractures. J Shoulder Elbow Surg 2007;16:14–24.
Herscovici D Jr, Saunders DT, Johnson MP, Sanders R, DiPasquale T. Percutaneous fixation of proximal humeral fractures. Clin Orthop 2000;375:97–104.
Agel J, Jones CB, Sanzone AG, Camuso M, Henley MB. Treatment of proximal humeral fractures with Polarus nail fixation. J Shoulder Elbow Surg 2004;13:191–192.
Hintermann B, Trouillier HH, Schafer D. Rigid internal fixation of fracture of the proximal humerus in older patients. J Bone Joint Surg Br 2000;82:1107–1112.
Kawashima T, Uhthoff HK. Pattern of bone loss the proximal femur: a radiologic, densitometric, and histomorphometric study. J Orthop Res 1991;9:634–640.
Mosekilde L. Age-related changes in bone mass, structure, and strength: effect of loading. Z Rheumatol 2000;59:1–9.
Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R. A new locking plate for unstable fractures of the proximal humerus. Clin Orthop 2005;430:176–181.
Strohm PC, Kostler W, Sudkamp NP. Locking plate fixation of proximal humerus fractures. Tech Shoulder Elbow Surg 2005;6:8–13.
Wagner M. General principles for the clinical use of the LCP. Injury 2003;34(suppl 2):B31–B42.
Sommer C, Babst R, Muller M, Hanson B. Locking compression plate loosening and plate breakage: a report of four cases. J Orthop Trauma 2004;18:571–577.
Ellman H, Hanker G, Bayer M. Repair of the rotator cuff: end-result study of factors influencing reconstruction. J Bone Joint Surg Am 1986;68:1136–1144.
Neer CS. 2nd Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am 1970;52:1077–1089.
Maldonado ZM, Seebeck J, Heller MO, Brandt D, Hepp P, Lill H, et al. Straining of the intact and fractured proximal humerus under physiological-like loading. J Biomech 2003;36:1865–1873.
Chudik SC, Weinhold P, Dahners LE. Fixed angle plate fixation in simulated fractures of the proximal humerus: a biomechanical study of a new device. J Shoulder Elbow Surg 2003;12:578–588.
Liew AS, Johnson JA, Patterson SD, King GJ, Chess DG. Effect of screw placement on fixation in the humeral head. J Shoulder Elbow Surg 2000;9:423–426.
Hepp P, Lill H, Bail H, Korner J, Niederhagen M, Haas NP, et al. Where should implants be anchored in the humeral head? Clin Orthop 2003;415:139–147.
Lill H, Hepp P, Korner J, Kassi J, Verheyden AP, Josten C, et al. Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg 2003;123:74–81.
Kaab MJ, Frenk A, Schmeling A, Schaser K, Schutz M, Haas NP. Locked internal fixator: sensitivity of screw/plate stability th the correct insertion angle of the screw. J Orthop Trauma 2004;18:483–487.
Author information
Authors and Affiliations
About this article
Cite this article
Micic, I.D., Kim, KC., Shin, DJ. et al. Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures. J Orthop Sci 14, 596–601 (2009). https://doi.org/10.1007/s00776-009-1382-3
Received: