Abstract
The relevant low-frequency modes of plan-asymmetric tall buildings and those of bridges consist of coupled translational and torsional motions. We consider the locations of the modal centers of velocity of either the rigidly assumed floors or of the bridge cross-sections to be crucial for selecting the design and the “optimal” position of the liquid absorbers. Such a tuned liquid column-gas damper, TLCGD consists of a sealed rigid piping system that is partially filled with liquid (preferably water), whose dynamics can be derived using the nonstationary Bernoulli equation properly extended to account for the relative streamline in a moving reference system. Although both the construction and working principle of TLCGDs differ from tuned mass dampers (TMD), a geometric analogy exists between these absorber types. Consequently, in a first step modal tuning is performed by means of a transformation of the TMD optimal parameters, e.g., of the Den Hartog formulas, possibly followed in a second step by fine-tuning in state-space. Such a U- or V-shaped sealed liquid column-gas damper, i.e., with the gas-spring effect taken into account, is found suitable for applications in moderately plan-asymmetric buildings (the floors’ modal center of velocity falls outside of the floor plan) and for bridges with dominant horizontal vibrations. The novel design of a torsional sealed liquid column-gas damper, TTLCGD, turns out to have even higher efficiency in effectively damping strongly asymmetric buildings, where the floors’ modal centers of velocity lie inside of the floor plan: in that case of an alternative design, the mid-plane of the U-shaped TLCGD is bent to a cylindrical surface that might be “nearly closed” such that the trace in the floor becomes approximately a loop. For bridges with dominating vertical flexural vibrations, a novel pipe-in-pipe design of the VTLCGD provides the vertical control force rendering the additional efficient damping. The evident features of TLCGDs are no moving mechanical parts, cheap and easy implementation into civil engineering structures, simple modification of the natural frequency and even of the damping properties, low maintenance costs, little additional weight in those cases where a water reservoir is required, e.g., for the sake of fire fighting, and with a performance comparable to that of TMDs of the spring-mass- (or pendulum-)-dashpot type.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Petersen, Ch.: Schwingungsdämpfer im Ingenieurbau. Munich: Maurer S. 2001. ISBN 3-00-008059-7
Hochrainer, M.J.: Control of vibrations of civil engineering structures with special emphasis on tall buildings. Vienna University of Technology, Austria. http://www.tuwien.ac.at/. Dissertation 2001
Hochrainer M.J.: Tuned liquid column damper for structural control. Acta Mech. 175, 57–76 (2005)
Hochrainer M.J., Ziegler F.: Control of tall building vibrations by sealed tuned liquid column dampers. J. Struct. Control Health Monit. 13(6), 980–1002 (2006)
Reiterer, M.: Damping of vibrational civil engineering structures with emphasis on bridges. Vienna University of Technology, Austria. http://www.tuwien.ac.at/. Dissertation, 2004
Reiterer M., Ziegler F.: Control of pedestrian-induced vibrations of long-span bridges. J. Struct. Control Health Monit. 13(6), 1003–1027 (2006)
Reiterer M., Ziegler F.: Bi-axial seismic activation of civil engineering structures equipped with tuned liquid column dampers. J Seismol. Earthq. Eng. (JSEE) 6(3), 45–60 (2004)
Fu, Chuan: Vibration control for asymmetric buildings. Vienna University of Technology, Austria. http://www.tuwien.ac.at/. Dissertation 2008
Ziegler, F., Fu, Chuan: Effective vibration damping of plan-asymmetric buildings. In: Sabouni, A.-R.R., El-Sawy, K.M. (eds.) The 8th Int. Conf. on Multi-Purpose High-rise Towers and Tall Buildings. The International Federation of High-Rise Structures, CD-ROM Paper ID IFHS-039. Abu Dhabi: 2007 (Download: http://www.acevents.ae “online documents” ifhs2007+ifhs2007dxb _TB-28.pdf) pp. 1–13
Reiterer, M., Ziegler, F.: Flüssigkeitstilger zur Tilgung von Schwingungen für Bauwerke. Patentschrift AT 501 870 B1, 2005-08-15, Österreichisches Patentamt. Patentanmelder: Vienna University of Technology, Austria, pp. 1–14
Ziegler F.: Der Flüssigkeitstilger dämpft Schwingungen im Hoch- und Brückenbau. Bauingenieur 81, 259–270 (2006)
Lindner-Silvester T., Schneider W.: The moving contact line with weak viscosity effects – an application and evaluation of Shikhmurzaev’s model. Acta Mech. 176, 245–258 (2005)
Lindner-Silvester, T.: Die bewegte Kontaktlinie mit schwachen Reibungseffekten. Vienna University of Technology, Austria. http://www.tuwien.ac.at/. Dissertation 2003
Zunzer, J.: Experimentelle und numerische Untersuchungen zur bewegten Kontaktlinie. Vienna University of Technology, Austria. http://www.tuwien.ac.at/. Dissertation 2002
Den Hartog J.P.: Mechanical Vibrations Repr., 4th edn. McGraw-Hill, New York (1956)
Gao H., Kwok K.S.C., Samali B.: Characteristics of multiple tuned liquid column dampers in suppressing structural vibration. Eng. Struct. 21, 316–331 (1999)
Adam C., Hruska A., Kofler M.: Elastic Structures with tuned liquid column dampers. In: Durakbasa, M.N., Afjehi, A., Osanna, P.H.(eds) The XVI IMEKO WORLD CONGRESS, vol. VII, pp. 351–356. Intern. Measurement Confederation, Vienna (2000)
Chang C.C., Hsu C.T.: Control performance of liquid column vibration absorbers. Eng. Struct. 20, 580–586 (1998)
Shum K.M., Xu Y.L.: Multiple-tuned liquid column dampers for torsional vibration control of structures: experimental investigation. Earthq. Eng. Struct. Dyn. 31, 977–991 (2002)
Teramura, A., Yoshida, O.: Development of vibration control system using U-shaped water tank. In: 11th World Congress of Earthquake Engineering (WCEE, Sociedad Mexicana de Ingenieria Sismica, A.C.), paper ID-no. 1343. Elsevier Science Ltd (1996)
Huo L.S., Li H.N.: Torsionally coupled response control of offshore platform structures using circular tuned liquid column dampers. China Ocean Eng. 18(2), 173–183 (2004)
Colwell, S., Base, B.: Tuned liquid column dampers in offshore wind turbines for structural control. Eng. Struct. (2008, in press)
Ziegler F.: Mechanics of Solids and Fluids. Corr. Repr., 2nd edn. Springer, New York (1998)
Soong T.T, Dargush G.F.: Passive Energy Dissipation Systems in Structural Engineering. Wiley, Chichester (1997)
Warburton G.B.: Optimum absorber parameters for various combinations of response and excitation parameters. Earthq. Eng. Struct. Dyn. 10, 381–401 (1982)
MATLAB: User Guide, Control Toolbox. Version 6.5.1. MathWorks Inc. (2002)
Nowacki W.: Baudynamik, Transl. 2nd Polish edn, (in German). Springer, Wien (1974)
Achs, G.: Anwendung von Flüssigkeitstilgern bei Schrägseilbrücken im Freivorbauzustand unter Windanregung. Diplomarbeit. Master Thesis, Vienna University of Technology, Austria. http://www.tuwien.ac.at/. Report: E206/3-No.1 (2005)
Sun, L.M., Nakaoka, I.: Tuned liquid damper for suppressing vertical vibrations. In: 45th JSCE Annual Meeting, vol. 1, pp. 978–979 (1990)
Ziegler F.: The tuned liquid column damper as the cost-effective alternative of the mechanical damper in civil engineering structures. Int. J. Acoust. Vib. 12(1), 25–39 (2007)
Author information
Authors and Affiliations
Corresponding author
Additional information
Dedicated to Professor Wilhelm Schneider on the occasion of his 70th birthday
Rights and permissions
About this article
Cite this article
Ziegler, F. Special design of tuned liquid column-gas dampers for the control of spatial structural vibrations. Acta Mech 201, 249–267 (2008). https://doi.org/10.1007/s00707-008-0062-2
Received:
Published:
Issue Date: