Introduction

Chlorpyrifos is one of the many organophosphate pesticides (OPPs). According to previous reports, exposure to chlorpyrifos (CPS) can lead to change of polyamine metabolism and induce oxidative stress and can also cause DNA damage [1]. Chlorpyrifos is considered extremely toxic because when it enters food, it has detrimental effect on humans and animals [2]. Therefore, monitoring the behavior of CPS residues is important for human health. Significant efforts have been devoted to developing direct techniques for the determination of pesticides [3,4,5,6,7,8,9,10] Among these methods, electrochemical aptasensors play an important role and this is due to their high sensitivity, excellent specificity, convenience, easily detectable signals and simplicity; thus, decreasing the analysis time and cost [11].

Aptamers are synthetic single-stranded functional DNA or RNA molecules which are selected from random oligonucleotide libraries by an in vitro evolution process named SELEX (systemati evolution of ligands by exponential enrichment) [12]. Aptamers were replaced by antibodies as diagnostic elements in bioavailability because of the ease of producing, more stability, easy labeling and lower cost. Due to these, aptamer-based assay were established using various detection methods [13,14,15]. Among these methods, electrochemical aptasensors play an important role for their excellent specificity, high sensitivity, easily detectable signals, and simplicity and is easily modified for their detection and immobilization by the introduction of reporter molecules and functional groups [16, 17].

Metal nanoparticles with different nanostructures including rings, spheres, rods and cages have been used in various applications [18,19,20,21,22]. Among them, the subtle behavior of gold nanorods (AuNR) revealed that they have the ability to promote faster electron transfer and distinct optical properties depended on their shape and thus, electron transfer between electrode and analytes reactions in electrochemical reactions [22]. Therefore, to further enhance the amount of effective binding sites in the assay and supply larger electrochemically active surface areas, the aptasensor was decorated with nanoparticles such as AuNR [23].

Molecularly imprinted polymer receptors (MIPs), as novel materials and biomimetic molecular recognition elements have been widely applied in various fields [24,25,26]; this is due to the presence of such unique properties as desired selectivity, superb physical and chemical stability, commercial availability as well as low cost, compared to those of enzymes, antibodies and receptors [27]. Usually, typical MIPs include template molecules, functional monomers, cross-linking reagents; which nowadays, MIP films are most commonly polymerized by sol-gels, bulk polymerization and precipitation polymerization. Behind the polymerization, the template molecules are removed from the final polymer matrixes [28,29,30]. These methods often have limitations such as partial template removal, slow mass transfer and rebinding kinetics in sensor applications [31]. Therefore, the electrochemical polymerization was suggested because it is one of the efficient ways of solving these limitations by generating a rigid, uniformed compact MIP film with controlled thickness onto the work electrode surface of any shape and size [32, 33].

The aim of this study was to develop a highly sensitive electrochemical aptasensor based on electro polymerized MIP and AuNR for the determination of CPS. The exploitation of gold nanorods improved the electron transfer rate and provided a high surface area for immobilization of the MIP-aptamer. The fabricated MIP-aptasensor shows excellent selectivity, sensitivity, as well as satisfactory results for the detection of CPS in real samples.

Experimental

Materials and reagents

The amino modified aptamer against CPS was purchased from Bioneer Co, (South Korea, http://www.bioneer.com). The sequence of nucleotides in the aptamer is shown below; the sequence contained 91 bases. (5′-NH2 modified) (5′-CCTGCCACGCTCCGCAAGCTTAGGGTTACGCCTGCAGCGATTCTTGATCGCGCTGCTGGTAATCCTTCTTTAAGCTTGGCACCCGCATCGT-3′). They had been HPLC-purified and freeze-dried by the supplier and was kept for further use. Cetyltrimethyl ammonium bromide (CTAB), Sodium borohydride (NaBH4), Tetra chloroauric acid (HAuCl4), Silver nitrate (AgNO3), o-Dihydroxybenzene (o-DB), o-phenylenediamine (o-PD) and CPS were received from Sigma–Aldrich Co. (https://www.sigmaaldrich.com), LLC (USA) (www.usa-corporate.com) or Merck (www.merck.com) companies.

Apparatus

All electrochemical experimental data including differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV) data, were carry out with μ-AUTOLAB electrochemical system type III and FRA2 board computer controlled Potentiostat/Galvanostat (Eco-Chemie, Switzerland) driven with NOVA software in conjunction with a conventional three electrode system and in 5 mM Fe(CN)63−/4- solution. The working electrode was a modified GCE, and the auxiliary and reference electrodes were a platinum wire and an Ag/AgCl (satd 3.0 M KCl), respectively. The impedance analysis was performed in a frequency range between 0.1 Hz and 100 kHz with a modulation voltage of 5 mV. Cyclic voltammetry measurements were taken from −0.2 to 0.7 V as initial and stop potential. The DPV measurements were carried out by scanning the potential of −0.2 to 0.7 V with modulation time of 50 ms and modulation amplitude of 25 mV. Scanning electron microscopy (SEM) images were obtained by using FESEM apparatus (Model: Hitachi S4160). Transmission electron microscopy (TEM) image was recorded by a Hitachi H-800 electron microscope. The absorption measurement was investigated using an ultraviolet-visible (UV–Vis) spectrophotometer (VARIAN 300Bio CARY) in dual beam mode with a 1 cm quartz cuvette.

Synthesis of the gold nanorods (AuNR)

The AuNR was synthesized by making reference to reported methods in previous literatures and by making some modifications to them [20]. This section is presented in Electronic Supplementary Material.

Preparation of aptamer-MIP

The aptamer-MIP was synthesized by referring to the reported methods in previous literatures [34, 35]. Aptamer-MIP solution was prepared in the following procedure: first, 0.1 mM CPS was added to 0.05 M phosphate buffer (pH = 7.6) containing 1 μM of the aptamer to form the CPS–aptamer complex and stirred for 5 min. Then, 0.01 g of o-Dihydroxybenzene (o-DB) and 0.01 g of o-phenylenediamine (o-PD) were dissolved in 6 mL of 0.05 M Tris-HCl buffer (pH = 8.0) and afterwards 4 mL of the CPS–aptamer complex (prepared above) was added and mixed for 5 min. Subsequently, non-imprinted polymer (NIP) modified electrode were prepared analogous to the MIP without adding CPS (template).

Fabrication of MIP-aptasensor

The fabrication process for the electrochemical aptasensor is shown in Scheme 1 and the procedure is described thus: the GCE was polished carefully with alumina powder (0.05 μm) on a soft polishing cloth; and then rinsed thoroughly with ultrapure distilled water and dried before use. Thereafter, 10 μL of synthesized AuNR solution was dropped onto the surface of the freshly polished GCE and dried at room temperature. In the following, the obtained AuNR/GCE was immersed in a solution containing polymerization solution (aptamer-MIP prepared in section preparation of aptamer-MIP). By applying a potential range between 0 to 1.0 V for 10 cycles, with scan rate of 50 mVs−1, the aptamer-MIP was electropolymerized on the AuNR/GCE surface and the aptamer-MIP/AuNP/GCE as the aptasensor was achieved. Then, the washing solution containing methanol–nitric acid (4:1, v/v) was used to remove the CPS molecules from the cavities and holes in the MIP on the modified electrode surface. The aptamer-NIP/AuNP/GCE was fabricated by the same method, but without the CPS template.

Scheme 1
scheme 1

Schematic representation of electrochemical MIP-aptasensing assay for CPS detection

Sample preparation

Food samples including apples and lettuce purchased from the supermarket were washed, dried, chopped into 3 × 3 mm particles approximately. 10 g of each sample was sprayed with different concentrations of chlorpyrifos. After equilibration for 3 h at room temperature to make pesticide absorbed into the samples, 10 mL mixed solution of acetone and 0.1 M pH 7.5 phosphate buffer (1/9, v/v) was added to the above samples.. Then the suspension was separated from the insoluble materials by centrifugation for 20 min at 1008 rcf and finally, it was filtered to remove the large particles [36]. The residue was diluted with water and detects the advance assay by standard addition method.

Results and discussion

Choice of materials

Ortho-phenylenediamine (o-PD) and o-dihydroxybenzene (o-DB) was chosen as functional monomer because of several reasons. First, after electropolymerization, the skeleton of MIP film can form groups such as –NH and –OH, these groups can more effective imprinted site [34]. Second, the o-PD layer appears to confer selectivity by limiting access of large molecules to the surface. Thus, biochemicals larger than o-PD cannot penetrate the film. For this reason, we chose to use o-PD to make selective CPS assay. Also, the amino group and benzene ring can provide recognition sites through hydrogen bonds and “п-п stacking” interaction with analyzing CPS. The o-PD proved to be easily electropolymerized on various substrate materials and form films with good chemical and mechanical stability. O-Dihydroxybenzene have been used as electron transfer mediators in electrochemical processes due to their high electron transfer efficiency, excellent redox reversibility and low cost. AuNR based platforms can provide more stable biosensing systems due to their rods-like shapes compared to nanoparticles. Besides, the modification of the electrodes using AuNR can facilitate a higher conductive surface by providing an enhanced electron transfer, and thus they offer the enhanced modified electrode response with in a high sensitivity. Compared with similarly sized spherical nanoparticles, AuNR exhibit higher absorption cross section in near-infrared (NIR) frequencies. The characteristic surface plasmon band of colloidal gold nanoparticles is observed in the visible range; however, AuNR have a surface plasmon band in the near-infrared region with a coexisting weaker band in the visible region. Moreover, the experimental protocols used in the synthesis of AuNR allow tuning their surface plasmon resonance into the biological window of the electromagnetic spectrum [37,38,39,40,41,42]. The designed nanotools based of aptamer-MIP [PmDB-PoPD] and AuNR had many advantages, such as good mechanical and chemical stability, low–cost, high sensitivity, excellent selectivity, simple, and possibility of in–situ testing.

Characterization of synthesized gold nanorods

This section is presented in Electronic Supplementary Material.

Characterization of the modified electrode

To evaluate the morphologies and surface of the different modified electrodes, the SEM technique was used. Fig. 1 shows the SEM images of the bare GC (A), AuNR/GC (B) and aptamer-MIP/AuNR/GC electrodes. After the AuNR on the surface of the bare electrode which shows the uniform surface was immobilized (Fig. 1a), the structures of the rod corresponding to AuNR (Fig. 1b) can be clearly observed. In the next step, after electro polymerization, the complex MIP and aptamer and the formation of the aptamer-MIP film on the surface of AuNR/GCE (Fig. 1c), the surface morphology was changed and became uneven and rough. The results also showed that MIP linked to the surface of AuNR further expands the surface area on the modified electrode for more recognition of CPS. It was speculated that the AuNR possibly form N-Au bonding with the inner surface of o-PD molecules, which in turn results in the dense layer of NIP multilayer nanofilms, in the absence of CPS molecule (Fig. 1d).

Fig. 1
figure 1

SEM images related to bare GCE (A), AuNR/GCE (B) and MIP-aptamer/AuNR/GCE (C) and NIP-aptamer/AuNR/GCE (D)

Electrochemical characterization of the designed MIP-aptasensor

EIS is a favored technique to investigate the surface features of the modified electrodes at each immobilization step. According to this technique, the information was obtained about the charge transfer resistance (Rct). Fig. 2a shows the Nyquist plots of impedance spectroscopy of bare GCE (a), AuNR/GCE (b), MIP-aptamer/AuNR/GCE before (c) and after (d) extraction of CPS and modified GCE after immersing in 0.1 pM CPS solution (e) in anion redox probe solution (Fe(CN)63−/4-). From the results, it can be observed that black curve (Fig. 2a, curve a) shows a small semicircle (Rct = 406.0 Ω), which was a characteristic feature of the diffusion controlled electrochemical processes. With the addition of the 10 μL of AuNR to the surface, GCE bear (Fig. 2a, curve b) obviously reduced the resistance of the redox probe (Rct = 186.0 Ω), for a better electric conducting performance of AuNR. In the next stage, by electropolymerization of the PoDB/PoPD and the CPS–aptamer complex onto the AuNR/GCE surface, increase in the semi-circular diameter (Rct = 18.07 KΩ) revealed that the aptamer-MIP film impeded the transfer of electrons and reduced the electron transfer rate (Fig. 2a, curve c). This can be due to the interaction between the –NH2 group of Apt and AuNR. Afterwards, the resistance of the modified electrode decreased with the removal of CPS from the MIP (Fig. 2a, curve d); but since the CPS molecule can matched with MIP cavity, it was enhanced again with the re-adsorption of CPS onto the MIP (Fig. 2a, curve e).

Fig. 2
figure 2

(A) Nyquist curves and (B) CVs of 5 mM [Fe(CN)6] 3−/4- in 0.5 mM KCl recorded for bare GCE (a), AuNR/GCE (b), aptamer-MIP/AuNR/GCE before (c) and after (d) extraction of CPS and aptamer-MIP/AuNR/GCE after immersing in 0.1 pM CPS solution (e). The EIS was performed in a frequency range between 0.1 Hz and 100 kHz with a modulation voltage of 5 mV

Apart from the ESI technique, the fabricated MIP-aptasensor which was used to validate the immobilization of the substrates in each step was characterized by cyclic voltammetry in 5 mM Fe (CN)63−/4-solution. Fig. 2b indicates the cyclic voltammograms of the different steps of modification processes. The CVs displayed the bare GCE (Fig. 2b, curve a). When the AuNR was pipetted on the bare GCE surface, a height current appeared which was attributed to the significant enhancement of the effective surface area of the electrode in the presence of AuNR resulting in facilitating the electron-transfer rate. In the following, a very small current illustrating the successful electropolymerization of the immobilized PoDB/PoPD and the CPS–aptamer complex onto the surface of the AuNR/GCE indicated that the level was completely blocked. However, after the removal of CPS from the MIP, the blockade receded, and the current response was enhanced again (Fig. 2b, curve d). In the next stage, the MIP-aptasensor was once more immersed in the 0.1 pM CPS solution and the blockade was strengthened again. This led to the current decrease in the redox via the CPS adsorbed to the copolymer. The results above are in accordance with the characterization by ESI.

Molecular imprinted electropolymerization

In order to confirm the process of electropolymerization MIP-aptasensor on the surface of AuNR/GC electrode, this parameter was investigated by recording of related CV. As shown in Fig. S2 that the PoDB/PoPD and the CPS–aptamer complex were formed via gradually depositing the non-conducting film onto the AuNR/GCE surface with an increasing number of CV scans. Formation the PoDB/PoPD and the CPS–aptamer complex onto the AuNR/GCE surface obstruct the electron transfer from/to the redox probe [Fe(CN)6]3−/4-. Presence the sharp oxidation peak and equable oxidation peak in the potential of 0.43 V and 0.7 V, respectively, show the oxidation peak might be assigned to the easily oxidative amine group and hydroxyl group of the monomers and electrochemical polymerization of o-PD and o-DB was irreversible. Finally, in the potential range of 0–1.0 V, the chemical structure doesn’t change with the process of electropolymerization.

Optimization of method

To obtain excellent analytical efficiency of the prepared MIP-aptasensor, optimization of the elution time and incubation time parameters was done by the CV method. Respective data and Figures are given in the Electronic Supporting Material Thus, 25 min was chosen as the optimal time for CPS removal (Fig. S3) and 9 min was chosen as the optimal time for incubation of CPS (Fig. S4) and applied to all further experiments.

Analytical performance of the MIP-aptasensors

Under optimal working conditions (desorption time: 25 min and incubation time: 9 min), the MIP-aptasensor was used for the sensitive detection of CPS. Fig. 3a displays the DPV calibration plot of the designed aptasensor using 9 different CPS (0.001 to 0.4 pM) standards in 5 mM [Fe‌(CN)6]3−/4− solution. The results from these analyses demonstrated that the DPV response of the aptasensor diminished with enhancement of the CPS concentration and gave two linear ranges from 0.001–0.03 pM and 0.03–0.4 pM. Furthermore, the linear regression fit was ΔI (μA) = 486.24 [CPS] (pM) + 7.76 (R2 = 0.98) and ΔI (μA) = 25.03 [CPS (pM) + 21.935 (R2 = 0.98). The detection limit (LOD) based on S/N = 3 was calculated to be 0.35 fM and the value of the LOD is lower than that of other reported methods in the literature (Table 1).

Fig. 3
figure 3

(A) DPV responses of the aptasensor in 5 mM [Fe(CN)6]3−/4- after incubation with 0.001, 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.3, and 0.4 pM of CPS. Inset is the calibration plot of peak current vs. CPS concentration The DPV measurements are performed from −0.2 to 0.7 V, with incubation time 9 min, amplitude of 50 mV and a pulse width of 50 ms.

Table 1 Comparison of analytical methods for the detection of CPS

Selectivity, reproducibility and stability of the aptasensor

The selectivity of molecularly imprinted aptasensor was investigated by interferents which included structurally similar molecules and similar property with CPS by higher concentrations than that of CPS. This case was studied by identifying the current response, when the aptasensor was immersed in the 100.0 nM of each interfering substance such as Asulam, Aflatoxin-B1, Dimethoat, Acetamiprid, Carbofuran and Malathion. The results are illustrated in Fig. 4.

Fig. 4
figure 4

Histogram of the DPV response change related to the designed nanotools after being incubated with pesticides compound: 1) Asulam, 2) Aflatoxin-B1, 3) Dimethoat, 4) Acetamiprid, 5) Carbofuran, 6) Malathion (100 nM) and CPS (1 pM)

Also, the reproducibility of the prepared aptasensor was evaluated with the use of five aptasensors into a 5 mM [Fe(CN)6]3−/4- solution. All the modified electrodes exhibited similar electrochemical responses and the RSD = 3.1%, indicating a good reproducibility of the explained strategy.

The repeatability of the designed strategy was estimated into a 5 mM [Fe(CN)6]3−/4- solution by analyzing a certain amount of CPS by five aptasensors, for 18 days. It was observed that about 97.9% and 92.3% of the initial response of the nanotool for CPS remained after being stored at 4 °C for 5 days and 18 days, respectively. The obtained data illustrated the relatively high repeatability of this electrochemical nanotool.

Analysis of real samples

The analytical effectiveness of this strategy for the real quantification of CPS was assayed through the analysis of fruit and vegetable samples. The determinations were performed using a standard addition method and analyzed using independently prepared aptasensors. As shown in Table 2, the determined values were in good agreement with the added pesticide concentrations and indicated the excellent reliability the biosensor for the detection of CPS in real samples.

Table 2 The resultant data for CPS detection in real samples with this electrochemical nanotool (n = 4)

The promising results obtained with aptamer/MIP-based electrochemical assay for the detection of analyte in complex matrices have some advantages such as low cost, easy preparation, high sensitivity and higher selectivity and stability.

Conclusions

In summary, in the present study, a double recognition method for the ultra-selective detection of CPS is reported. Interest of this strategy is combination of aptasensing and molecular imprinting strategies for designing a highly sensitive system to overcome some of the faced challenge by other methods. The AuNR excellent characteristics as sensing interface make this nanoparticle as an attractive matrix for covalently aptamer-MIP immobilization. By following removal of CPS, the double recognition imprinting cavities were formed, indicating recognition properties superior to that of aptamer or traditional molecularly imprinting alone. The analytical usefulness of this nanotool was finally demonstrated by analyzing the real samples. Overlay, it can be easily extended and it has the potential to be applied for detecting other pesticide in food and environmental samples.