Abstract.
An HPLC procedure for determination of phenoxyalkanoic acid herbicides in water samples is proposed. The analytical column Phenomenex C18(2) Luna 5 µm and UV detection at 225 nm were applied. Baseline resolution was achieved in isocratic mode with a mobile phase consisting of acetonitrile/acetic acid (40/60, v/v), adjusted to pH 2.5. SPE sorbents – C18 BondElut, phenyl-silica, LiChrolut SAX and polymeric sorbents – were compared for isolation and preconcentration of 6 phenoxyalkanoic acid herbicides. Higher (above 95%) and more reproducible recoveries were obtained with polymeric and phenyl-silica sorbents using pure methanol for elution. The method was tested for river water samples with the limit of detection in the range of 2–3 µg L−1 (for 50 mL sample) and a reproducibility of 5% RSD.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Biesaga, M., Jankowska, A. & Pyrzyńska, K. Comparison of Different Sorbents for Solid-Phase Extraction of Phenoxyalkanoic Acid Herbicides. Microchim Acta 150, 317–322 (2005). https://doi.org/10.1007/s00604-005-0359-y