Abstract
Objective
The purpose of this study was to evaluate the clinical results of femoral revision using an uncemented extensively porous-coated long femoral stems with or without onlay strut allografts in the treatment of Vancouver type B2 and B3 periprosthetic femoral fractures.
Materials and methods
We retrospectively reviewed 17 cases of periprosthetic femoral fracture (eight B2 and nine B3) treated with the uncemented extensively porous-coated long femoral stem. Clinical outcomes were assessed with Harris Hip Score and Barthel ADL index. Radiological evaluations were conducted using Beals and Towers’ criteria. Any complication during the follow-up period was recorded.
Results
The average follow-up period was 41.7 ± 31.08 (range, 15–132) months. The average Harris Hip Score was 68.2 ± 18.4 (range, 32–100), and the average Barthel ADL index was 80.1 ± 19.75 (range, 30–100) points at the final follow-up. All fractures were united, and a good graft consolidation was achieved in 5 of 9 cases. There was femoral stem subsidence in 4 cases less than 10 mm without an evidence of loosening both radiologically and clinically. The radiological results using Beals and Towers’ criteria were excellent in eight hips, good in five and poor in four.
Conclusions
An uncemented extensively porous-coated long femoral stem together with or without onlay strut allografts provides a good fracture stability that promotes fracture healing and offers a successful solution for the management of Vancouver type B2 and B3 femoral periprosthetic fractures.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Periprosthetic femoral fractures are challenging complication of hip arthroplasty. Although, the incidence of periprosthetic femoral fracture has been reported between 0.4 and 2.1 %, the incidence of periprosthetic femoral fracture is increasing due to the widened indications of joint replacement surgery, increasing average life expectancy and secondary increase of revisions [1]. Although the treatment of such fractures is technically demanding, surgical treatment has become the standard treatment due to high incidence of complications and compromised outcomes with non-operative treatment [2–4]. Duncan and Masri developed a system of classification of periprosthetic femoral fractures according to location, implant stability and residual bone stock (Vancouver Classification) and advocated an algorithm toward surgical treatment [5, 6] (Table 1). The Vancouver classification of periprosthetic femoral fractures is considered a reliable system which has gained the most acceptances, and now, it is commonly used worldwide [7].
Vancouver type B2 and B3 periprosthetic femoral fractures are the most challenging subtypes to manage because of loosened prosthesis and bone stock deficiency. Various surgical techniques and implants have been employed in the management of Vancouver type B2 and B3 periprosthetic femoral fractures in the present literature. However, there is still no consensus with respect to the ideal treatment for these difficult fractures [8]. The purpose of this study was to evaluate the clinical results of femoral revision using an uncemented extensively porous-coated long femoral stems with or without onlay strut allografts in the treatment of Vancouver type B2 and B3 periprosthetic fractures.
Materials and methods
Patients
We retrospectively reviewed a consecutive series of 17 periprosthetic femur fractures that underwent revision total hip arthroplasty (THA) using an uncemented extensively porous-coated distally fixed long femoral stem between February 2000 and December 2009 at our institution. The study was carried out according to the Declaration of Helsinki, and institutional review board approved the study. The fractures were classified according to the Vancouver classification system. Eight hips were classified as Vancouver type B2, and 9 were type B3 based on both preoperative radiographs and operation notes. There were eight men and nine women with an average age of 70.5 ± 10.2 years at the time of operation. In twelve patients, the fracture was caused by minor trauma (fall to the floor), and in one by major trauma (pedestrian traffic accident). In four patients, the fracture occurred spontaneously without a history of apparent traumatic event. The primary diseases were femoral neck fracture in 8 and the primary osteoarthritis in 9 hips. The status of primary arthroplasties was THA in 9 hips (5 cementless femoral stem) and hemiarthroplasty in 8 (1 cementless femoral stem). The average time interval between the periprosthetic fracture and the index operation was 77.2 ± 67.4 months. All patients were contacted either via mail or via telephone and asked to visit our outpatient clinic for the final follow-up. The average follow-up period was 41.7 ± 31.08 (range, 15–132) months. Demographic characteristics are summarized in Table 2.
Surgical technique
An extended posterolateral approach to the hip was performed in all cases. The femoral head was dislocated posteriorly with a bony hook inserted under the neck of the femoral prosthesis. The stems and the remaining cement were removed. An additional osteotomy was needed in three hips for the removal of cement remnants. After exposing a fracture site, the distal extremity of the fracture was identified, and cerclage wire or cable was applied just distal to the fracture to prevent fracture propagation during reaming or true stem impaction. The distal femur was then reamed using sized tapered reamers until a solid torsional grip was obtained to allow the insertion of the revision long stem. Then the femoral stem was inserted, and the fracture was reduced using long stem as an intramedullary nail. In cases whom bone stock and quality was insufficient (Vancouver type B3), cortical onlay strut allograft was used for the augmentation of bone stock. The stability of the acetabulum was checked in cases with previous THAs, and if there is instability, the acetabular component was revised. All bipolar hemiarthroplasty cases were converted to THA. In 12 cases, we have used Echelon Revision Hip System® (Smith and Nephew, Inc, Memphis, TN, USA), and in the remaining five cases, we have used ZMR Hip System® (Zimmer, Warsaw, IN, USA).
Clinical and radiographic evaluations
At the final follow-up, clinical evaluations were performed using Harris Hip Score (HHS) and Barthel activities of daily living (ADL) index [9, 10]. Plain radiographs were examined for evidence of nonunion, loosening and subsidence. Union was defined as bony bridging across an osteotomy site or no migration of the fracture fragment. Subsidence of the stem was measured from the shoulder of the prostheses to the most medial point of the lesser trochanter, as described by Malchau et al. [11]. When the lesser trochanter was absent or not visible on radiographs, the measurements were conducted using the tip of the greater trochanter or cerclage wire as a marker and were recorded. Radiological evaluations were conducted using Beals and Towers’ criteria (Table 3) [12]. Any complication during the follow-up period was recorded.
A descriptive analysis of the continuous and categorical data was performed using proportions, frequency distributions, means and standard deviations. No statistical analysis was performed in this descriptive follow-up study.
Results
The average Harris Hip Score was 68.2 ± 18.4 (range, 32–100), and the average Barthel ADL index was 80.1 ± 19.75 (range, 30–100) points at the final follow-up. All fractures were united, and a good graft consolidation was achieved in 5 of 9 (Vancouver type B3) cases (Figs. 1, 2). There was femoral stem subsidence in 4 cases less than 10 mm without an evidence of loosening both radiologically and clinically. There were two superficial wound infections that were treated with antibiotherapy. S. aureus was isolated from the wounds. No cases had deep implant infection that required removal of the implant (prosthesis), but, in one case, we had to remove the distal cerclage wires that were thought as the focus of infection (Fig. 3). Posterior hip dislocation occurred in one patient at the 2nd postoperative month and was managed with closed reduction and abduction bracing and bed rest (Fig. 4). A new fracture occurred at the tip of the revision stem (Vancouver type B1) in one patient and was fixed with Dall-Miles plate, screws and cerclage wires (Fig. 5). No systemic complications occurred. The radiological results using Beals and Towers’ criteria were excellent in 8 hips, good in 5 and poor in 4. All results are summarized in Table 4.
Discussion
The goals of treatment in periprosthetic femoral fractures are providing fracture union, anatomic alignment, return of functional status, early mobilization, achieving a stable prosthesis at the end of fracture healing and a reasonable survivorship of the prosthesis [6, 13]. However, it is not always easy to obtain all these goals in these patients. Osteoporosis, poor bone stock, limited competence for mobility and often presence of co-morbidities due to advanced age may be listed as major obstacles. Among periprosthetic femoral fractures, Vancouver type B2 and B3 are the most challenging subtypes. According to Duncan and Masri, the treatment of type B2 fractures necessitates a revision surgery for femoral stem as the femoral stem is loose, with or without additional extramedullary fracture fixation. On the other hand, in type B3 fractures, poor bone stock should be reconstituted with allografts in addition to revision of the femoral stem [5, 6].
Long femoral stems have been favored for the treatment of Vancouver type B2 and B3 periprosthetic fractures in the present literature. Long femoral stem prosthesis act as an intramedullary nail and lock at the distal attachment; thus, both the revision arthroplasty and the fracture fixation can be achieved simultaneously. Furthermore, point of the fixation is remote from the fracture; therefore, the stability of the stem is not influenced by the fracture, and the fracture healing is not influenced by the undesirable effects of the fixation [14]. The prosthesis can be replaced by a cemented or non-cemented femoral stems. However, the cement may leak to the fracture site and impede fracture healing. In order to avoid detrimental effect of cement on fracture healing, distally cemented modular femoral stem have been used [15]. Besides high rate of nonunion, early loosening and refracture rate seems to be higher with cemented technique [8, 12, 16].
In this study, the results of revision hip arthroplasty with long distally fixed uncemented femoral stem in the management of Vancouver type B2 and B3 were investigated. In 13 out of 17 cases, we achieved excellent and good results. Fracture union was achieved in all cases. Four patients had poor results. Two of these patients with poor results had infection. Of these patients, one was a heavy smoker (20/day for 25 years) and had chronic renal failure. The other patient with infection had Type II diabetes mellitus and overweight (BMI = 29.3). One patient had refractured at the distal end of the revision stem with minor trauma. This patient had osteoporosis (BMD, T score <−2.5). Finally, one had posterior dislocation. In this patient, index fracture was an intertrochanteric fracture with greater trochanteric comminution, and the abductor lever was damaged. Complications and poor results were seen in patients with associated co-morbidities and risk factors. Preoperative identification of these risk factors may guide surgeons to predict the possible complications and prognosis.
The results of our series are similar to those previous reports which used distally locked uncemented femoral stems. Fink et al. prospectively reviewed 32 cases of periprosthetic femoral fractures (22 type B2 and 10 type B3) who were treated with non-cemented, modular tapered and fluted distally fixed titanium revision stem with a mean follow-up of 32 months. All patients in his series resulted with excellent outcome without nonunion, or subsidence [14]. Oshea et al. performed a retrospective clinical and radiographic assessment of 22 patients (10 B2, 12 B3) with a mean follow-up of 33.7 months. Uncemented extensively porous-coated distally fixed femoral stems were used for the revision. They reported 91 % of union rate. The outcome was excellent in 18 cases, good in one and poor in three. These three included the patient with residual infection, one with nonunion and one with unstable subsidence of the prosthesis [3]. Mulay et al. reviewed 24 patients (average age, 74 years) with types B2 and B3 fractures managed with a cementless, tapered, fluted and distally fixed stem using a transfemoral approach. Similarly, they reported 91 % of union rate. Fourteen of the 24 patients made an uneventful recovery without any major or minor complication [17]. Park et al. retrospectively analyzed 27 hips with periprosthetic femoral fractures (types B2 and B3) treated with distal fixation using a modular, fluted, femoral stem. The average follow-up was 4.8 years. Most fractures (25 hips) were united (92.6 %). Treatment failure occurred in 2 patients; one due to infected nonunion and the other due to subsidence (≥10 mm) associated with nonunion [18].
Modular femoral stems have some advantages over non-modular stems in control of leg length inequality. Mulay et al. [17] claimed that non-modular stems with a single offset without modularity may give rise to problems of over advancement of the definitive stem with possible increased risks of shortening and dislocation. In our series, there was subsidence in five patients, which were all less than 10 mm, and only one posterior dislocation. Similar subsidence and dislocation rates were also reported with modular femoral stems in the relevant literature [3, 18]. Cortical onlay allografts not only provide additional support to the rotational stability, but also enhance the osteogenesis of both fracture and regain the deficient bone stock in Vancouver type B3 fractures [19, 20]. In current study, we have used onlay strut grafts which were fixed with cerclage wires in all B3 fractures. At the final follow-up, there was no complication related to use of onlay strut grafts in this series.
Although this study has some limitations which include the retrospective nature of data collection, relatively short-term length of follow-up and the small patient population, uncemented long femoral stems together with or without onlay strut allografts provide a good fracture stability that promotes fracture healing. Types B2 and B3 femoral periprosthetic fractures represent one of the most difficult reconstructive surgeries. Uncemented distally locked long femoral stems with or without cortical onlay strut allografts offer a useful and successful solution.
References
Lindahl H, Malchau H, Herberts P, Garellick G (2005) Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the Swedish National Hip Arthroplasty Register. J Arthroplasty 20(7):857–865
Adolpson P, Jonsson U, Kalen R (1987) Fractures of the ipsilateral femur after total hip arthroplasty. Arch Orthop Trauma Surg 106(6):353–357
O’Shea K, Quinlan JF, Kutty S, Mulcahy D, Brady OH (2005) The use of uncemented extensively porous-coated femoral components in the management of Vancouver B2 and B3 periprosthetic femoral fractures. J Bone Jt Surg Br 87(12):1617–1621
Dysart SH, Savory CG, Callaghan JJ (1989) Non-operative treatment of a post-operative fracture around an uncemented porous-coated femoral component. J Arthroplasty 4(2):187–190
Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304
Masri BA, Meek RM, Duncan CP (2004) Periprosthetic fractures evaluation and treatment. Clin Orthop Relat Res 420:80–95
Brady OH, Garbuz DS, Masri BA, Duncan CP (2000) The reliability and validity of the Vancouver classification of femoral fractures after hip replacement. J Arthroplasty 15:59–62
Mont MA, Maar DC (1994) Fractures of the ipsilateral femur after hip arthroplasty: a statistical analysis of outcome based on 487 patients. J Arthroplast 9:511–516
Harris WH, Crothers O, Indong O (1977) Total hip replacement and femoral head bone grafting for severe acetabular deficiency in adults. J Bone Jt Surg 59-A:752–759
Mahoney FI, Barthel DW (1965) Functional evaluation: the Barthel index. Md State Med J 14:61–65
Malchau H, Karrholm J, Wang YX, Herberts P (1995) Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand 66(5):418–424
Beals RK, Tower SS (1996) Periprosthetic fractures of the femur: an analysis of 93 fractures. Clin Orthop Relat Res 327:238–246
Ko PS, Lam JJ, Tio MK, Lee OB, Ip FK (2003) Distal fixation with Wagner revision stem in treating Vancouver type B2 periprosthetic femur fractures in geriatric patients. J Arthroplasty 18(4):446–452
Fink B, Grossmann A, Singer J (2011) Hip revision arthroplasty in periprosthetic fractures of Vancouver type B2 and B3. J Orthop Trauma. Oct 18. [Epub ahead of print]
Zaki SH, Sadiq S, Purbach B, Wroblewski BM (2007) Periprosthetic femoral fractures treated with a modular distally cemented stem. J Orthop Surg (Hong Kong) 15(2):163–166
Wroblewski BM, Browne AO, Hodgkinson JP (1992) Treatment of the shaft of the femur in total hip arthroplasty by a combination of a Kuntscher nail and a modified cemented Charnley stem. Injury 23(4):225–227
Mulay S, Hassan T, Birtwistle S, Power R (2005) Management of types B2 and B3 femoral periprosthetic fractures by a tapered, fluted, and distally fixed stem. J Arthroplasty 20(6):751–756
Park MS, Lim YJ, Chung WC, Ham DH, Lee SH (2009) Management of periprosthetic femur fractures treated with distal fixation using a modular femoral stem using an anterolateral approach. J Arthroplasty 24(8):1270–1276
Wang JW, Wang CJ (2000) Periprosthetic fracture of the femur after hip arthroplasty: the clinical outcome using cortical strut allografts. J Orthop Surg (Hong Kong) 8(1):27–31
Brady OH, Garbuz DS, Masri BA, Duncan CP (1999) The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts. Orthop Clin North Am 30(2):249–257
Conflict of interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Canbora, K., Kose, O., Polat, A. et al. Management of Vancouver type B2 and B3 femoral periprosthetic fractures using an uncemented extensively porous-coated long femoral stem prosthesis. Eur J Orthop Surg Traumatol 23, 545–552 (2013). https://doi.org/10.1007/s00590-012-1024-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-012-1024-x