Abstract
Only a few reports exist on the management of severe anteroinferior glenoid defects in case of recurrent shoulder instability most of them including open approaches. We describe an all-arthroscopic reconstruction technique of the anteroinferior glenoid that includes an autologous iliac crest bone grafting using bio-compression screws and a capsulolabral repair using suture anchors. This technique recreates the bony and soft-tissue anatomy of the anteroinferior glenoid while preserving the integrity of insertion of the subscapularis (SSC) tendon.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Chronic anteroinferior glenoid bone deficiency has been reported in up to 90% of cases of recurrent anteroinferior shoulder instability [20]. With a large glenoid rim defect the shape of the glenoid changes to an “inverted pear” where the superior half is wider than the lower half [2, 3]. Glenoid bone loss shortens the safe arc through which the glenoid can resist axial forces. Biomechanical studies have shown an inverse relationship between the size of the glenoid defect and the stability of the shoulder: the larger the defect, the less the stability [6, 9, 11]. Clinical studies have confirmed that major bone loss is associated with an unfavourable or at least unpredictable outcome after arthroscopic Bankart-repair [2, 14].
Different open intra- and extra-articular bone grafting techniques have been described for the treatment of large glenoid rim deficits [4, 5, 7, 19, 21]. Recently published studies reported on the open anatomical glenoid reconstruction using an intraarticular tricortical iliac crest bone grafting technique [19, 21]. The authors achieved good and excellent clinical results with regards to shoulder stability and patient satisfaction. In addition union and incorporation of the graft was achieved in all cases. The open surgical procedure requires take-down of the subscapularis (SSC) tendon. Despite previously thought that this approach might not significantly disturb the integrity of the SSC musculotendinous unit, postoperative SSC dysfunction due to failure of the tendon repair and/or muscular changes (atrophy and fatty infiltration of the SSC muscle) have recently been described and appears to occur more frequently than previously appreciated [12, 15–18].
We describe an all-arthroscopic reconstruction technique of the anteroinferior glenoid that includes an autologous iliac crest bone grafting using bio-compression screws and a capsulolabral repair using bioabsorbable suture anchors (Arthrex, Naples, FL). This technique recreates the bony and soft-tissue anatomy of the anteroinferior glenoid while preserving the integrity of the insertion of the SSC tendon.
Preoperative work-up and planning
The diagnosis of recurrent shoulder instability is established by history, clinical examination and radiographic evaluation. On clinical examination a complete physical exam of the shoulder is performed to evaluate any potential concomitant lesions. Patients with severe glenoid defects typically present with midrange-of-motion instability [21]. Clinical signs for anterior instability in particular the apprehension and relocation tests are found to be positive. Although a bony defect of the anteroinferior glenoid can be diagnosed on plane radiographs and on oblique sagittal or axial MR- or CT-images we prefer to use a 3-D-CT imaging with subtraction of the humeral head and en face view of the glenoid as suggested by Sugaya [20] (Fig. 1). Gerber and Nyffeler have shown that if the length of the glenoid defect exeeds the maximum anteroposterior radius of the glenoid then the dislocation resistance decreases to no more than 70% of the value of an intact joint [6]. In our practice we use this criteria for the decision making of autologous bone grafting.
Surgical technique
Under general anaesthesia and perioperative antibiotics the patient is placed in the lateral decubitus position with 5 kg of horizontal and 3 kg of vertical arm traction. The shoulder and the ipsilateral iliac crest are prepped and draped in a steril fashion. A diagnostic arthroscopy is performed through a standard posterior portal. An anteroinferior working portal just above the SSC tendon through the rotator interval and a anterosuperior viewing portal just behind the biceps tendon are established using an outside-in technique. With the arthroscope switched to the anterosuperior portal the inverted-pear shaped appearance of the glenoid is visualized. A 8.25 mm × 7 cm translucent twist-in cannula is inserted via the anteroinferior portal and another 6 mm × 7 cm cannula via the posterior portal (Arthrex, Naples, FL) (Fig. 2). Next a deep anteroinferior 5 o′clock working portal is established through the inferior aspect of the SSC.
Again a 8.25 mm × 9 cm twist-in cannula is inserted via the deep anteroinferior portal. After the diagnosis is verified and other potential pathologies are excluded the next step includes the harvesting of the iliac crest bone graft that is performed as described by Warner et al. for the open bone grafting technique [21] (Fig. 3). The tricortical graft is contoured ex-vivo using an oscillating saw to recreate the inferior glenoid circle.
With the arthroscope in the anterosuperior portal and the Bankart-knife/shaver in the anteroinferior portal the glenoid neck is exposed and glenoid preparation is performed by mobilizing the capsulolabral complex medially (Fig. 4). Mobilization is conducted beyond the 6 o′clock position. An arthroscopic bur is used to abrade the medial wall of the glenoid to create a suitable bed for bony healing. The prepared iliac crest bone graft is introduced inside the joint using a clamp via the anterosuperior portal while the twist-in cannula is temporarily removed (Fig. 5). After placing the graft in position it is temporarily fixed using three K-wires. The position of the graft relative to the joint line is established using a standard Wisinger rod that is inserted via the posterior portal. The first K-wire is introduced via the deep anteroinferior portal, the second percutaneously through the upper part of the SSC tendon and the third via the anteroinferior portal (Fig. 6). The inferior and afterwards the superior K-wire are overdrilled using a cannulated drill bit and the graft is fixed using two 2.7–3.7 mm bio-compression screws (Arthrex, Naples, FL) (Fig. 7). If the defect is located more inferior than anterior both screws are introduced via the deep anteroinferior portal. The screws are placed underneath the joint line to avoid screw impingement. In cases of glenoidal incongruity due to prominence of the graft a small bur is used to restore the glenoid depth. Finally bioabsorbable Fastak-suture anchors armed with Fiber-wire (Arthrex, Naples, FL) are placed superiorly and inferiorly to the graft and the capsuloligamentous complex is reattached using horizontal mattress stitches (Fig. 8). The final construct reveals a reconstructed anteroinferior glenoid (Fig. 9). The arthroscopic portals are closed in a standard fashion.
Postoperative management
Postoperative management included immobilization in a sling (Ultrasling ER 15°, DJO, Carlsbad, CA) for 6 weeks. Physical therapy involved passive range of motion exercises during that time. Flexion in internal rotation was limited to 90° and external rotation in adduction was limited to 20°. At 7 weeks active range of motion exercises are initiated. After 12 weeks an intensive strengthening program including deltoid, rotator cuff and scapulothoracic muscles is started.
Discussion
Reestablishing the bony buttress to accommodate the axial and shear forces present in the glenohumeral joint is the ultimate goal in the treatment of anterior-inferior glenoid deficiency [2, 3]. Different surgical techniques for approaching chronic glenoid rim defects have been reported in the literature including the coracoid process transfer procedures as well as intra- or extraarticular iliac crest bone grafting techniques. The Latarjet or Bristow procedure has been described as a nonanatomical solution to this problem [1, 3, 4, 8, 10].
Warner et al. proposed the intraarticular autologous tricortical iliac crest bone grafting technique in response to some of the limitations seen with coracoid process transfer (for example loss of motion, hardware impingement, loosening or non-union of the bone graft and difficulties at revision surgery) [21]. We were able to confirm the reliable results achieved by Warner et al. for the open autologous iliac crest bone grafting technique combined with a capsulolabral repair in terms of stability and the good to excellent overall clinical outcome demonstrated by 5 well-established shoulder scores [19]. In both studies no hardware related problems due resorption and/or non-union of the iliac crest were observed. In fact CT-imaging obtained after surgery revealed a consolidated autograft in all cases without signs of graft necrosis and/or resorption.
Based on these promising results we have started to perform this procedure via an all-arthroscopic approach. Beside the obvious general advantages of arthroscopy including better cosmesis, lower risk of infection, less scar formation, the possibility to allow a rapid home return and an accelerated rehabilitation program the described procedure has further potential benefits compared to the open approach. Clinical studies using open stabilization surgery indicate that anterior approaches to the shoulder using SSC tendon take-down or incision techniques may impair SSC recovery and cause irreversible changes of the muscle in particular fatty infiltration with or without failure of the tendon repair, all of which may result in permanent loss of SSC function [12, 15–18]. It recently has been shown that an all-arthroscopic approach does not significantly compromise clinical SSC function and structural integrity of the SSC musculotendineous unit [18].
Mochizuki et al. were the first who recently reported on an all-arthroscopic autologous bone graft with arthroscopic bankart repair for a large bony defect lesion caused by recurrent shoulder dislocation [13]. The authors performed this technique by an arthroscopic bone grafting from the acromion to the anteroinferior glenoid rim using two harvested cylindrical bone grafts from the lateral site of the acromion and transplanted them into the inferior glenoid rim. We prefer to use an autologous iliac crest bone graft as described for the open technique. We believe that due to the tricortical nature of the iliac crest a better anatomic reconstruction can be achieved compared to the acromial cylindrical grafts (Fig. 10). The bio-compression screw fixation (Arthrex, Naples, FL) offers excellent interfragmentary compression including a headless profile to promote healing.
In summary the all-arthroscopic reconstruction technique of the anteroinferior glenoid that includes an autologous iliac crest bone grafting using bio-compression screws and a capsulolabral repair using suture anchors recreates the anatomy of the anteroinferior glenoid while preserving the integrity of insertion of the SSC tendon.
References
Bigliani LU, Newton PM, Steinmann SP, Connor PM, McIlveen SJ (1998) Glenoid rim lesions associated with recurrent anterior dislocation of the shoulder. Am J Sports Med 26:41–45
Burkhart SS, DeBeer JF (2000) Traumatic glenohumeral bone defects and their relationship to failure of arthroscopic bankart repairs: significance of the inverted-pear glenoid and the humeral engaging Hill-Sachs lesion. Arthroscopy 16:677–94
Burkhart SS, DeBeer JF, Tehrany AM, Parten PM (2002) Quantifying glenoid bone loss arthroscopically in shoulder instability. Arthroscopy 18:488–91
Chen AL, Hunt SA, Hawkins RJ, Zuckerman JD (2005) Management of bone loss associated with recurrent anterior glenouhumeral instability. Am J Sports Med 26:764–72
Churchill RS, Moskal MJ, Lippitt SB, Matsen FA III (2001) Extracapsular anatomically contoured anterior glenoid bone grafting for complex glenohumeral instability. Tech Should Elbow Surg 2:210–18
Gerber C, Nyfeller RW (2002) Classification of glenohumeral joint instability. Clin Orthop Relat Res 400:65–76
Haaker RG, Eickhoff U, Klammer HL (1993) Intraarticular autogenous bone grafting in recurrent shoulder dislocations. Mil Med 158:164–9
Helfet AJ (1958) Coracoid transplantation for recurring dislocation of the shoulder. J Bone Joint Surg Br 40:198–202
Itoi E, Lee SB, Berglund LJ, Berge LL, An KN (2000) The effect of a glenoid defect on anteroinferior stability of the shoulder after bankart repair: a cadaveric study. J Bone Joint Surg Am 82:35–46
Latarjet M (1965) Techniques chirurgicales dans le traitemant de la luxation anteriointerne recidivante de l´epaule. Lyon Chir 61:313–18
Malicky DM, Soslowsky LJ, Blasier RB, Shyr Y (1996) Anterior glenohumeral stabilization factors: progressive effects in a biomechanical model. J Orthop Res 14:282–88
Maynou C, Cassagnaud X, Mestdagh H (2005) Function of subscapularis after surgical treatment for recurrent instability of the shoulder using a bone-block procedure. J Bone Joint Surg Br 87:1096–1101
Mochizuki Y, Hachisuka H, Kashiwagi K, Oomae H, Yokoya S, Ochi M (2007) Arthroscopic autologous bone graft with arthroscopic bankart repair for a large bony defect lesion caused by recurrent shoulder dislocation. Arthroscopy 23:529–36
Mologne TS, Provencher MT, Menzel KA, Vachon TA, Dewing CB (2007) Arthroscopic stabilization in patients with an inverted pear glenoid. Results in patients with bone loss of the anterior glenoid. Am J Sports Med 35(8):1276–1283
Picard F, Saragaglia D, Montbarbon E, Tourne Y, Thony F, Charbel A (1998) Anatomo-clinical effect of subscapular muscle vertical section in Latarjet procedure. Rev chir orthop 84:217–23
Sachs RA, Williams B, Stone ML, Paxton L, Kuney M (2005) Open Bankart repair. Correlation of results with postoperative subscapularis function. Am J Sports Med 33:1458–62
Scheibel M, Tsynman A, Magosch P, Schroeder RJ, Habermeyer P (2006) Postoperative subscapularis muscle insufficiency after primary and revision open shoulder stabilization. Am J Sports Med 34:1586–93
Scheibel M, Nikulka C, Dick A, Schroeder RJ, Gerber Popp A, Haas NP (2007) Structural integrity and clinical function of the subscapularis musculotendinous unit after arthroscopic or open shoulder stabilization. Am J Sports Med 35:1153–61
Scheibel M, Nikulka C, Dick A, Schroeder RJ, Gerber Popp A, Haas NP (2007) Reconstruction of chronic anteroinferior glenoid defects using an autogenous tricortical iliac crest bone grafting technique. Paper presented at the III. Closed meeting of the European Society for Shoulder and Elbow Surgery (SECEC/ESSSE), Frankfurt
Sugaya H, Moriishi J, Dohi M, Kon Y, Tsuchiya (2003) Glenoid rim morphology in recurrent anterior glenohumeral instability. J Bone Joint Surg Am 85:878–84
Warner JJ, Gill TJ, O`hollerhan, Pathare N, Millett PJ (2005) Anatomical reconstruction for recurrent anterior glenohumeral instability with glenoid deficiency using an autogenous tricortical iliac crest bone graft. Am J Sports Med 34:205–12
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Scheibel, M., Kraus, N., Diederichs, G. et al. Arthroscopic reconstruction of chronic anteroinferior glenoid defect using an autologous tricortical iliac crest bone grafting technique. Arch Orthop Trauma Surg 128, 1295–1300 (2008). https://doi.org/10.1007/s00402-007-0509-2
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-007-0509-2