Abstract
Aims
Cryoballoon technology is a promising technique in paroxysmal atrial fibrillation (AF) ablation. However, success rates in patients with persistent AF have not been convincing. There is a trend toward performing more extensive procedures that are referred to as ‘pulmonary vein isolation plus.’ To combine pulmonary vein isolation (PVI) and antral substrate modification, we used both the 23-mm and 28-mm cryoballoon in a single approach in patients with persistent AF.
Methods and results
33 consecutive patients (26 men, age 60 ± 10 years, LA size 44 ± 5 mm) with persistent AF were prospectively included. All patients underwent the “double balloon strategy:” at least two applications at each pulmonary vein (PV) using the smaller 23-mm balloon to isolate the PV at the ostial level plus at least one additional freeze by the 28-mm balloon at the wide PV antral level. 7-day Holter monitors were performed during follow-up at 1, 3, 6, 9, 12, 18 and 24 months post-ablation. 131 of 133 PVs were targeted and isolated (98.4 %). A mean of 14 ± 2 cryoballoon applications per patient or 3.5 ± 1.5 applications per vein were performed. After a single procedure and mean follow-up of 15 ± 3 months, 69.7 % of patients remained in sinus rhythm (3-month blanking period). There were no major complications.
Conclusions
In persistent AF, the “double balloon strategy;” combining the small and large cryoballoon allowed ostial PV isolation followed by antral cryoablation is feasible, safe and associated with a favorable outcome.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Catheter ablation is extensively used in the treatment of atrial fibrillation (AF) with curative intention. Cryoballoon technology (Arctic Front, Medtronic, USA) has emerged as a promising and safe approach to pulmonary vein isolation (PVI) in short and longterm follow-up of paroxysmal AF patients [1–5]. Two different sizes of the cryoballoon are currently available. A smaller (23 mm) and a larger (28 mm) balloon relative to the ostial diameter of the pulmonary veins (PV). A complete occlusion of the PV is key for PVI success. The largest trial was published by Neumann et al. [3] including 293 patients with paroxysmal AF and a success rate of 74 % of maintained sinus rhythm. However, in 53 patients with persistent AF, freedom from AF was observed in only 42 %. A similarly limited success rate of 48 % was reported recently in 34 patients with persistent AF [5].
Although ablation techniques and strategies vary among centers, there is a general trend favoring PVI alone for treatment of paroxysmal AF and PVI combined with left atrial substrate modification for treatment of persistent AF [6–8]. In persistent AF, more extensive procedures are performed which can be broadly referred to as ‘PV isolation plus.’
To induce substrate modification beyond PVI only at the ostial level of the PVs, we combined the use of both the 23 and 28-mm cryoballoon in one single approach in patients with persistent AF. The strategy was to combine cryoballoon induced ostial and wide antral lesions in each individual PV of the patients. We report our pilot study investigating a new “double cryoballoon strategy” approach in patients with persistent atrial fibrillation.
Methods
Patients
Between December 2009 and November 2010, 33 consecutive patients with symptomatic persistent AF were included in the prospective study. Persistent AF was defined as episodes of AF that lasted >7 days without intervention [9]. All patients underwent their first AF ablation procedure. In all study subjects, cryoballoon PVI using the “double balloon strategy” was performed at our institution.
Exclusion criteria were as follows: age <18 years or >80 years, repeat procedure for recurrent AF, ejection fraction <30 %, left atrial size >55 mm, left atrial thrombus, inability to consent and life expectancy <1 year.
All patients gave written informed consent prior to inclusion in the study. The local institutional ethics committee approved the study.
Ablation protocol
All PVI procedures were performed under conscious sedation and analgesia with appropriate doses of fentanyl and midazolam. A decapolar catheter was placed into the coronary sinus. After venous and arterial access for real-time blood pressure monitoring, a single transseptal puncture was performed under guidance of intracardiac ultrasound (ICE) using a modified Brockenbrough technique to introduce an 8-F sheath (St. Jude Medical, USA) and the steerable 12-F sheath for cryoballoon (FlexCath, Medtronic, USA) introduction. After transseptal puncture an infusion of heparin was maintained to achieve an activated clotting time of 300–400 s during the LA procedure. Activated clotting time measurements were performed every 30 min routinely. Pulmonary vein potentials were checked at least before and after PV isolation with a circular mapping catheter. To record the PV potentials during the cryoballoon freezes an 8-pole circular mapping catheter (Achieve, Medtronic, USA) was used which was introduced into the central lumen of the cryoballoon catheter.
If AF was present direct current cardioversion was performed to restore sinus rhythm prior to ablation start. To assess the exact position of the inflated balloon relative to the PV ostium, contrast agent (dye diluted in 1:1 ratio with 0.9 % saline) was injected from the distal lumen of the cryoballoon to obtain a PV angiogram. Cryoballoon occlusion of the vein was quantified according to a semiquantitative grading method described earlier (from grade 4 = excellent: full retention of contrast medium without outflow in the LA down to grade 1 = very poor with an immediate outflow from the vein) [3].
Cryoballoon ablation: double balloon strategy
To combine ostial PV isolation and wider PV antral lesions, both balloons were used in a single procedure (Fig. 1). First, the smaller balloon was introduced. At least two applications (300 s per freeze) using the 23-mm balloon at the PV ostial level were performed. For freezes of the RSPV the small balloon was not used if the maximum diameter of the PV exceeded 21 mm to minimize the risk of phrenic nerve injury. PV isolation (defined as PV entrance block with complete loss of all PV signals) was confirmed by the 8-pole circular mapping catheter. After PV isolation was achieved one safety freeze was performed. Local temperature in the PV antrum was continuously monitored from a temperature sensor at the proximal part of the cryoballoon. If complete PV isolation was confirmed by the circular mapping catheter the bigger 28-mm cryoballoon was introduced and at least one additional freeze at the wide PV antral level was added. Using the double balloon strategy all individual PVs were treated as described including left common os and additional right middle PV if present.
At the end of the procedure the electrophysiological end point of entrance block was reconfirmed using the circular mapping catheter for each PV.
If typical atrial flutter had been previously documented during electrocardiographic monitoring, cavotricuspid isthmus ablation was performed using an 8-mm tipped radiofrequency catheter (Gold-tip Flex cathether, Biotronik, Germany) (70W, 60C) until bidirectional isthmus block was achieved.
Peri-operative safety care
The day prior to the procedure, transthoracic echocardiography to assess LA diameter and left ventricular ejection fraction and transesophageal echocardiography was performed, to rule out LA thrombus formation. A CT scan was performed prior to the ablation procedure in all patients. After segmentation of the left atrium, the left atrial volume and pulmonary vein diameters were analyzed.
Phrenic nerve monitoring: A deflectable quadripolar catheter was introduced via the left femoral vein for pacing in the superior vena cava to capture the right phrenic nerve. Continuous monitoring of the phrenic nerve during ablation of the right superior and inferior PV either was performed in all patients to reduce the risk of phrenic nerve palsy (PNP). Cryoballoon applications were immediately terminated in case of any attenuation of the strength of right hemidiaphragmatic contractions.
Anticoagulation: In patients receiving oral anticoagulants, warfarin was stopped 5 days prior to the procedure with bridging tinzaparin (175 IU/kg). Post-ablation all patients were heparinized with tinzaparin 175 IU/kg until oral anticoagulation with phenprocoumon with a target INR of 2.0–3.0 for at least 3 months was reassumed.
Intracardiac echocardiography guidance of the procedure
All freezes and navigation of the cryoballoon catheter were monitored by the use of ICE (AcuNav, Siemens Medical Solution, Germany). The catheter was introduced through an 11-Fr sheath via the left femoral vein and positioned, fluoroscopically guided, into the right atrium. The electrophysiologist then optimized the ICE images. The position of the cryoballoon at the ostial and antral level of the PV was demonstrated. The whole antrum was visualized to optimize Doppler alignment for each PV during freezing. The optimal position of the cryoballoon in relation to the ostial and antral level of the PV was assessed utilizing ICE, visualized as a full occlusion of the PV with documented loss of Doppler coded reflow to the left atrium and angiography (PV angiogram occlusion grade 4).
Post-ablation management and follow-up
Pericardial effusion and pulmonary infiltration were ruled out in all patients with a transthoracic echocardiography and a chest X-ray following ablation. A 24-h Holter ECG was performed in all patients between day 1 and day 3 post-ablation. Antiarrhythmic drugs were continued 3 months after the procedure to facilitate maintenance of sinus rhythm. At 3 months antiarrhythmics were stopped or continued according to the clinical follow-up and the discretion of the treating electrophysiologist.
During follow-up, all patients were advised to contact us at any time in case of palpitations for ECG registration. They were prospectively followed and underwent an outpatient visit at 1, 3, 6, 9, 12, 18 and 24 months post-ablation. Follow-up included clinical examination, ECG, transthoracic echocardiography and 7-day Holter ECG monitoring to detect recurrence of AF. An event recorder was applied in case of rare palpitations without ECG documentation. Recurrent AF was defined as any symptomatic or asymptomatic detected episode lasting >30 s [9].
Endpoint
The primary endpoint of the study was freedom from AF recurrence. Procedure-related complications was the secondary endpoint.
Statistical analysis
Continuous variables are reported as mean ± standard deviation (SD) or median. Categorical variables are reported as numbers and percentages. Continuous variables were analyzed for a normal distribution using the Kolmogorov–Smirnov test. Comparison of continuous variables was performed using the Student’s t test.
Event-free survival was calculated according to the Kaplan–Meier method, with time of first recurrence of atrial fibrillation as the outcome variable including a blanking period of 3 months p < 0.05 considered significant.
Analysis was performed using the Statistical Package for the Social Sciences (version 19.0, SPSS, Inc., Chicago, USA). The authors had full access to and take full responsibility for the integrity of the data. All authors have read and agree to the written manuscript.
Results
Patients
Patient characteristics are presented in Table 1. 33 consecutive patients (26 men; mean age 60 ± 11 years) with persistent AF were included in the study. Mean AF history prior to ablation was 51 ± 40 months (range 4–132 months) and the mean duration of the last persistent AF episode was 109 ± 112 days (median: 31 days; range 9–744 days) prior to PV ablation. Antiarrhythmic therapy had failed using a mean number of 2 ± 1 antiarrhythmic drugs (AAD). Mean left atrial diameter by echocardiographic parasternal long axis view was 44 ± 6 mm. Typical PV anatomy consisting of 4 distinct PV were found on preprocedural segmentation of CT scans in 28 patients. Two patients had a left common os, an additional right middle PV was found in three patients. The size determined as the maximum diameter of the PVs was as follows:
LSPV: mean 19.8 ± 2.7 mm, median 19 mm, range (15–24 mm), LIPV: mean 20.9 ± 4 mm, median 20 mm, range (13.6–29.6 mm), RIPV: mean 19.8 ± 3.2 mm, median 19 mm, range (13–28 mm) and RSPV: mean 21.7.8 ± 2.6 mm, median 22 mm, range (16.9–26 mm).
Acute procedural results
In 33 patients, a total of 133 PVs including 2 with left common ostia were identified and treated. 131 of the 133 PVs (98.4 %) were electrically isolated using the cryoballoon technique exclusively. No PV reconduction was observed until the end of the procedure.
Procedural data
The mean procedural duration was 209 ± 53 min. The mean fluoroscopy time was 48 ± 11 min resulting in a mean dose area product of 5754 ± 3536 cGy. The mean volume of contrast medium used was 157 ± 55 ml.
A mean of 14 ± 2 cryoballoon freezes were applied per patient. Mean number of balloon applications per vein was 3.5 ± 1.5. Minimum cryoballoon temperatures (local temperature at the proximal part of the cryoballoon) during freezing were −75 ± 7 for LSPV, −76 ± 10 for LIPV, −69 ± 7 for RSPV and −72 ± 9 for RIPV using the 23 mm balloon and −50 ± 7 for LSPV, −45 ± 11 for LIPV, −49 ± 7 for RSPV and −52 ± 9 for RIPV utilizing the 28 mm balloon. Radiofrequency cavotricuspid isthmus block was successfully performed in one patient.
Follow-up and AF recurrence
All patients were discharged in sinus rhythm. 7-day Holter ECG monitoring was performed for a median of 15 months (range 12–26 months) post-ablation. At least 12 months of follow-up was completed by all patients. Stable sinus rhythm as the primary endpoint was documented throughout the follow-up period in 23/33 patients (69.7 %, 3-month blanking period, Fig. 2) and in 21/33 patients (63.6 %, without blanking period). Antiarrhythmic drugs were discontinued in 17 patients (52 %) 3 months and in 28 patients (85 %) 6 months post-AF ablation. No organized atrial tachycardias were detected during follow-up, with AF being the only recurrent arrhythmia. A repeat procedure was performed in three patients with symptomatic AF recurrence within 12 months after the index ablation. In all repeat procedures the “double balloon strategy” was performed as described above with respect to PV reconnection confirmed by remapping the PVs during the redo procedure.
Predictors of AF recurrence
Screening for predictors of AF recurrence included age, hypertension, coronary artery disease, left atrial diameter, ejection fraction, use of antiarrhythmics, trough balloon temperature and grading of PV occlusion (dye contrast reflow in LA). Hypertension was the only predictor for AF recurrence (Table 2).
Procedural complications
There were no major periprocedural complications including thromboembolic events, PV stenoses or tamponades observed in our patients. One minor complication occurred in 33 patients (3 %). One patient suffered from an aneurysma spurium the day after ablation which could be successfully treated by manual compression.
In one patient a freeze using the 28-mm cryoballoon at the RSPV was immediately terminated when phrenic nerve capture was lost. Phrenic nerve function recovered completely within 2 min after the freeze was terminated. The ratio of PV size (maximum diameter 26 mm) to balloon size (28 mm) was 0.93. According to our protocol a 23-mm balloon had not been used to treat this PV.
Discussion
Ablative treatment of persistent AF with curative intention remains challenging. For the first time, the present study reports on a novel “double cryoballoon strategy” utilizing both the smaller 23-mm and the larger 28-mm cryoballoon in a single ablation procedure. Our study demonstrates this strategy can be performed safely and effectively with a success rate of 69.7 % freedom from AF after follow-up of 15 ± 3 months in patients with persistent atrial fibrillation. Furthermore, although both cryoballoon sizes were used in a single procedure the complication rate was rather low without major complications.
Previous data and role of atrial substrate in persistent AF
Published outcome data in AF ablation show variable results related to the ablation method used, patient selection and follow-up. A recent review of the literature revealed an efficacy of 60–80 % freedom from AF at 12 months follow-up with a single AF ablation procedure in well selected patients with paroxysmal AF. In persistent (50–70 %) and longstanding persistent (below 50 %) AF patients, efficacy rates are not optimal [5, 7, 10]. While the endpoint of PVI is the agreed goal in paroxysmal AF [9], the targets and endpoints of ablation for persistent AF are not well defined yet [11].
Considerable experimental and clinical evidence suggests that as AF progresses from paroxysmal to persistent, the atrial substrate becomes increasingly abnormal and may play a more important role in maintaining the arrhythmia [12–17].
Since the modification of the left atrial substrate seems to play an important part, there is a trend for more extensive procedures (‘PV isolation plus’) in radiofrequency (RF) ablation of persistent AF. Ablation lesions have migrated more proximally to ‘encircle’ the pulmonary vein antra, in order to enclose a larger region of posterior left atrial myocardium. Current strategies are based on achieving PVI prior to targeting left atrial substrate modification including ablation of complex fractionated electrograms, the creation of linear lesions, or both [8, 18, 19]. However, concerns have been raised that more extensive ablation may increase the risk of complications and impair left atrial mechanical properties [20–22].
In previous reports cryoballoon therapy had limited success in persistent AF patients (3–5). It was shown that PVI may not be sufficiently achieved in all pulmonary veins using a single size cryoballoon. Although it is well known that focal cryoablation catheters have limitations regarding their use in AF ablation therapy they had to be additionally used to complete PVI after insufficient single cryoballoon therapy [2, 4, 23]. Since PVI is the cornerstone in any AF ablation procedure a single cryoballoon size may not be sufficient, certainly in persistent AF patients.
It was presumed that the strategy of the cryoballoon device might not produce sufficient substrate modification as required in persistent AF [3]. In two separate series, detailed electroanatomical mapping was used before and after cryoballoon applications to determine the anatomical level at which PV isolation was achieved. When the 23-mm balloon was used, the PVs were found to be isolated at the ostial level, whereas use of the 28-mm larger balloon results in the formation of much wider, circumferential and antrally located lesions. Another trial revealed that the extent of PVI significantly differed when the lesions with either balloon sizes were compared. The lesion created with the 28-mm balloon included a larger portion of the left atrium. Using the 23-mm balloon the mean documented extent of electrical isolation was 20.7 ± 2.8 % of the maps’ surface, compared to 40.2 ± 3.9 % when performing ablation with the 28-mm balloon [24–26].
Mansour et al. [27] reported a combined approach using a cryoballoon for PVI and focal RF ablation to induce left atrial substrate modification in 22 persistent AF patients with promising procedural and short-term follow-up results in terms of efficacy and safety. However, the combination of cryo- and RF energy performed in a single approach in the left atrium means increased radiation and is time consuming and needs to be confirmed and approved in larger trials also with respect to safety and the patient periprocedural comfort.
Thus, our proposed double balloon approach using both cryoballoon sizes might overcome the limitations of prior single balloon therapies in persistent AF with respect to insufficient PVI in selected PVs due to a mismatch of balloon/diameter size and solely ostial lesion formation using the 23-mm cryoballoon only. Compared to the combined use of cryo- and RF energy our procedure and fluoroscopy times were shorter with promising efficacy and safety rates [27].
Predictors of success in “double balloon strategy” in persistent AF
Successful PVI using the cryoballoon approach requires optimized wall contact within the left atrium encircling the PVs. Incomplete wall contact may result in conduction gaps and prevent complete PVI which was shown primarily for the inferior aspect of the PVs during analysis of redo procedures [28]. Data from Kuck et al. [29] using a single big balloon only demonstrated an acute success rate of >98 % isolated PVs. However, these promising results could not be reproduced in other centers. Andrade et al. [30] found in their review of 23 cryoballoon studies an acute success rate of 92.6 % isolated PVs using the cryoballoon catheter alone without focal ablations. Including focal “touch-up” ablations using cryo or RF energy the acute success rate increased to 98.8 %. We also found a strong acute success rate of 98.4 % with 131 of 133 isolated PVs. Since our acute success rate translated in a freedom from AF of 69.7 % in persistent AF patients at 15 ± 3 months follow-up, this appears to be related to the use of both balloon sizes combining ostial and more antrally located lesions. In most patients` anatomy an optimized wall contact can be achieved more effectively with the 23-mm instead of the 28-mm balloon, but the PV isolation site of the 23-mm balloon would be more distal compared to the PV antrum. However, the PV antrum has been proven important for initiation as well as for maintenance of atrial fibrillation [31, 32]. Even in longstanding persistent AF patients and RF ablation pulmonary vein antrum isolation has been proven an important endpoint in maintaining SR which should be the cornerstone also in any ablation procedure in persistent AF patients [6, 33]. Thus, the combination of an optimized left atrial-PV wall contact more distally using the 23-mm balloon and the additional antral lesion formation using the 28-mm freeze seems to be key in the “double balloon strategy.”
In cryoballoon ablation temperature measurement is a less dependable predictor, since the temperature sensor, located proximally inside the balloon, is outside the PV and underestimates the tissue temperature attained during the freeze. The sensor is warmed by blood flow in neighboring PVs. In our patients a lower trough temperature was not associated with AF recurrence, which might be related to the limited numbers of patients included in this pilot study.
The time to PVI recorded by real-time monitoring of PV potentials throughout the freeze using a circular mapping catheter introduced into the central lumen of the cryoballoon catheter was reported as a promising tool. A cut-off value of 83 s to PV isolation was predictive of stable procedural PVI without reconduction [34]. Since time to PVI reflects the accuracy of the isolation of a single vein it was not predictive of AF recurrence in our persistent AF patients undergoing the “double cryoballoon strategy.” This might furthermore be related to the additive effect of the antral lesion formation using the 28-mm cryoballoon after PVI was achieved using the 23-mm balloon.
Complications
Our study supports prior data on the safety of cryoballoon therapy in AF. A major concern utilizing the cryoballoon is PNP. One transient PNP was induced using the 28-mm cryoballoon in a right superior PV with full recovery within 120 s after freeze termination. Our experience would support the recommendation to continuously monitor the phrenic nerve function by pacing in the superior vena cava to capture the right phrenic nerve and avoid a distal balloon ablation within the RSPV as discussed earlier [35, 36].
Although PNP is a major limitation of balloon catheters used in AF ablation, cryoballoon therapy has obvious significant potential safety advantages when compared with RF ablation. Certainly complex RF ablation strategies as recommended in patients with persistent AF carry a significant risk for major complications. Major complications were reported in up to 6 % including the risk of PV stenosis, thromboembolic events, tamponades or atrioesophageal fistula, which were not seen in our patients [11].
Limitations
The number of patients included in the study was relatively small. Since this was a pilot study, evaluating the “double balloon strategy” in terms of efficacy and safety in patients with persistent AF for the first time, larger trials are needed to confirm our findings. However, since 7-day Holters were performed in our patients at close intervals up to 24 months the follow-up of our patients was relatively intense. Of course, longterm follow-up will be important to demonstrate that our data will translate into a longterm freedom from AF in patients with persistent AF undergoing a “double balloon strategy” in cryoablation.
We did not find any symptoms suggestive of PV stenosis in our patients during follow-up and did not perform repeat imaging by use of CT scan or cardiac MRI scan to rule out subclinical PV stenosis. However, since all patients were asymptomatic, such a finding would not have changed the post-ablation management during follow-up.
Radiation exposure still is an issue in cryoballoon ablation. We found a mean dose area product of 5754 ± 3536 cGy and a fluoroscopy time 48 ± 11 min which was in line with data from a recent review of published studies in cryoballoon ablation [30]. The reduction of radiation exposure in cryoballoon ablation using alternative imaging modalities has to be addressed in future trials.
Finally, randomized studies evaluating the efficacy and safety of RF versus cryoballoon therapy will be necessary to compare the value of both ablation therapies in patients with persistent AF.
Conclusion
The results of this pilot study demonstrate that the “double balloon strategy” combining cryoballoon induced ostial PV isolation followed by antral cryoablation for treatment of persistent AF is feasible and is associated with a favorable outcome. Only minor transient and reversible complications occurred. A randomized study in a larger cohort of patients is required to assess efficacy and safety of this new approach in persistent AF patients.
Abbreviations
- AF:
-
Atrial fibrillation
- PV:
-
Pulmonary vein
- PVI:
-
Pulmonary vein isolation
- LA:
-
Left atrium
- LSPV:
-
Left superior pulmonary vein
- LIPV:
-
Left inferior pulmonary vein
- RSPV:
-
Right superior pulmonary vein
- RIPV:
-
Right inferior pulmonary vein
- SD:
-
Standard deviation
- ICE:
-
Intracardiac echocardiography
- PNP:
-
Phrenic nerve palsy
References
van Belle Y, Janse P, Rivero-Ayerza MJ, Thornton AS, Jessurun ER, Theuns D et al (2007) Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur Heart J 28(18):2231–2237
Klein G, Oswald H, Gardiwal A, Lüsebrink U, Lissel C, Yu H et al (2008) Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation. Heart Rhythm 5:802–806
Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H et al (2008) Circumferential pulmonary vein isolation with the cryoballoon technique: results from a prospective 3-center study. J Am Coll Cardiol 52(4):273–278
Dewire C, Calkins H (2010) State-of-the-art and emerging technologies for atrial fibrillation ablation. Nat Rev Cardiol 7:129–138
Kojodjojo P, O’Neill MD, Lim PB, Malcolm-Lawes L, Whinnett ZI, Salukhe TV et al (2010) Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart 96(17):1379–1384
Elayi CS, Verma A, DiBiase L, Ching CK, Patel D, Barrett C et al (2008) Ablation of longstanding permanent atrial fibrillation: results from a randomized study comparing three different strategies. Heart Rhythm 12:1658–1664
Natale A, Raviele A, Arentz T, Calkins H, Chen SA, HaÏssaguerre M et al (2007) Venice Chart international consensus document on atrial fibrillation ablation. J Cardiovasc Electrophysiol 18:560–580
Willems S, Klemm H, Rostock T, Brandstrup B, Ventura R, Steven D et al (2006) Substrate modification combined with pulmonary vein isolation improves outcome of catheter ablation in patients with persistent atrial fibrillation: a prospective randomized comparison. Eur Heart J 27:2871–2878
Calkins H, Brugada J, Packer DL, Cappato R, Chen SA, Crijns HJ et al (2007) HRS/EHRA/ECAS expert consensus statement on catheter surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force On Catheter And Surgical Ablation Of Atrial Fibrillation. Heart Rhythm 4:816–861
Cappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J et al (2005) Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation 111:1100–1105
O’Neill MD, Wright M, Knecht S, Jaïs P, Hocini M, Takahashi Y et al (2009) Long-term follow-up of persistent atrial fibrillation ablation using termination as a procedural endpoint. Eur Heart J 30(9):1105–1112
Oral H, Knight BP, Tada H, Ozaydin M, Chugh A, Hassan S et al (2002) Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation. Circulation 105:1077–1081
Allessie M, Ausma J, Schotten U (2002) Electrical, contractile and structural remodeling during atrial fibrillation. Cardiovasc Res 54:230–246
Katritsis D, Faisal M, Merchant M, Mela T, Singh JP, Heist K et al (2010) Catheter ablation for atrial fibrillation. The search for substrate-driven endpoints. J Am Coll Cardiol 55:2293–2298
Sadoshima J, Xu Y, Slayter HS, Izumo S (1993) Autocrine release of angiotensin II mediates stretch-induced hypertrophy of cardiac myocytes in vitro. Cell 75:977–984
Saygili E, Rana OR, Saygili E, Reuter H, Frank K, Schwinger RH et al (2007) Losartan prevents stretch-induced electrical remodeling in cultured atrial neonatal myocytes. Am J Physiol Heart Circ Physiol 292:H2898–H2905
Burstein B, Nattel S (2008) Atrial fibrosis: mechanisms and clinical relevance in atrial fibrillation. J Am Coll Cardiol 51:802–809
Oral H, Chugh A, Yoshida K, Sarrazin JF, Kuhne M, Crawford T et al (2009) A randomized assessment of the incremental role of ablation of complex fractionated atrial electrograms after antral pulmonary vein isolation for long-lasting persistent atrial fibrillation. J Am Coll Cardiol 53:782–789
Haïssaguerre M, Sanders P, Hocini M, Takahashi Y, Rotter M, Sacher F et al (2005) Catheter ablation of longlasting persistent atrial fibrillation: clinical outcome and mechanisms of subsequent arrhythmias. J Cardiovasc Electrophysiol 16:1138–1147
Jais P, Hocini M, Hsu LF, Sanders P, Scavee C, Weerasooriya R et al (2004) Technique and results of linear ablation at the mitral isthmus. Circulation 110:2996–3002
Wylie JV Jr, Peters DC, Essebag V, Manning WJ, Josephson ME, Hauser TH (2008) Left atrial function and scar after catheter ablation of atrial fibrillation. Heart Rhythm 5:656–662
Lemola K, Desjardins B, Sneider M, Case I, Chugh A, Good E et al (2005) Effect of left atrial circumferential ablation for atrial fibrillation on left atrial transport function. Heart Rhythm 2:923–928
Malmborg H, Lönnerholm S, Blomström-Lundqvist C (2008) Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation. Europace 10:1271–1276
Reddy VY, Neuzil P, d’Avila A, Laragy M, Malchano ZJ, Kralovec S et al (2008) Balloon catheter ablation to treat paroxysmal atrial fibrillation: what is the level of pulmonary venous isolation? Heart Rhythm 5:353–360
Van Belle Y, Knops P, Janse P, Rivero-Ayerza M, Jessurun E, Szili-Torok T et al (2009) Electro-anatomical mapping of the left atrium before and after cryothermal balloon isolation of the pulmonary veins. J Interv Card Electrophysiol 25:59–65
Chierchia GB, de Asmundis C, Sorgente A, Paparelle G, Sarkocy A, Müller-Burri SA et al (2011) Anatomical extent of pulmonary vein isolation after cryoballoon ablation for atrial fibrillation: comparison between the 23 and 28 mm balloons. J Cardiovasc Med (Hagerstown) 12(3):162–166
Mansour M, Forleo GB, Pappalardo A, Barrett C, Heist EK, Avella A et al (2008) Combined use of cryoballoon and focal open-irrigation radiofrequency ablation for treatment of persistent atrial fibrillation: results from a pilot study. Heart Rhythm 7(4):452–458
Fürnkranz A, Chun KRJ, Nuyens D, Metzner A, Köster I, Schmidt B et al (2010) Characterization of conduction recovery after pulmonary vein isolation using the “single big cryoballoon” technique. Heart Rhythm 7(2):184–190
Kuck KH, Fürnkranz A (2010) Cryoballoon ablation of atrial fibrillation. J Cardiovasc Electrophysiol 21(12):1427–1431
Andrade JG, Khairy P, Guerra PG, Deyell MW, Rivard L, Macle L et al (2011) Efficacy and safety of cryoballoon ablation for atrial fibrillation: a systematic review of published studies. Heart Rhythm 8(9):1444–1451
Ouyang F, Ernst S, Chun J, Bänsch D, Li Y, Schaumann A et al (2005) Electrophysiological findings during ablation of persistent atrial fibrillation with electroanatomic mapping and double Lasso catheter technique. Circulation 112:3038–3048
Haïssaguerre M, Sanders P, Hocini M, Hsu LF, Shah DC, Scavée C et al (2004) Changes in atrial fibrillation cycle length and inducibility during catheter ablation and their relation to outcome. Circulation 109:3007–3013
Tilz RR, Chun KRJ, Schmidt B, Fürnkranz A, Wissner E, Köster I et al (2010) Catheter ablation of long-standing persistent atrial fibrillation: a lesson from circumferential pulmonary vein isolation. J Cardiovasc Electrophysiol 21:1085–1093
Dorwarth U, Schmidt M, Wankerl M, Krieg J, Straube F, Hoffmann E (2011) Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural success. J Interv Card Electrophysiol (Epub ahead of print)
Chun KRJ, Schmidt B, Metzner A, Tilz R, Zerm T, Köster I et al (2009) The “single big cryoballoon” technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J 30:699–709
van Belle Y, Janse P, Rivero-Ayerza MJ et al (2007) Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur Heart J 28(18):2231–2237
Conflict of interest
No disclosures relevant to the manuscript have to be declared.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Schmidt, M., Dorwarth, U., Straube, F. et al. A novel double cryoballoon strategy in persistent atrial fibrillation: a pilot study. Clin Res Cardiol 101, 777–785 (2012). https://doi.org/10.1007/s00392-012-0456-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00392-012-0456-y