Abstract.
Planar laser-induced fluorescence (PLIF) images of NO concentration are reported in premixed laminar flames from 1–60 bar exciting the A-X(0,0) band. The influence of O2 interference and gas composition, the variation with local temperature, and the effect of laser and signal attenuation by UV light absorption are investigated. Despite choosing a NO excitation and detection scheme with minimum O2-LIF contribution, this interference produces errors of up to 25% in a slightly lean 60 bar flame. The overall dependence of the inferred NO number density with temperature in the relevant (1200–2500 K) range is low (<±15%) because different effects cancel. The attenuation of laser and signal light by combustion products CO2 and H2O is frequently neglected, yet such absorption yields errors of up to 40% in our experiment despite the small scale (8 mm flame diameter). Understanding the dynamic range for each of these corrections provides guidance to minimize errors in single shot imaging experiments at high pressure.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Author information
Authors and Affiliations
Additional information
Received: 13 May 2002 / Published online: 8 August 2002
Rights and permissions
About this article
Cite this article
Bessler, W., Schulz, C., Lee, T. et al. Quantitative NO-LIF imaging in high-pressure flames. Appl Phys B 75, 97–102 (2002). https://doi.org/10.1007/s00340-002-0946-0
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00340-002-0946-0