1 Introduction

The integration of graphene-based system with modern technology has led towards its application in numerous optoelectronic devices [1]. The emergence of beyond graphene two-dimensional (2D) materials (e.g. phosphorene, transition metal dichalcogenides (TMDs), hexagonal boron nitrides, etc.) [2,3,4,5] has predicted their excellent integration. The quantum confinement has led to the advancement in the properties (chemical, physical and optical) of monolayer 2D materials from their bulk counterparts [2]. Moreover, the discovery of 2D Ti3C2Tx in 2011 has open up new possibilities for its application [6]. It was assigned the name “MXene” due to its graphene-like morphology. The combination of the two imperative properties of metallic conductivity and hydrophilicity shown by MXene is one of the advantages over other 2D materials [7]. In addition, 2D structure of MXenes possesses a large surface area which makes them a promising material for application in electrochemical energy storage. Further, MXene-based device for wireless communication was reported by Sarycheva et al. [8]. Recently, Velusamy et al., demonstrated the first plasmonic photodetector utilising Mo2CTx MXene [9]. Apart from the discussed optoelectronics applications, MXene has witnessed its application in biomedical fields viz., bioimaging, biosensors, antibacterial and theranostics [10]. In the context of biosensors, surface plasmon resonance (SPR)-based sensors in particular, MXene is burgeoning as a promising material for performance enhancement of the detection scheme [11,12,13]. The transverse magnetic (TM) wave oscillations existing at metal–dielectric interfaces are usually referred as SPR [14]. The accurate sensing mechanism, ease of fabrication and low cost experimental arrangements have made SPR-based technique a preferable choice among other optical detection techniques [15].

The application of 2D materials for sensitivity enhancement in SPR sensors have been reported earlier [16,17,18,19]. In continuation, few layer 2D Ti3C2Tx MXene in SPR-based sensors for sensitivity enhancement was reported by Wu et al. [11]. Significantly higher sensitivity values than conventional Au-based SPR sensor were reported at operating wavelengths of 633 and 532 nm. MXene-based ultrasensitive SPR biosensor has been reported recently for the detection of carcinoembryonic antigen with a detection limit of 0.07 fM [12]. Further, Xu et al. reported sensitivity enhancement using transition metal dichalcogenide (TMD) and Ti3C2Tx MXene (with Au interlayer) layer with a high sensitivity value of 198°/RIU at 633 nm (analyte refractive index \(\sim \) 1.33) [13]. The effect of multilayer on the sensitivity was also discussed. However, the width of SPR curve (i.e. FWHM—full width at half maximum) which gives crucial information about accuracy of detection and the optimization of metal layer thickness for minimum reflectance at resonance were not addressed. Moreover, there is need to explore the combination of graphene with 2D Ti3C2Tx MXene in SPR-based sensor for a precise and high sensitive detection of biosamples.

The combination of graphene and Ti3C2Tx MXene is the desirable one owing to their advanced properties. The electrical conductivity of graphene is higher than that of TMDs, which expedites the charge transfer among the layers. Furthermore, the graphene flakes can improve the mechanical strength of Ti3C2Tx MXene after the formation of 2D heterostructure. Aïssa et al. reported the high conductivity property of 2D Ti2CTx MXene/graphene sandwich-like composite [20] which is the motivation behind this work. Recently, the hybrid combination of Ti2CTx MXene with reduced graphene oxide (rGO) has been reported for application in Li-ion storage [21]. Further, the hybrid film possesses several advantages such as, excellent cycling stability, rate performance and reversible capacity (700 mAh/g at 0.1 A/g). Zhao et al., proposed fabrication of 2D MXene/graphene heterostructure using Spray-assisted layer-by-layer (LbL) process [22]. Nevertheless, no prior works have been reported based on the application of graphene–MXene heterojunction/heterostructure in SPR-based sensors for performance enhancement. Previously, the incorporation of 2D materials with graphene layers has provided a path for sensitivity enhancement [17, 23]. Field enhancement at the interface [24] and increased surface adsorption in case of SPR-based sensors are the two main advantages of having heterostructure as analyte interacting layer. Thus, there are a lot of possibilities in exploring the sensing capabilities of graphene/MXene heterostructure.

Sensitivity enhancement of SPR-based sensors using graphene–Ti3C2Tx MXene hybrid nanostructure is explored in this work based on the optimised metal thickness at two specific wavelengths (532 nm and 633 nm). These wavelengths are commonly used in the visible region for SPR-based sensing application. The optimization of metal thickness is performed to achieve minimum reflectance at resonance. In addition, the performance of the proposed sensor structure (SiO2/Ag/ graphene/Ti3C2Tx MXene) is also analysed in terms of detection accuracy (D.A). Further, the sensitivity enhancement with increasing the number of Ti3C2Tx MXene monolayers is also demonstrated.

2 Sensor’s configuration and theoretical insights

The Kretschmann configuration-based sensor structure is shown in Fig. 1. During experimental realisation of such configurations, the main required components are laser source with polarizer, substrate/prism deposited with multi-layered structure and photodetector or charge coupled camera (CCD). The multi-layered structure is generally mounted on a rotary stage. Silica glass prism, i.e. SiO2 (first layer) is considered as the coupling material. The second layer is SPR active metal silver (Ag). The third layer is graphene monolayer which is covered by Ti3C2Tx MXene (fourth layer). This heterojunction (monolayer graphene and Ti3C2Tx MXene) will also prevent Ag from possible oxidation concerns. The sensing layer is considered as the last layer.

Fig. 1
figure 1

Schematic of proposed Kretschmann configuration-based 5-layered SPR sensor using graphene monolayer–Ti3C2Tx MXene. SPR curve experiences a narrow dip at θSPR when SPs are coupled with incident TM (transverse magnetic) light

In this work, the chosen dielectric constant values of different materials at λ = 633 nm and 532 nm are shown in Table 1. The reflectance (R) analysis is based on the variation of incident angle (i.e. angular interrogation method) at a fixed wavelength (here, λ = 633 nm or λ = 532 nm) of transverse magnetic (TM/ p-polarised) incident light. The numerical calculation of R is based the on N-layer transfer matrix method (TMM) [28]. Following equation represents coupling of incident light and SPs at metal–dielectric interface [14]:

$$ \frac{\omega }{c}n_p \sin \theta_{{\text{SPR}}} = {\text{real}}\left( {\frac{\omega }{c}\sqrt {\frac{ \in_m \in_s }{{ \in_m + \in_s }}} } \right). $$
(1)
Table 1 Dielectric constant values of layers at two different wavelengths used in this study

Here, np is RI of the coupling prism, ω is the angular frequency of the incident light, c is the velocity of light in vacuum, εm and εs are the dielectric constant of the metal and sensing (analyte) layer, respectively. SPR curve experiences a narrow dip at a particular incident angle which is termed as the resonance angle (θSPR). A small change in εs value will lead towards the shifting in angular position of SPR dip.

3 Results and discussion

3.1 Metal layer thickness optimization

The minimum possible value of reflectance (Rmin) at resonance can only be achieved by proper optimization of Ag layer thickness (tAg). This optimization plays a crucial role in strengthening of evanescent field. For optimization of tAg, ns = 1.333 is taken into account for conventional Ag-based SPR sensor (without 2D material layer) and proposed structure. In case of conventional structure, Rmin value of 1.5492 \(\times \) 10–5 is calculated for tAg = 55 nm as shown in Fig. 2a. The optimised tAg value for proposed sensor is 41 nm at which Rmin = 4.9628 \(\times \) 10–4 as shown in Fig. 2b. These optimised tAg values are used in further numerical calculations.

Fig. 2
figure 2

2D plot variation of R with tAg (in nm) and incident angle at λ = 633 nm with analyte RI = 1.333 for a conventional SPR-based sensor (Ag over prism) b proposed sensor configuration using monolayer Ti3C2Tx MXene over monolayer graphene.

Meanwhile, the R curves for conventional (tAg = 55 nm) and proposed sensor (tAg = 41 nm) are shown in Fig. 3 considering two different values of ns (1.333 and 1.334). It is evident that ΔθSPR (small change in the angular position of θSPR) for conventional and proposed sensor configurations are 0.167° (Fig. 3a) and 0.171° (Fig. 3b), respectively, for a small change in ns value (i.e. Δns = 0.001). The sensitivity (S) which is an important performance parameter can be defined as S = ΔθSPR/Δns, generally expressed in deg./RIU. Thus, it can be inferred that the proposed sensor is able to provide higher sensitivity (0.171°/0.001 = 171°/RIU) as compared with that of conventional scheme (0.167°/0.001 = 167°/RIU). Moreover, Ag is the analyte interacting layer in conventional structure which may undergo some deterioration/degradation affecting the sensor’s performance [29]. In the proposed structure, graphene–Ti3C2Tx MXene heterojunction will act as a protective layer for Ag.

Fig. 3
figure 3

Variation of reflectance with incident angle at λ = 633 nm for two different analyte RI in case of a conventional SPR-based sensor (Ag over prism) b proposed sensor configuration

The variation of reflectance with incident angle for a range of analyte RI (1.33–1.36) is shown in Fig. 4a. The θSPR values of 74.786°, 76.530°, 78.50° and 80.821° are obtained for analyte RI values of 1.33, 1.34, 1.35 and 1.36, respectively. The shift in SPR curves for different analyte RI can be explained on the basis of Eq. (1). Further, to clearly visualise the variation of θSPR with analyte RI, Fig. 4b shows the 2D plot of the reflectance variation with analyte RI and incident angle. The occurrence of Rmin will provide information about the angular position of θSPR. It is evident that θSPR increases when the analyte RI is increased.

Fig. 4
figure 4

Variation of reflectance with incident angle different analyte RI values (1.33–1.36) for proposed sensor at λ = 633 nm a SPR curves b 2D plot of the variation showing resonance angle (θSPR) shift on changing the analyte RI

To depict the performance of the sensor at λ = 633 nm, the variations of sensitivity and detection accuracy (D.A.) with analyte RI is shown in Fig. 5a. The D.A. can be defined as the reciprocal of FWHM (i.e. D.A. = 1/FWHM) [30]. Considering reference sample RI of 1.33, the sensitivity value increases from 169.60°/RIU to 201.166°/RIU for analyte RI of 1.335 and 1.360, respectively. However, the D.A. value decreases from 0.239 deg−1 to 0.185 deg−1 on increasing analyte RI from 1.335 to 1.360. Evidently, there is a trade-off between sensitivity and D.A. Thus, analyte RI range can be selected based on the requirements of high sensitivity and affordable D.A. value. Moreover, the effect of number of layers (L) of Ti3C2Tx MXene over graphene on sensitivity is shown in Fig. 5b. For ns = 1.33 and Δns = 0.005, the sensitivity increases form 169.60°/RIU (‘L = 1’) to 196.86°/RIU (‘L = 4’) which further decreases to 171.30°/RIU (‘L = 6’). In addition, for ns = 1.34 and Δns = 0.005, a high sensitivity of 214.20 o/RIU is calculated at ‘L = 3’ which decreases to 145.00°/RIU (‘L = 6’). This decrease in sensitivity on increasing ‘L’ has been demonstrated earlier by Wu et al. [11] based on the movement of reflectance curve towards larger angle. This is due to the limitation in the range of incident angle from 0° to 90°. Thus, it can be interpreted that ‘L = 4’ at λ = 633 nm can be opted when the analyte RI is in the vicinity of 1.33 and 1.34.

Fig. 5
figure 5

a Variation of sensitivity and detection accuracy with analyte RI values (1.33–1.36) for proposed monolayer graphene–Ti3C2Tx MXene sensor at λ = 633 nm b Sensitivity variation with number of MXene layer (L) over graphene monolayer for two different analyte RI values (1.33 and 1.34) and Δns = 0.005 at λ = 633 nm

The above discussion is meant for application of proposed SPR sensor at λ = 633 nm using monolayer graphene–Ti3C2Tx MXene nanostructure. However, the analysis is also performed at commonly used wavelength of 532 nm in the visible region for SPR-based sensing application. Initially, the tAg value is optimised in view of Rmin at resonance condition. Wavelength-dependent dielectric properties of the layers play an important role in optimising the Ag layer thickness at a particular wavelength. Considering ns = 1.32, Rmin = 2.2957 \(\times \) 10–4 is obtained at tAg = 37 nm (λ = 532 nm). Figure 6 a shows the variation of SPR curves with incident angle for different ns (optimised tAg = 37 nm). The θSPR values for discrete ns are 79.0° (ns = 1.32), 80.156° (ns = 1.325), 81.418° (ns = 1.33) and 82.803o (ns = 1.335). Thus, for a small Δns (1.335–1.32 = 0.015), the corresponding shift in angular position of resonance (i.e. ΔθSPR) is 3.803°. A significantly high average sensitivity of 253.533°/RIU (3.803°/0.015) along with a reasonable average FWHM value of 8.440° is calculated for the analyte RI in the vicinity of 1.32 and 1.33 in case of proposed SiO2–Ag–graphene–Ti3C2Tx MXene-based SPR sensor. In this context, the variation of ΔθSPR with analyte RI (i.e. ns) is shown in Fig. 6b. Further, when ns = 1.33 and Δns = 0.005, a high sensitivity value of 277°/RIU (1.385°/0.005) is calculated. It should be noted that increasing ns beyond 1.34 and (or) increasing ‘L’ will cause shift in the reflectance curve towards a greater angle (outside the range 0° to 90°). Thus, the monolayer MXene (L = 1) over graphene is a preferable choice at 532 nm. Table 2 shows the sensitivity comparison among recently reported works and proposed work based on the SPR sensors utilising 2D Ti3C2Tx MXene for sensitivity enhancement. Generally, a larger SPR shift is achieved in case of Au-based structure than that of Ag-based structure. In addition, the low RI substrate will be beneficial for achieving high sensitivity (due to large change in angle of reflection) which can be explained on the basis of Snell's law as reported in the previous study [31]. The proposed structure has the advantage of high sensitivity along with a reasonable detection accuracy.

Fig. 6
figure 6

a Variation of reflectance with incident angle different analyte RI values (1.320–1.335) for proposed sensor at λ = 532 nm (the monolayer graphene and monolayer Ti3C2Tx MXene are used) b variation of ΔθSPR with analyte refractive index at λ = 532 nm

Table 2 Sensitivity comparison among recently reported works utilising 2D Ti3C2Tx MXene

4 Conclusion

SPR-based biosensor utilising graphene–Ti3C2Tx MXene hybrid nanostructure is proposed in this work. The theoretical analysis is initiated with the optimization of Ag layer thickness. A sensitivity value of 169.60°/RIU (analyte RI \(\sim \) 1.33) is obtained for proposed sensor utilising monolayer graphene–Ti3C2Tx MXene at incident light wavelength of 633 nm. Further, it is demonstrated that increasing Ti3C2Tx MXene layers (L) over graphene enhances the sensitivity. On increasing the number of Ti3C2Tx MXene layers, high sensitivity values of 196.86°/RIU (L = 4) and 214.20°/RIU are (L = 3) obtained at 633 nm for analyte RI values of 1.33 (Δns = 0.005) and 1.34 (Δns = 0.005), respectively. In addition, an average sensitivity and FWHM values of 253.533°/RIU and, 8.440°, respectively, are calculated at λ = 532 nm for analyte RI in the vicinity of 1.32. Thus, the proposed sensor configuration (SiO2/Ag/graphene/Ti3C2Tx MXene) is able to provide a high sensitivity with reasonable detection accuracy.