Abstract
Background
Anastomotic leakage is a serious complication in laparoscopic colorectal surgeries. To resolve this problem, a new stapling technology (Tri-staple) is developed. In this study, we aim to compare the short-term outcomes of Tri-staple versus Universal staple in laparoscopic anterior resection of rectal and distal sigmoid colonic cancer.
Methods
A total of 446 patients were admitted to our hospital and received laparoscopic anterior resection for rectal and distal sigmoid colonic cancer between January 2016 and December 2020. Among them, Tri-staples were used in 202 patients, and the Universal staples were used in 244 patients. Propensity score matching was performed, followed by a comparison between the two groups (Tri-staple vs. Universal staple) in the incidences of anastomotic leakage, bleeding, and reoperation.
Results
In total, 270 patients were included in this retrospective cohort study by the propensity score matching, with each group having 135 patients. Tri-staple group had a significant lower incidence of anastomotic leakage compared with the Universal staple group (4.44% vs. 11.11%, P < 0.05). The reoperation rate was also lower in Tri-staple group than the Universal staple group (3.70% vs. 8.15%, P < 0.05). The anastomotic bleeding rates, average postoperative hospital stay, average drain indwelling period, and average fasting period had no statistical differences between the two groups.
Conclusion
The usage of Tri-staple in laparoscopic anterior resection of rectal and distal sigmoid colonic cancer is associated with lower postoperative complications compared with Universal staple. Future high-quality randomized controlled trials are needed to confirm our findings.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Laparoscopic anterior resection is a common procedure used for the treatment of rectal and distal sigmoid colonic cancer. However, this procedure is associated with postoperative complications, typically anastomotic leakage—a complication that may lead to severe and life-threatening conditions, require reoperation, and prolong hospital stay [1, 2]. Hültl [3] first introduced surgical staple in 1908. Since then, staples had been used for creating anastomoses. In the era of minimally invasive surgery, surgical staples become particularly relevant. Although recent years have witnessed a wide range of research on stapling technology, the optimal anastomotic devices and techniques remain controversial [4,5,6,7]. Since 2010, our center has been using the Universal staple (Endo GIA Universal straight reload, blue, Covidien, Mansfield, MA) for bowel closure and dissection in laparoscopic rectal and distal sigmoid colonic cancer surgery, and until 2015, the Tri-staple (Endo GIA articulating reload with Tri-staple technology, purple, Covidien, Mansfield, MA) was officially used in our clinical practice. The Tri-staple is a novel endoscopic linear staple characterized by its stepped cartridge faces and varied height staples [8] (Fig. 1a). This technology is designed to improve staple security across a broad range of tissues while preserving the blood supply of the stump [9,10,11,12]. These outstanding features might help the surgeons to reduce incidences of postoperative complications such as anastomotic leakage and improve the short-term outcomes. In this study, we aim to retrospectively compared the short-term outcomes of Tri-staple vs. Universal staple (Fig. 1b) in laparoscopic anterior resection of rectal and distal sigmoid colonic cancer.
Materials and methods
Patient selection
A total of 690 patients were admitted to Shanghai Changzheng hospital and received radical resection for rectal and distal sigmoid colonic cancer between January 2016 and December 2020. Exclusion criteria: A patient should be rendered ineligible for the study if he/she suffered from any anorectal diseases or malignant tumors related to other factors than laparoscopic anterior resection, or the patient experienced symptoms of severe organ failure, or received any treatment that might bring bias to results of the study [13]. Among the 690 patients, 114 patients received laparoscopic anterior resection without using the aforementioned two kinds of staples; 45 underwent Hartmann’s procedure; 50 underwent Miles’ procedure; 35 patients underwent complete or partial intersphincteric resection (ISR) procedure. The remaining 446 patients received laparoscopic anterior resection of rectal and distal sigmoid colonic cancer using either Tri-staple (purple staple, n = 244) or Universal staple (blue staple, n = 202). In light of the diagnostic criteria of rectal or distal sigmoid colonic cancer set out by the National Comprehensive Cancer Network (NCCN), all research subjects showed signs and symptoms of rectal or distal sigmoid colonic cancer, and definite diagnoses were established on the basis of preoperative colonoscopic biopsy and histology [14]. We excluded cases involving (1) other serious systemic disorders; (2) prophylactic terminal ileostomy; (3) Hartmann surgery; (4) emergency cases. In the propensity score matching, the following factors were taken into consideration: age, sex, blood serum biochemical indicators, coexisting diseases, pathological stage, number of staples for closure, number of lymph node dissection, TNM stage, distance from anal verge, neoadjuvant radiochemotherapy, and dwelling anal tubing. Intergroup comparisons were conducted before and after propensity score matching. The study was approved by the institutional review board and was reported following the STROBE guideline (Supplement Table 1).
Surgical technique
Four well-trained surgeons (surgical experience ≥ 10 y) performed the surgery. All procedures were carried out according to the guidelines for radical resection of colorectal cancer developed by the European Society for Medical Oncology (ESMO). In brief, a five-port laparoscopic approach was performed [15]. Carbon dioxide pressure for pneumoperitoneum was maintained around 12 mmHg during the procedure. The sigmoid colon was mobilized using a medial approach. The roots of the inferior mesenteric vessels were ligated and cut. The left Toldt’s space was fully dissected to mobilize the sigmoid colon. The mesorectum was mobilized as needed. The distal line was determined and divided by endoscopic staples (Tri-staple or Universal staple) (Fig. 2a and b). The specimen was extracted through a 4 cm transverse mini-laparotomy incision on the left lower quadrant. An intra-abdominal end-to-end anastomosis was performed using a circular stapler (Premium Plus CEEA, Covidien, Mansfield, MA) under laparoscope (Fig. 2c). All patients were indwelling abdominal drains.
Short-term outcomes
Primary outcomes include anastomotic leakage and anastomotic bleeding. In this study, the definition of anastomotic leakage developed by the International Study Group on Rectal Cancer (ISREC) was used as reference [16]. Secondary outcomes include reoperation rate and postoperative hospital stay. Other short-term outcomes were also collected and analyzed.
Post hoc power analysis
Since some specific factors may contribute to the choice of surgical staples, we designed this post hoc power analysis. The outcomes including tumor location, body mass index (BMI), age, diabetes, surgeon's preferences, and medical insurance were collected and analyzed.
Statistical analysis
The demographic data, operative data, and postoperative outcomes of the patients were retrieved. The stapling devices used were ascertained. Operative outcomes were analyzed in accordance with the type of stapling device used, either Universal staple or Triple-staple. A propensity score was generated for each of these cases, taking into account the following: age, sex, serum biochemical indicators, number of staples for closure, number of lymph node dissection, TNM stage, pathological stage, distance from anal verge, coexisting diseases, neoadjuvant therapy, and dwelling anal tubing. Comparisons were made before and after matching of the patients according to their propensity scores.
The primary end points were anastomotic complications, namely anastomotic leakage and anastomotic bleeding. Anastomotic leakage was defined according to the well accepted guidelines of the 1991 United Kingdom Surgical Infection Study Group as “leak of luminal content from a surgical join between two hollow viscera”. The secondary end points were reoperation rate, average postoperative hospital stay, average drain indwelling period and average fasting period.
SPSS 23.00 (IBM, USA) was used for statistical analysis. The Chi-squared test and the Fisher’s exact test were employed in the comparison of classification variables; the Shapiro–Wilk test was applied to examine normal distributions of continuous variables; the Mann–Whitney U test was used on non-normal distributions. Only binary comparisons were involved in this study where P < 0.05 indicated statistical significance. Because categorical data, which included missing data, were created with “missing” categories, participants with “missing” information were included in the analysis to maximize the statistical power.
We conducted a series of sensitivity analyses to evaluate the robustness of the findings of the study and how our conclusions can be affected by applying various association inference models. We added two association inference models in the original cohort and the weighted cohort in the sensitivity analysis. The calculated effect sizes and p values from all these models were reported and compared. All results are reported according to the STROBE statement.
Results
Cohorts and baseline feature comparison
Follow-up time of all patients in the study was 15–35 days. One hundred thirty-five patients of each group were selected for intergroup comparison following the propensity score matching (Fig. 3). Before propensity score matching, the two groups were not comparable in terms of diabetes, neoadjuvant therapy, dwelling anal tubing. After the propensity score matching, patients of the two groups became broadly comparable in terms of age, sex, serum biochemical indicators, number of lymph node dissection, TNM stage, pathological stage, distance from anal verge, coexisting diseases, neoadjuvant therapy, and indwelling anal tubing (P > 0.05) (Table 1).
Surgical outcomes
The incidence of anastomotic leakage was significantly lower in Tri-staple group compared with Universal staple group (4.44% vs. 11.11%, P < 0.05). The anastomotic bleeding rates were comparable between the two groups (2.22% vs. 2.96%, P = 0.534). Whether reoperations were performed mostly depends on the patient's general vital signs and toxemia. The reoperation rate of the Tri-staple group was significantly lower than that of the Universal staple group (3.70% vs. 8.15%, P < 0.05). All Grade C anastomotic leakages were treated with reoperations. The anastomotic bleeding rates, average postoperative hospital stay, drain indwelling period, and fasting period had no statistical differences between the two groups (Table 2).
Post hoc power analysis
The ratios of BMI ≥ 30 and diabetes in Tri-staple group were higher than those in Universal staple group. Surgeon's preferences had an impact on the choice of surgical staples. Tumor location, age, and medical insurance were comparable between the two groups (Table 3).
Discussion
Minimally invasive colorectal surgery has gained popularity worldwide due to its similar safety, resection margins, and completeness of resection, and improved recovery compared with that of open surgery [17, 18]. The reconstruction is a critical step in such a procedure and largely replies on the surgical staplers. Complications related to stapled resection and anastomoses are mainly anastomostic leakage and bleeding [19]. We hypothesized that Tri-staple technology reduced the risk of anastomostic leakage and bleeding in laparoscopic anterior resection of rectal and distal sigmoid colonic cancer. Our results showed Tri-staple group had a significant lower incidence of leakage compared with the Universal staple group (4.44% vs. 11.11%, P < 0.05). The reoperation rate was also lower in Tri-staple group than the Universal staple group (3.70% vs. 8.15%, P < 0.05). The anastomotic bleeding rates and postoperative hospital stay were comparable between the 2 groups.
The Tri-staple is a novel linear staple with outstanding performance across a broad range of tissues [9,10,11,12]. According to the information from the manufacturer, with its stepped cartridge face, the Tri-staple delivers graduated compression, can result in decreased stress in tissues compared to single height staples [20]. In animal study using micro-computed tomography methodology, graduated-height staples had significantly higher micro-perfusion volume than single height staples, which likely could translate into a downstream benefit on wound healing and clinical outcomes [21]. Also, the improved design of the stronger fixed anvil and I-beam incorporated into the Tri-staple results in improved burst pressure strength, consistent hemostatic performance, and improved tissue retention during manipulation and transection [22].
The main limitation of this study was its retrospective nature. The choice of linear stapler mainly depends on surgeon preference and the supply of instruments. The chief surgeons in this study were four senior surgeons in our center who have been engaged in laparoscopic colorectal cancer surgery for more than 10 years. We increased a post hoc power analysis, and the results showed that the ratios of BMI ≥ 30 and diabetes in Tri-staple group were higher than those in Universal staple group; surgeon's preferences had an impact on the choice of surgical staples; tumor location, age, and medical insurance were comparable between the two groups. In the presence of risk factors for anastomotic leakages, such as obesity and diabetes, we were indeed more inclined to choose Tri-staple. Although all patients used the same manufacturer's EEA and we performed propensity score matching, the exact site of anastomotic leakages cannot be confirmed to be from the linear staple line or from the EEA. Despite robust matching of potential confounding variables, bias could still exist, and the results should be interpreted cautiously. In this study, all patients with unexplainable toxemia with or without abdominal pain after operation were clinically diagnosed as anastomotic leakages, which may explain why the leak rate was higher than many studies.
No study has been published to date with regard to the effect of Tri-staple technology on the clinical outcome in laparoscopic anterior resection of rectal and distal sigmoid colonic cancer. The present study filled the gap and showed lower rates of anastomotic leakage and reoperation in Tri-staple group compared with the Universal staple group.
Based on our findings and experience, we recommend the usage of Tri-staple in laparoscopic anterior resection of rectal and distal sigmoid colonic cancer as a more effective tool with better short-term outcomes compared with Universal staple. Future high-quality randomized controlled trials are needed to confirm our findings.
References
Nakayama S, Hasegawa S, Hida K et al (2015) Obtaining secure stapling of a double stapling anastomosis. J Surg Res 193(2):652–657
Elariny H, González H, Wang B (2005) Tissue thickness of human stomach measured on excised gastric specimens from obese patients. Surg Technol Int 14(1):119–124
Kawada K, Hasegawa S, Hida K et al (2014) Risk factors for anastomotic leakage after laparoscopic low anterior resection with DST anastomosis. Surg Endosc 28(10):2988–2995
Hirano Y, Hattori M, Douden K et al (2012) Single-incision plus one port laparoscopic anterior resection for rectal cancer as a reduced port surgery. Scand J Surg 101(4):283–286
Kwaan MR, Al-Refaie WB, Parsons HM et al (2013) Are right-sided colectomy outcomes different from left-sided colectomy outcomes? Study of patients with colon cancer in the ACS NSQIP database. JAMA Surg 148(6):504–510
Hammond J, Lim S, Wan Y et al (2014) The burden of gastrointestinal anastomotic leaks: an evaluation of clinical and economic outcomes. J Gastrointest Surg 18(6):1176–1185
Ho YH, Ashour MA (2010) Techniques for colorectal anastomosis. World J Gastroenterol 16(13):1610–1621
Nagahisa Y, Morikawa A, Kato T et al (2018) Feasibility of endo GIA™ reinforced reload with Tri-staple™ technology for delta-shaped anastomosis. Asian J Surg 41(5):448–453
Man-I M, Suda K, Kikuchi K et al (2015) Totally intracorporeal delta-shaped B-I anastomos is following laparoscopic distal gastrectomy using the Tri-staple™ reloads on the manual ultra handle: a prospective cohort study with historical controls. Surg Endosc 29(11):3304–3312
Hansen H (2011) Applications of Tri-staple technology in minimally invasive thoracic surgery. Gen Surg News 38(3):22–23
Scuderi V, Troisi RI (2014) Tissue management with tri-staple technology in major and minor laparoscopic liver resections. Int Surg 99(5):606–611
van Vugt JL, Tegels JJ, Derikx JP et al (2015) First experiences with the radial reload with tri-staple™ technology in low rectal surgery. Int J Surg 14:23–27
Gustafsson P, Jestin P, Gunnarsson U et al (2015) Higher frequency of anastomotic leakage with stapled compared to handsewn ileocolic anastomosis in a large population-based study. World J Surg 39(7):1834–1839. https://doi.org/10.1007/s00268-015-2996-6
NCCN org. (2018) NCCN clinical practice guidelines in oncology: rectal cancer, version 2.2018; 14
Zhou H, Ruan C, Sun Y et al (2015) Nerve-guided laparoscopic total mesorectal excision for distal rectal cancer. Ann Surg Oncol 22(2):550–551
Rahbari NN, Weitz J, Hohenberger W et al (2010) Definition and grading of anastomotic leakage following anterior resection of the rectum: a proposal by the international study group of rectal cancer. Surgery 147(3):339–351
Bonjer HJ, Deijen CL, Abis GA et al (2015) A randomized trial of laparoscopic versus open surgery for rectal cancer. N Engl J Med 372(14):1324–1332
Stevenson ARL, Solomon MJ, Brown CSB et al (2019) Disease-free survival and local recurrence after laparoscopic-assisted resection or open resection for rectal cancer: the Australasian laparoscopic cancer of the rectum randomized clinical trial. Ann Surg 269(4):596–602
Shigeta K, Okabayashi K, Baba H et al (2016) A meta-analysis of the use of a transanal drainage tube to prevent anastomotic leakage after anterior resection by double-stapling technique for rectal cancer. Surg Endosc 30(2):543–550
Nováček V, Tran TN, Klinge U et al (2012) Finite element modeling of stapled colorectal end-to-end anastomosis: advantages of variable height stapler design. J Biomech 45(15):2693–2697
Eschbach M, Sindberg GM, Godek ML et al (2018) Micro-CT imaging as a method for comparing perfusion in graduated-height and single-height surgical staple lines. Med Dev (Auckl) 11:267–273
Hasegawa S, Nakayama S, Hida K et al (2015) Effect of tri-staple technology and slow firing on secure stapling using an endoscopic linear stapler. Dig Surg 32(5):353–360
Funding
This work was supported by the National Key R&D Program of China (No. 2019YFA0110601).
Author information
Authors and Affiliations
Contributions
QS and AW wrote the manuscript. SW, YH, HL, ZH, HZ collected and analyzed the data. ZH and HZ revised the manuscript critically. All authors read and approved the final manuscript.
Corresponding authors
Ethics declarations
Conflict of interest
All authors have no conflicts of interest or financial ties to disclose.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Sun, Q., Wang, A., Wei, S. et al. Short-Term Outcomes of Tri-Staple Versus Universal Staple in Laparoscopic Anterior Resection of Rectal and Distal Sigmoid Colonic Cancer: A Matched-Pair Analysis. World J Surg 46, 2817–2824 (2022). https://doi.org/10.1007/s00268-022-06704-9
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00268-022-06704-9