Background: The purpose of this study was to make a quantitative comparison between conventional and harmonic power Doppler (PD) ultrasound (US) in depicting vascularity of hepatocellular carcinoma (HCC).
Methods: Ten nodular HCCs in 10 patients were prospectively examined using a 2–4-MHz convex transducer and a standardized examination protocol. Serial US images were obtained before and 20, 30, 40, 50, 60, 90, 120, 150, 180, 240, and 300 s after intravenous injection of 2 g of contrast agent using conventional and harmonic PD US. The percentage of area with Doppler signal within each HCC nodule (%PDA) was calculated in each image with a PC-based image analysis program, and the results with both US techniques were compared.
Results: In the majority of cases, %PDA was greater on conventional PD US than on harmonic PD US. Mean %PDA of 10 HCCs was significantly higher on conventional PD US than on harmonic PD US except at 20 s after injection. The highest values of mean %PDA were 34.9% in conventional PD US and 19.5% in harmonic PD US at 60 s after injection.
Conclusion: Area with PD signals within the HCC is smaller and the duration of effective enhancement is shorter in harmonic PD US than in conventional PD US.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Author information
Authors and Affiliations
Additional information
Received: 28 February 2000/Revision accepted: 12 July 2000
Rights and permissions
About this article
Cite this article
Park, S., Kim, T., Lee, K. et al. Quantitative comparison of tumor vascularity of hepatocellular carcinoma after intravenous contrast agent: conventional versus harmonic power Doppler US. Abdom Imaging 26, 178–183 (2001). https://doi.org/10.1007/s002610000129
Published:
Issue Date:
DOI: https://doi.org/10.1007/s002610000129