Several studies have reported on the use of high-resolution 90Y PET/CT scans in the evaluation of the biodistribution of 90Y-labelled glass or resin based microspheres after radioembolisation of malignant liver lesions [1–4]. PET/MR is an emerging technology providing particularly high soft tissue contrast and no inherent radiation exposure. A 67-year-old man with multifocal unresectable hepatocellular carcinoma was referred for selective internal radiation therapy (SIRT). The pretreatment management consisted of angio-CT of the liver, embolisation of the right gastric and gastroduodenal arteries followed by 99mTc-MAA SPECT/CT. Two weeks later, 4.3 GBq of 90Y-labelled TheraSpheres® (MDS Nordion, Kanata, Canada) were administered in a single bolus into the right liver lobe. Subsequently, the patient underwent integrated 90Y bremsstrahlung SPECT/CT on a Symbia T6 hybrid scanner (Siemens, Erlangen, Germany) equipped with a medium-energy collimator. The energy peak was set at 90 keV with a 30% window. SPECT data were reconstructed using the FLASH 3-D algorithm (4 iterations, 8 subsets). PET/MR was obtained on a Philips Gemini TF PET/MR. PET scanning (one bed position centred on the liver) lasted for 30 min; the MR protocol consisted of a 3-D T1 FFE sequence (TE = 2.3 ms, TR = 4.1 ms, voxel size = 3 × 3 × 6 mm) for anatomical correlation and attenuation correction, and axial as well as coronal T2 HASTE sequences (TE = 136 ms, TR = 2,351 ms, voxel size = 1.2 × 1 × 5mm). The PET data were reconstructed using a 3-D line-of-response time-of-flight (TOF) blob-based algorithm (3 iterations, 33 subsets) with a voxel size of 4 × 4×4 mm3. MR allowed better lesion visualisation than contrast-enhanced CT (white arrows and arrowheads); PET/MR provided sharper lesion to background contrast and discrimination than SPECT/CT (black arrows).
References
Gates VL, Esmail AA, Marshall K, Spies S, Salem R. Internal pair production of 90Y permits hepatic localization of microspheres using routine PET: proof of concept. J Nucl Med 2010;52:72–6.
Lhommel R, Goffette P, Van den Eynde M, Jamar F, Pauwels S, Bilbao JI, et al. Yttrium-90 TOF PET scan demonstrates high-resolution biodistribution after liver SIRT. Eur J Nucl Med Mol Imaging 2009;36:1696.
Lhommel R, van Elmbt L, Goffette P, Van den Eynde M, Jamar F, Pauwels S, et al. Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-Spheres. Eur J Nucl Med Mol Imaging 2010;37:1654–62.
Werner MK, Brechtel K, Beyer T, Dittmann H, Pfannenberg C, Kupferschläger J. PET/CT for the assessment and quantification of (90)Y biodistribution after selective internal radiotherapy (SIRT) of liver metastases. Eur J Nucl Med Mol Imaging 2010;37:407–8.
Conflicts of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Wissmeyer, M., Heinzer, S., Majno, P. et al. 90Y Time-of-flight PET/MR on a hybrid scanner following liver radioembolisation (SIRT). Eur J Nucl Med Mol Imaging 38, 1744–1745 (2011). https://doi.org/10.1007/s00259-011-1792-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00259-011-1792-2