Introduction

Urolithiasis is a common disease, affecting about 12 % of men and 6 % of women during their lives, with a prevalence that is progressively increasing during the years and with high recurrence rate [15]. Urinary stones chemical composition is quite variable and comprehends, in the majority of the cases, calcium oxalates (monohydrate or dihydrate) or phosphates (brushite or apatite), uric acid, and cysteine [6]; moreover, mixed calculi may be often observed. Unenhanced CT is, nowadays, the imaging modality of choice in the evaluation of symptomatic urolithiasis, because of its ability of providing, by means of a single, rapid and reproducible examination, information about stone location and size, presence and degree of urinary obstruction, presence of complications, and eventual differential diagnoses [712].

Stone composition is a parameter that should be known to tailor the best therapeutic approach for each patient affected by symptomatic urolithiasis, since uric acid stones can be successfully managed by means of urine alkalinization that facilitates dissolution, struvite calculi are sensitive to extracorporeal shock-wave lithotripsy (ESWL), and calcium oxalate and cysteine stones often require percutaneous nephrolithotripsy or ureteroscopy [13]. Blood tests, urine sediment analysis, and review of patient’s clinical history are often insufficient for determining the true nature of a calculus. In this setting, CT may represent a useful tool for stone composition characterization, being attenuation values correlated with stone composition [1417]. However, no definite cut-off values have been provided in the literature for differentiating the various stone phenotypes, and a quite large variability in attenuation values has been reported by comparing different CT scanners [18, 19].

Since its introduction in the clinical practice, dual-energy CT (DECT) has emerged as an extremely accurate technique for determining urinary stones composition and several works have already demonstrated its high accuracy, both in vitro and in vivo [2029]. Nevertheless, to our knowledge, there are no studies that have directly compared in vivo accuracy of DECT with that of single-energy CT in urinary stones characterisation.

Therefore, the aim of our study was to compare the accuracy in vivo of 100/Sn140 kV dual-energy CT with that of 120 kV single-energy CT in the determination of urinary stones composition by means of an automated commercially available software.

Materials and methods

Patient population

This was a retrospective study approved by our Institutional Review Board; need for informed consent was waived. We considered for the inclusion into our study 215 consecutive patients that underwent CT scan on the second-generation dual-source CT scanner in our institution in the clinical suspicion of urolithiasis during the period October 2012–April 2014.

Inclusion criteria were: presence of renal stones at CT (97/215 patients) and stones extraction or expulsion within 1 month from the CT examination with subsequent stone analysis by means of infrared spectroscopy (32/97).

Exclusion criteria were: incomplete CT examination (1/32 patients) and poor image quality, because of motion artefacts (1/32 patients). Therefore, our study population included 30 patients, 18 males and 12 females, with a mean age of 56 years (range 34–86).

CT protocol

All the examinations were performed on a second-generation dual-Source CT scanner (Somatom Definition Flash; Siemens Healthcare, Forchheim, Germany) equipped with a tin filter on the high-energy tube (Sn) for improved separation between the high- and low-energy spectra, according to a protocol that included a preliminary 120 kV single-energy low-dose scan of the abdomen, from the upper renal poles to the pelvic floor, followed by an additional 100/Sn140 kV simultaneous dual-energy scan limited to the volume(s) where urinary stones were eventually detected (Table 1). All the examinations were performed with the patient lying supine on the table, with the arms bended over his head whenever possible.

Table 1 CT scanning protocol in the suspicion of urolithiasis

Image analysis

CT images were evaluated on a workstation (Syngo.Via, Siemens, Erlangen, Germany) by two radiologists with 5 and 15 years of experience in urogenital radiology, respectively, both with 4 years of experience in DECT, using multi-planar reconstructions.

First of all, the number of urinary stones, their location (urinary calices, pelvis, ureter, or bladder) and the presence of ureteral catheters was recorded by the two radiologists in consensus on the 120 kV images. Then, stone attenuation values (mean and standard deviation, in HU) at 120 kV were measured by the two radiologists independently on 1 mm-thick multi-planar reconstructions using a bone window (L = 570, W = 2500). Attenuation values were measured on magnified images by means of a round ROI that was drawn as large as possible to comprehend the largest stone area but no adjacent structures (Fig. 1). The data recorded by the two radiologists were used to calculate mean values and standard deviations, which were used for further analyses.

Fig. 1
figure 1

Manual ROI placement for stone’s attenuation assessment: a bone window must be used and the ROI must be drawn as large as possible, but it must not comprehend structures others than the stone itself

Further evaluations were performed on the 100/Sn140 kV data sets by means of a commercially available automated software (Syngo.Via CT Dual Energy—Kidney Stones, Siemens, Erlangen, Germany). Stone maximum diameter (mm), volume (mm3), attenuation values (mean and standard deviation, in HU) at 100, and Sn140 kV and 100/Sn140 kV attenuation ratios were calculated by the software (Fig. 2) and recorded. Moreover, stone colour on the automatically created colour-coded image (orange = uric acid stones; blue = non-uric acid stones) was annotated.

Fig. 2
figure 2

Example of stone analysis performed by the automated software used in our study: information about stone’s size, volume, attenuation at 100 and 120, and Sn140 kV and 100/Sn140 kV attenuation ratios were automatically provided. Moreover, the stone was colour-coded: orange for uric acid stones and blue for non-uric acid stones

On 120 kV single-energy images, according to the work by Mostafvi et al. [16], stones were considered mainly composed by uric acid if mean attenuation value was <538 HU, by cysteine if mean attenuation value was 538–1064 HU, and by calcium oxalates or phosphates if mean attenuation value was >1064 HU (Table 2). On 100/Sn140 kV dual-energy images, according to the producer’s recommendations, stones were considered mainly composed by uric acid if 100/Sn140 kV attenuation ratio was <1.13, by cysteine if attenuation ratio was 1.13–1.24, and by calcium oxalates or phosphates if attenuation ratio was >1.24 (Table 3).

Table 2 CT cut-off values for renal stones characterization
Table 3 Stones characterization by means of 120 kV single-energy CT

Finally, the two radiologists in consensus analysed dose reports for each patient.

For each examination, the following data were recorded: scan length (mm), CTDIvol (mGy), and DLP (mGy-cm). Effective dose (mSv) was also calculated using the formula E = DLP × 0.015.

Stone analysis

A research in our institutional database showed that 13/30 patients spontaneously expelled the stones and 17/30 underwent stone extraction by means of percutaneous nephrolithotripsy or ureteroscopy. The obtained stones were analysed by means of infrared spectroscopy and classified, according to their prevalent composition, into three categories: uric acid, cysteine, and calcific (calcium oxalates and phosphates). In case of patients presenting more than one stone, stone composition was considered the same for all the stones.

Statistical analysis

Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for both SECT and DECT in predicting renal stones composition were calculated with Fisher’s test using a commercially available software (GraphPad Prism version 5.01 for Windows, GraphPad Software, San Diego California, USA, http://www.graphpad.com); accuracy was also calculated.

Results

50 stones were detected in 30 patients (range 1–4 stones per patient): 26 stones were located in the urinary calices, 15 in the ureters, 8 in the renal pelvis, and 1 in the urinary bladder.

At laboratory, 29/50 (58 %) stones were classified as prevalently composed by calcium oxalates or phosphates, 17/50 (34 %) by uric acid, and 4/50 (8 %) by cysteine.

Stones’ attenuation values, as measured by the two radiologists on the 120 kV data set, are reported in Table 3. Moreover, Fig. 3 shows mean stone attenuation values, subdivided according to their prevalent composition, as found at infrared spectroscopy. 120 kV single-energy CT correctly assessed stone composition in 26/50 (52 %) of the cases: 16/17 uric acid stones were correctly characterized by SECT, while 1/17 was mistakenly characterized as composed by cysteine, 2 out of the 4 cysteine stones were correctly characterized by SECT, whereas 2/4 were mistakenly characterized as composed by uric acid, and 8/29 calcium oxalates or phosphates stones were correctly characterized by SECT, whereas 14/29 were mistakenly characterized as composed by cysteine and 7/29 by uric acid. No statistically significant differences were observed in stone maximum diameter between the stones characterized correctly and incorrectly.

Fig. 3
figure 3

Stones attenuation values (HU) at 120 kV single-energy CT, according to their prevalent composition at infrared spectroscopy

Stones mean maximum diameter, volume, and attenuation values, as calculated by the automated software on the 100/Sn140 kV data sets, are reported in Table 4; no statistically significant differences in stone maximum diameter were observed between the three groups.

Table 4 Stones characterization by means of 100/Sn140 kV dual-energy CT

Moreover, Fig. 4 shows stones 100/Sn140 kV attenuation ratios, subdivided according to their prevalent composition, as found at infrared spectroscopy. Dual-energy CT correctly assessed stone composition in 45/50 (90 %) of the cases: all 17 uric-acid-composed stones were correctly characterized by DECT, 2 out of the 4 cysteine stones were correctly characterized by DECT, whereas 2/4 were mistakenly characterized as composed by calcium oxalates or phosphates, and 26 out of the 29 calcium oxalates were correctly characterized by DECT, whereas 1/29 was characterized as composed by cysteine and 2/29 were characterized as composed by uric acid. Results of stones’ characterization were concordant between SECT and DECT in 24/50 (48 %) of the cases.

Fig. 4
figure 4

Stones attenuation ratios at 100/Sn140 kV dual-energy CT, according to their prevalent composition at infrared spectroscopy

Single-energy CT correctly differentiated uric acid vs. non-uric acid stones in 40/50 (80 %) of the cases, whereas dual-energy CT in 48/50 (96 %) of the cases. No statistically significant differences were observed in maximum diameters between uric acid stones and non-uric acid stones. Sensitivity, specificity, positive predictive value, and negative predicting value for both SECT and DECT in predicting uric-acid renal stones composition are reported in Table 5.

Table 5 Performance of single-energy CT and of dual-energy CT in the recognition of uric acid stones

Mean DLP and effective dose (ED) for the preliminary 120 kV scan were 146 mGy-cm (128–174) and 2.2 mSv (1.9–2.6), respectively. Mean DLP and ED for the added DE scans were 67 mGy-cm (52–72) and 1.0 mSv (0.8–1.1), respectively.

Discussion

The first dual-energy CT experiences are dated back to the late 1970s. In the last decades, various CT scanners have been developed to obtain dual-energy data sets with different techniques. Dual-source dual-energy scanners, single-source dual-energy scanners, single-source dual-energy scanners with fast kV switching, and single-source dual-energy scanners with dual detector layer are currently available from different vendors.

Computed tomography represents, nowadays, the imaging modality of choice in the evaluation of patients with suspected urolithiasis. Besides information about the presence of stones, their location, and the eventual presence of complications, CT has also shown to be useful for urinary stones composition characterization; indeed, a strict correlation between stones’ attenuation values and their chemical composition has been highlighted by other authors [14]. In our series, however, CT attenuation values have demonstrated to be unsatisfactory correlated with stones’ composition (accuracy 52 %) and we have found a lot of overlap between different stone types; in particular, about an half of the calcified stones have shown attenuation values that were comparable with those of uric acid and cysteine ones. A further subanalysis has demonstrated that SECT errors in stones characterization were not correlated with their size; however, in our series, only three stones had a minimum diameter <2 mm, below which partial volume artefacts are most likely to influence HU values determination. On the other hand, our work has demonstrated that dual-energy CT has a high accuracy (90 %) in differentiating the different stone types, performing significantly better than single-energy CT for this aim.

The performances of both SECT and DECT increased if stones’ composition analysis was limited to the differentiation between uric acid and non-uric acid stones, which is also the most relevant information that urologist want to know to tailor the best therapeutic approach; indeed, uric acid stones may be easily dissolved by medical treatment with urine alkalinisation.

SECT correctly differentiated uric acid from non-uric acid stones with a satisfactory accuracy (0.80), but its specificity in recognising uric acid stones was fair (0.73), with a positive predictive value of only 0.64; this may represent a limit to its clinical use, because it may lead to medically treat a group of patients who will not have any benefit from this approach. On the other hand, DECT accuracy in differentiating uric acid and non-uric acid stones was extremely high (0.96), with specificity and PPV of 0.94 and 0.89, respectively; in our series, only two stones were incorrectly classified by DECT: in both cases, the automated software characterized the stones as prevalently composed by uric acid, whereas they were composed by calcium oxalates/phosphates at infrared spectroscopy. Both mistakenly classified stones were located in the ureters, and a JJ ureteral catheter was already in place at the time of CT scan (Fig. 5). This suggests that the presence of a ureteral catheter next to a stone may introduce a certain degree of error in its DECT characterization by means of an automated software, probably due to beam-hardening artefacts caused by JJ catheter itself; on the other hand, differentiation between uric acid and non-uric acid stone partially loses its importance if the stone has already reached the ureter, and a JJ catheter is already in place. In both cases, manual measurement of stone’s attenuation values by means of a round ROI on separated 100 kV and Sn140 kV images and attenuation ratio manual calculation correctly classified the stones as “non-uric acid”.

Fig. 5
figure 5

Stone incorrectly characterized by the automated software. This small stone located next to a ureteral catheter (orange) was characterized as uric acid by the automated software, according to its low 100/Sn140 kV attenuation ratio, whereas infrared spectroscopy characterized it as composed by calcium oxalates. In any case, the automated software colour-coded it in blue (non-uric acid), because of its high attenuation

Another aspect to take into consideration is the added dose given to the patient for dual-energy acquisitions, which, in our series, was in the order of 1 mSv. Although it cannot be considered an unremarkable dose, a correct preoperative characterization of the calculus is fundamental to distinguish the patients who might take advantage from medical therapy from those who would require an interventional approach, possibly avoiding unnecessary invasive procedures and possible complications.

Our study had some limitations. First of all, at 120 kV, we classified the stones according to the density values proposed by Mostafvi et al., which were found out using a GE-scanner, as, to our knowledge, there are no papers that report similar data for Siemens’ ones; this might represent a limitation according the work by Grosjean et al. [18] that highlighted a significant variability in urinary stones CT attenuation values using different scanners. Second, our study population was relatively small, because stone analysis by means of infrared spectroscopy was not available for the majority of patients, in which CT showed the presence of urinary calculi. This was due to the high number of patients that spontaneously expelled the calculus and did not provide it to the laboratory for further analysis. Image quality of the dual-energy acquisition was also judged inadequate in one patient, due to motion artefacts. Finally, we did not consider the presence of mixed stones, classifying the stones only on the base of their prevalent composition; further studies are needed to evaluate the accuracy of DECT in discerning the different components of mixed stones.

In conclusion, dual-energy CT performs significantly better than single-energy CT in renal stone composition determination and reliably discriminates between uric acid and non-uric acid stones. Furthermore, the potential benefits of preoperative characterization of renal stones largely exceed the low risk related to the added radiation dose given to the patient for dual-energy acquisitions.