Introduction

Serotonin (5-hydroxytryptamine, 5-HT) is a tryptophan-derived biogenic amine that acts as a neurotransmitter in the central and peripheral nervous systems in the body [1]. It controls many brain functions, regulates blood pressure and smooth muscle contraction. It has been strongly implicated in several pathological conditions such as hypertension, migraine, depression, schizophrenia, anxiety, anorexia nervosa, dementia and carcinoid syndrome. In addition, it has been associated with sleep disruption, aggression, temperature regulation, sexual behaviour, and pain sensation [16]. It has also been linked to Alzheimer’s disease and vascular dementia along with other neurotransmitters such as dopamine [7].

Serotonin is formed by decarboxylation of 5-hydroxytryptophan in one of tryptophan’s metabolic pathways. Figure 1 shows the synthesis of serotonin from tryptophan and its metabolism into melatonin, 5-hydroxyindole acetic acid (HIAA) and hydroxytryptophol. Serotonin undergoes oxidative deamination followed by subsequent oxidation to form 5-HIAA, which is the predominant metabolite in urine [8]. The amount of serotonin, its synthesis, uptake sites, and receptor binding are all higher in the developing brain, compared with adult values, and these levels decline before puberty. This developmental process has been reported to be disrupted in autistic children [1].

Fig. 1
figure 1

Synthesis and metabolism of serotonin

Dopamine is also a neurotransmitter but has its own system of neurons. It has been shown that serotonin can influence the dopaminergic system [9]. The dopaminergic system is thought to affect a wide range of behaviours and functions, including cognition, motor function, brain-stimulation reward mechanisms, eating and drinking behaviours, sexual behaviour, neuroendocrine regulation and selective attention [10].

Attention deficit–hyperactivity disorder (AD-HKD) is a highly heritable condition which starts in early childhood and has a large impact on a person’s socialisation in later years [11]. Children with AD-HKD disorder experience serious social, academic and psychological impairment. The key symptoms of the condition include inattention, motor hyperactivity and impulsiveness [12]. This condition is one of the most prevalent childhood psychiatric disorders affecting 3–5% of school-aged children and may it progress into adulthood [13]. All clinical samples were taken under the medical supervision of co-author Dr H. Keeley, Consultant Child and Adolescent Psychiatrist.

Disruption of normal monaminergic neurotransmission has been seen as the crucial mechanism linked with AD-HKD [12]. Although many studies have shown that dopamine plays an important role [14], other monoamines like noradrenaline and serotonin have also been linked to this condition [15]. In fact, while most therapeutic agents used in the treatment of AD-HKD are dopaminergic in action, many of the major clinical indicators, e.g. impulsivity are considered to be related to serotinergic function. Also, tricyclic antidepressants and other antidepressants which block the uptake of serotonin have shown to reduce AD-HKD symptoms [16]. Spivak et al. reported that a chronic deficit of serotonin may contribute to the clinical symptoms of the disorder [17, 18].

The difficulty with AD-HKD diagnosis is that there is no specific clinical feature or testing procedure and diagnosis is based on clinical assessment of behaviour along with psychological and neurocognitive evaluation [19]. These evaluations are usually based on a structured interview together with symptoms rated by parents and teachers in different settings using diagnostic scales [20]. The major concerns here are that there may be some children that go undiagnosed and who without intervention risk dysfunction, disability or social impairment and others that may be medicated with psychostimulants without need and suffer the harsh side effects of these drugs such as insomnia, appetite suppression and dysphoria [16].

The aim of this study was to identify possible peripheral biological markers for AD-HKD in order to aid with diagnosis and to monitor the efficacy of treatment. This required the development of an accurate and robust method for the analysis of the possible biomarkers.

There are several methods published on the analysis of serotonin and other related compounds in biological fluids. A variety of methods have been developed to measure serotonin including spectrophotometry [21, 22], LC-fluorometry [23, 24], enzyme immunoassay, and LC-electrochemical detection [25, 26]. LC-mass spectrometric methods is however the method of choice as tandem LC-MS methods provide increased selectivity while reducing the need for dependence on chromatographic separation [2735]. While these methods report good results for the analytes under investigation, the methods do not facilitate multi-target analysis which was the aim of this study. Extensive method optimisation was required in order to obtain optimum results for the simultaneous analysis of all the pertinent analytes. The LC-MS/MS based method described herein delivers excellent sensitivity, selectivity and robustness for dopamine, serotonin and its key metabolite, hydroxyindole acetic acid in clinical samples.

Materials and method

Materials

Chemicals used in this study included formic acid purchased from Merck (Darmstadt, Germany); ammonium acetate and acetic acid were purchased from Sigma-Aldrich (Dublin). Hydrochloric acid and all HPLC-grade solvents (methanol, water, acetonitrile) were purchased from Labscan (Dublin, Ireland). Nitrogen gas was purchased from Irish Oxygen (Ireland). All standards were purchased from Sigma-Aldrich (Dublin, Ireland) and deuterated compounds were purchased from CDN Isotopes (Quebec, Canada). Isolute C18 cartridges were purchased from Biotage (Sweden). Following ethical approval from the Clinical Ethics Research Committee of the Cork Teaching Hospitals samples were received from a test group of 17 children with a clinical diagnosis of AD-HKD attending a Child and Adolescent Mental Health Service, as well as a matched control group.

Standard preparation

Standards (serotonin, dopamine and 5-HIAA) in solvent (water) were prepared from a stock mixture of all compounds (10 μg/ml) by serial dilutions. The deuterated internal standards were subsequently added with final internal standard concentrations for serotonin-d 4 and hydroxyindole acetic acid-d 2 of 1.11 and 2.07 μmol/L, respectively. A deuterated internal standard was purchased for dopamine but it was found that an impurity in the mobile phase had an identical mass (m/z 158) to the deuterated standard which caused continuous interference in the chromatographic run. This resulted in the deuterated dopamine standard being unsuitable as an internal standard. For the urine validation study, aliquots of stock standard solutions were spiked into water that was pH matched with urine.

Sample preparation

On collection of urine samples (10–40 ml), 1 M HCl (0.5 ml) was added as a preservative and samples were extracted and analysed within 24 h of collection, the remainder of the samples were stored at −24°C. Samples were centrifuged (3,000 × g) and the internal standards (serotonin-d 4 and 5-HIAA-d 2, 200 μl) were applied to the urine samples (200 μl). Water acidified to pH 3.5 with acetic acid (800 μl) was applied and the samples were then vortexed. The SPE procedure contained the following steps: the Isolute C18 cartridges were conditioned with methanol (3 ml), followed by water (pH 3.5, 3 ml), the sample containing water (1,000 μl) was then loaded onto the cartridge, washed with a methanol solution (5%, 1 ml) and then eluted with methanol with 0.1 M ammonium acetate (5 ml). Samples were then dried under nitrogen and reconstituted in water (200 μl). An aliquot (5 μl) was injected into the LC-MS/MS.

Separately, quantitation of creatinine in the urine samples were carried out on an Olympus AU640 analyser in an accredited laboratory at Cork University Hospital, the assay principle used for creatinine method was the Jaffe method.

Study of the stability of serotonin, dopamine and hydroxyindole acetic acid in urine

A urine sample (10 ml) was collected and divided into three groups, each group containing two 1 ml aliquots, one of which was acidified with HCl as a preservative and the other left unaltered. Group 1 was stored at room temperature (18°C), group 2 was stored at 4°C and group 3 was stored at −24°C for four consecutive days. Aliquots (200 μl) of all six samples were prepared as in Section Sample Preparation and analysed on each of the 4 days to assess the stability of serotonin, dopamine and hydroxyindole acetic acid.

Instrumentation and Analytical Conditions

Liquid chromatography–tandem mass spectrometry (LC-MS/MS)

A liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of serotonin, dopamine, and 5-HIAA in urine. In order to ensure unambiguous identification, more than one multiple reaction monitoring (MRM) experiment was conducted on each peak, i.e. three product ions (Q3) were selected for each precursor ion (Q1). Separation was performed on an Agilent 1100 series HPLC system (Agilent, Palo Alto, CA, USA) coupled to an API 3000 (Applied Biosystems, Warrington, UK) triple quadrupole mass spectrometer equipped with a turbo-assisted ionspray (ESI) ionisation source (Sciex, Toronto, Canada) in positive mode. Analyst 1.5 software was used for instrument control, data acquisition and data analysis. The sample vials were maintained at 4°C in the thermostatic autosampler. Chromatographic separation was obtained using gradient elution on a reverse phase Hypersil Gold aQ column, 3 μm, 150 × 2.1 mm (Thermo) at 20°C at a flow rate of 200 μl/min. Separation was performed using a binary gradient composed of mobile phase A, 0.1% formic acid in water and mobile phase B, 0.1% formic acid in MeOH. A ramped gradient profile was used as follows: (a) 0 min 90% A; (b) 3 min 80% A; (c) 3.01 min 20% A; (d) 5.5 min 50% A (e) 7 → 12 min 20% A; (f) 12.5 → 20 min 90% A. The injection volume was 5 μl and the eluent flow was diverted to waste for 2 min after sample injection and again after 13 min. MS detection was carried out between 1 and 15 min of the chromatography, total run time of the analysis was 20 min; the dwell time of the method was 1.82 min. The mass spectrometer was operated in positive mode. Q1/Q3 ion pairs outlined in Table 1 were used to allow simultaneous detection of serotonin and related compounds. Optimised values of the MS instrument along with observed ion ratios can be seen in Table 1. Other parameters were kept constant for all analytes, these were, nebuliser gas 8, curtain gas 12, CAD gas 5, ion source voltage 5,000 V, ion source temp 370°C. Once every 3 months, the instrument was calibrated following manufacturer standard operating procedures; however, daily controls and calibration checks were performed for the target compounds to ensure detector stability. No deviation outside ±2.5% were observed during this investigation.

Table 1 Optimised LC-MS/MS parameters

Liquid chromatography–tandem mass spectrometry (LC-FT-MS)

Liquid chromatography coupled to a linear trap quadrupole-Orbitrap mass spectrometer (LTQ-Orbitrap, Thermo, USA) was used to obtain high mass accuracy data of the analytes in urine samples. Samples were analysed at 100,000 resolution and the accurate mass of each analyte was determined to four decimal places. The instrument was operated in full scan mode and ion source parameters were optimised for the analytes. H-ESI source parameters were spray voltage 3 kV, sheath gas 84, auxiliary gas 11, vaporiser temperature 300°C, capillary temperature 275°C, capillary voltage 6 V and tube lens 3 kV. The same column and mobile phase gradient was used as in the section “Liquid chromatography–tandem mass spectrometry (LC-MS/MS)”.

Ion suppression post column infusion assessment

Post column infusion experiments were conducted to determine ion suppression/enhancement effects using the approach described by Choi et al. [36]. The experimental setup used in these experiments involved the infusion of a standard during the analysis of a blank matrix solution. A standard mixture (2.8, 2.6 and 3.3 μmol/L for serotonin, 5-HIAA and dopamine, respectively), monitored by MRM, was introduced at 5 μl/min into the LC eluent post-column. A blank matrix (LC-grade water) was injected (5 μl) via the autosampler into the LC system. The response of the standard mixture was monitored continuously to produce a profile of the matrix effect. Any drop in the constant baseline signal (‘suppression of signal’) indicates presence of interfering matrix components [3739]. The process was repeated for urine samples. Five different urine samples were tested to access any possibility for sample-specific ion suppression effects.

Validation

Validation of the method was carried out in compliance with the EC [40] and ICH [41] guidelines.

Specificity

This method utilises retention time stability, chromatographic separation and ion ratio to determine specificity.

Linearity

The linear range of this method was investigated for serotonin, 5-HIAA and dopamine in urine by construction of a linear curve by serial dilution of analyte compounds. The range of the analytical method was established by confirming an acceptable degree of linearity, trueness and precision within the specified range.

Limits of detection and quantitation

The limit of detection (LOD) and the limit of quantitation (LOQ) were evaluated from the signal to noise ratio (S/N). The LOD and LOQ were calculated for each compound in urine. The S/N was established from the standard deviation of the Y-intercept in six low range calibrations which is then divided by the slope of the average calibration for the six calibrations. This value was then multiplied by 3.3 for the LOD and 10 for the LOQ.

Trueness

The trueness of this method was expressed as percentage relative error of three different concentrations spiked into blank urine, these concentrations were 2,837, 1,135 and 284 nmol/L for serotonin, 2,618, 1,046 and 262 nmol/L for 5-HIAA and 3,268, 1,306 and 326 nmol/L for dopamine. The trueness compares the true value and the value obtained by analysis. Recovery experiments were also carried out, where known concentrations of standard were spiked into urine matrix.

Precision

The precision of the method was evaluated using both intra-day and inter-day studies. Sample numbers of six and nine were used for intra-day repeatability and inter-day reproducibility respectively. Precision was studied using six concentrations over the linear ranges,

Application of mass spectrometry method for serotonin, dopamine and hydroxyindole acetic acid in urine

Urine samples of 20 control samples and 17 test samples were analysed using the validated method. The urine sample concentrations were expressed as a ratio of creatinine concentration in each sample to correct for possible difference in kidney function. This is required to allow accurate quantitation from a single urine sample as 24 h sample collection was not feasible. The presence of the analytes was confirmed using high-resolution mass spectrometry on a LTQ-Orbitrap mass spectrometer.

Results and Discussion

The purpose of this paper is to describe a method that was developed for the analysis of serotonin, 5-HIAA and dopamine in urine samples in order to determine if any of these analytes may be a possible biomarker for AD-HKD in children. There have been a variety of LC-MS methods developed for these compounds but none that were as sensitive, selective and robust as the method presented here.

Other methods of interest in recent years include: Monaghan et al. [42] provide a method for the analysis of serotonin in platelet depleted plasma for use as a biomarker in conditions such as functional gastrointestinal disorders. Protein precipitation is used for sample preparation followed by a cation exchange on-line clean-up step. The LC-MS/MS method has a 6 min analysis, with good recovery (98% average over range 89.5–115.5 nmol/L) and sensitivity (LOD and LOQ of 1.5 and 5 nmol/L, respectively). Peterson et al. [43] determined serotonin levels in serum using capillary electrophoresis-TOF-MS. This method has an LOD of 67.3, 6.2 and 27.4 nmol/L for serotonin, 5-HIAA and dopamine, respectively. Miller et al. [44] report an UPLC-MS method for the analysis of 5-HIAA in plasma as an alternative to urine analysis for the diagnosis of midgut carcinoid tumours. LOD and LOQ for this method were 5 and 15 nmol/L, respectively and the method for this single compound had similar levels of accuracy, precision and recoveries as those reported for this study. While these methods show good sensitivity for the analytes they investigate (serotonin and 5-HIAA, respectively), the sample preparation was often laborious or unsuitable for urine samples.

Kushnir et al. [34] and Vuorensola et al. [35] have described LC-MS methods for the analysis of dopamine in urine samples. Kushnir et al. show a similar sensitivity to the method presented here with an LOQ of 16.3 μmol/L (29.4 μmol/L presented here). The method has a 3.5 min run time but suffers from very low extraction recoveries (71% ± 12%). The sample preparation is designed specifically for catecholamines and may not be effective for serotonin and 5-HIAA. The method provided by Vuorensola et al. compares multiple methods (LC-EC, CE-UV and CV-MS) for the analysis of dopamine and methoxycatecholamines. They conclude that the MS method although more selective is far less sensitive than the CE-UV method.

Perry and Keevil [33] report an on-line extraction LC-MS method for 5-HIAA in urine. The method has a very short run time and good analyte recovery. However, the sensitivity of the method is extremely low with a LOD and a LOQ of 2.8 and 4.0 μmol/L for 5-HIAA (0.010 and 0.036 μmol/L are reported herein). de Jong et al. [45] developed an on-line SPE LC-MS method for 5-HIAA in urine for diagnosing and monitoring patients with carcinoid tumours. This method has a low sensitivity (LOD and LOQ of 0.10 and 0.13 μmol/L) and a marginally reduced recovery (81–98%) in comparison to the method reported here. de Jong et al. [27] have also recently described an automated LC-MS method for serotonin in urinary and plasma samples. The LOQ for serotonin (30 nmol/L) in urine is matched by this study (36 nmol/L) and our recoveries are in the range of 88–135%; with absolute recoveries of 83–85%.

Determination of serotonin using LC-MS/MS

Triple quadrupole mass spectrometry was used to quantify serotonin, dopamine and 5-HIAA in urine. Three Q1/Q3 ion pairs were monitored for each compound. MRM studies were carried out to investigate the fragmentation of the precursor ions into their product ions and establish the collision energy required, so as to provide optimum intensity for each product. This was done by setting up sequences with methods containing various collision energies. For the graphs of these MRM studies see Electronic Supplementary Material Fig. S1. The most abundant MRM ions were chosen for quantitation (as in Electronic Supplementary Material Fig. S1a the 177/160 transition for serotonin was used for quantitation) with additional MRM ion combinations used for unequivocal identification (see Table 1).

The column used in this method was chosen as it gave better retention of early eluting compounds in a high aqueous mobile phase in comparison with other reversed phase columns (C18 and polar-RP columns). The addition of 0.1% formic acid to the mobile phase gave a good signal response for the analytes and assisted in the retention of dopamine on the LC column so as to ensure that it eluted after the column void volume and also avoided the area of intense ion suppression that occurs in the early chromatography region (see Electronic Supplementary Material Fig. S2a).

Validation

Matrix Effects

Continuous post column infusion of a standard solution ensures that all matrix components in a sample that elute from the column are ionised along with the analyte [46]. This allows areas of ion suppression or enhancement to be easily identified. The profile for the urine samples (see Electronic Supplementary Material Fig. S2) display areas of both ion suppression and enhancement particularly close to the elution time of dopamine but through manipulation of the chromatographic gradient the dopamine peak was optimised to elute in an ion suppression free region (Electronic Supplementary Material Fig. S2a). Both serotonin and 5-HIAA are relatively unaffected by matrix effects (Fig. S2b and c, Electronic Supplementary Material) following assessment with different urine samples (n = 5).

A standard addition experiment was carried out on the urine samples (see Electronic Supplementary Material Fig. S3) and the values obtained were compared to those achieved for the optimised simple calibration method; see Table 2. A large deviation between the two would indicate the presence of significant ion suppression. The standard addition samples correlate well with the simple calibration method with results showing insignificant differences for all analytes (an error of 3.12%, 6.13% and 6.07% for serotonin, 5-HIAA and dopamine respectively were observed; Electronic Supplementary Material Fig. S3a–c).

Table 2 Comparison of the % error between standard addition results with calibration curve results for analytes in urine matrix

Specificity

Retention time stability of an analyte is an important parameter to investigate during validation, as shifting retention times can lead to inaccuracies in identification as well as variations in the signal response of the analyte especially in complex matrices. The high selectivity of MRM in LC-MS/MS allows for a higher degree of confidence in using retention time as identification marker. The EC council directive 2002/657/EC (implementing the 96/23) [40] suggests that retention time should not vary more than 5%. For this method retention times were recorded over 3 days with three repeat injections per day of seven standards in the range of (105–3,268 nmol/L) spiked into blank urine matrix. The retention time varied ≤2, 2.8 and 1% for serotonin, dopamine and 5-HIAA, respectively, this is well below the recommended value of 5%. Analytes with an internal standard showed almost no difference in relative retention time as the deuterated internal references matched the retention characteristics to the analytes of interest.

Possible interferences in the analysis of serotonin are N-acetyl-hydroxytryptamine (m/z 219–160) an intermediate in melatonin synthesis and hydroxytryptophol (m/z 178–160) mainly found in urine. The gradient elution used in this method ensures that these compounds eluted separately from the serotonin peak (data not shown).

The three most abundant MRM transitions were chosen for each compound, apart from 5-HIAA and 5-HIAA-d 2 where the two most distinctive MRM ion transitions were employed. Each precursor/product ion allows positive identification of each analyte and the Q1/Q3 ion pairs corresponds to 5.5 identification points according to the EC directive 2002/657/EC (implementing the 96/23) [40]. The ion ratios for all of the MRM transitions for each of the compounds was monitored over the range of 52–3,268 ng/ml. The ion ratios and their standard deviations over this range are provided in Table 1. The ion ratios seen here were observed to be common for all calibrations in standards and samples, indicating that they can be used for analyte confirmation.

Linearity

The linear range was between 0.033 and 3.268 μmol/L for dopamine, 0.057 and 2.84 μmol/L for serotonin and 0.053 and 2.618 μmol/L for 5-HIAA. Table 3 shows the linear range, equation of line and correlation coefficient for each compound in urine. This method showed good linearity with correlation coefficients ≥0.9977 for urine (n = 5). In the equation of the line presented for each analyte in Table 3, x refers to the concentration of the analyte for serotonin, 5-HIAA and dopamine in nmol/L. The y refers to the ratio of peak area of analyte to peak area of internal standard for serotonin and 5-HIAA and peak area alone for dopamine.

Table 3 Results for linear range, trueness and precision for serotonin, 5-HIAA and dopamine in urine

Limits of detection and quantitation

Table 3 shows LOD and LOQ values for serotonin, 5-HIAA and dopamine in urine matrices. The LODs and LOQs for each compound are well below the normal levels usually found in urine samples which are reported as 25–66 μmol/mol, 0–3.9 mmol/mol and 28.8–177.8 μmol/mol of creatinine for serotonin, 5-HIAA and dopamine, respectively [47]. In the case of 5-HIAA, the LOD was ca. 1,000 times smaller than normal levels with LODs for serotonin and dopamine being at least ten times lower than normal values. In this method, for the analysis of 5-HIAA in urine the sample is diluted by a factor of ten to allow it to be analysed in the linear calibration range 52–2,618 nmol/L.

Trueness and precision

The percentage recoveries (%RE) were very good in the urine matrix giving serotonin values of ≤1.16%, 5-HIAA and dopamine gave trueness values of <9% and <5%, respectively, with the higher concentration standard (2,618 and 3,268 nmol/L for 5-HIAA and dopamine) providing excellent results for both compounds at %RE <1% (see Table 3).

Recovery experiments were also carried out, these results are summarised in Table 4. These show excellent recoveries for the standards spiked into urine matrix with results of 98–104%, 101–106% and 91–107% for serotonin, 5-HIAA and dopamine. These results correspond with the post column infusion and standard addition experiments that showed these analytes are relatively unaffected by the ion suppression that is often encountered in the analysis of urine samples.

Table 4 Percentage recovery for compounds in urine matrix

Precision results were excellent for this method, Table 3 shows a list of the relative standard deviations (RSD) for the concentrations analysed. Percentage RSD values are small (1–6% for 3,268–523 nmol/L) for all compounds in the urine matrix even at low concentrations (2–9% for 326–52 nmol/L).

Sample Stability

The results of the stability study for serotonin, 5-HIAA and dopamine over four consecutive days can be seen in Fig. 2a–c. Surprisingly, less analyte loss was observed in the unpreserved samples than the acid-preserved samples. It is well known in clinical biochemistry that urine samples for 5-HIAA measurement should be preserved by acidification. However, the stability data in Fig. 2a and b, shows that for serotonin, the signal intensity decreases by approximately 30% after Day 0 (time zero), indicating that serotonin should ideally be analysed on the day of sample collection. Additionally, Fig. 2a indicates that serotonin appears to be most stable when unpreserved at 4°C. Regarding 5-HIAA, Fig 2c indicates that, aside from the increase in preserved sample at −24°C at Day 3, 5-HIAA appears most stable when unpreserved at room temperature or at 4°C. For this study, all samples were extracted and analysed on the day of collection. However, this study verifies the difficulties that would arise if samples required lengthy storage prior to analysis. This pertinent issue of sample storage will be the focus of future research for the author as samples storage, transportation and extraction is an important consideration in the assessment of AD-HKD patients.

Fig. 2
figure 2

Stability study of serotonin (a), dopamine (b) and 5-HIAA (c) in urine over 4 days at room temperature (RT), 4°C and −24°C with and without an acid preservative

Application of method

Quantitative measurements were carried out for each of the potential markers in the urine samples that were collected from 17 children who had been clinically diagnosed with AD-HKD. A matched control population was also screened. Calibration standards, blanks and controls were analysed along with the samples in each sequence. Figure 3 shows a chromatogram of serotonin, 5-HIAA and dopamine in a typical standard and urine sample. Urine sample levels for the target analytes for both the control and test groups were expressed as micromoles per mole creatinine to ensure correction for the difference in kidney function (See Electronic Supplementary Material Table S1).

Fig. 3
figure 3

a Chromatogram of dopamine (1), serotonin (2), and 5-HIAA (4),in solvent, with 1.3, 1.1 and 1.0 μmol/L, respectively of each standard and 1.1 μmol/L of serotonin-d 4 (3) and 2.1 μmol/L 5-HIAA-d 2 (5). (b) and dopamine (1) (2.136e4 cps), serotonin (2) (7.819e3 cps), and 5-HIAA (4) (1.049e5 cps) in urine samples. Samples shown were diluted by a factor of 10, final concentrations were 0.21, 1.07 and 10.52 μmol/L, respectively

High mass accuracy data was obtained using high-resolution settings (R = 100,000). The resulting accurate mass values for the target compounds gave low PPM error (<2 ppm error) for all urine samples. Figure 4a shows a chromatogram obtained using an LC coupled to an LTQ-Orbitrap mass spectrometer, this clearly illustrates the presence of three peaks that have accurate masses that correspond to the three analytes under investigation. Figure 4b–d shows the spectra containing the accurate masses of each analyte which are m/z 177.1025, 192.0657 and 154.0865 for serotonin, 5-HIAA and dopamine, respectively. They also illustrate the PPM error associated with the accurate mass measurements. Ions with a mass of 500 Da or less require an accuracy of 0.0025 Da to allow for unambiguous assignment of elemental composition [48]. For serotonin, this corresponds to an error of 14 PPM. As can be seen in Fig. 4b–d, the PPM errors are less than 2 PPM providing results to an accuracy value of within 0.00035 Da. These results definitively confirm the presence of these analytes in the urine sample.

Fig. 4
figure 4

a High-resolution chromatogram of dopamine, serotonin and 5-HIAA in a urine sample carried out on a LC-LTQ-Orbitrap MS. b–d Spectra of serotonin (PPM error 1.69), 5-HIAA (PPM error 1.56) and dopamine (PPM error 1.95) illustrating high mass accuracy data

The results of analyte concentrations in the test and control groups were compared to assess the possibility of significant differences between the two groups. Figure 5a–c shows the interquartile ranges for serotonin, 5-HIAA and dopamine. These diagrams show a distinct difference in 5-HIAA concentrations between the test and control groups, with the test group concentration being considerably lower. Concentrations of serotonin and dopamine showed no obvious difference between the two groups.

Fig. 5
figure 5

Diagram showing the interquartile ranges for serotonin (a), 5-HIAA (b) and dopamine (c) concentration (μmol/mol creatinine) in test and control urine

The Mann–Whitney U statistic which uses the median of the values provides a much better comparison for the serotonin, 5-HIAA and dopamine levels detected between the Control and Test urines samples. Table 5 provides the Mann–Whitney U statistic and P values for these results. These indicate that for serotonin and dopamine, the difference in concentrations between the control and tests were not significantly different. However, 5-HIAA was significantly lower in the test group in comparison with the control population (P < 0.001), a P value less than 0.001 indicates that there is a significant difference between the two populations. Therefore, these results suggest that 5-HIAA may be a useful biomarker for AD-HKD.

Table 5 Mann–Whitney U statistic and P value

Conclusion

This study outlines a validated method for the multiplex assay of serotonin, dopamine and 5-HIAA in urine. The method presented is a robust, sensitive and selective method for the quantitation of these analytes. The method was used to carry out a preliminary study to investigate potential biomarkers for the diagnosis of AD-HKD. From the study, it was concluded that the serotonin metabolite 5-HIAA may be a potential biomarker as a significant statistical difference was seen between the control and test groups. Extended studies including larger patient/control cohorts are needed to confirm this hypotheses. The method developed here has the capabilities to be applied to a large cohort study due to its rapidity and robustness with full certainty of analytical data.