1 Introduction

The electromagnetic forming (EMF) is one kind of high-speed forming using pulsed Lorentz force acting on a metallic workpiece to deform it into the required parts [1]. Compared with conventional forming techniques, the EMF has higher forming speed, higher forming limit, and lower occurrence of spring back and wrinkling [2, 3]. Therefore, this forming technique has been widely used in sheet forming [4, 5], tube forming [6,7,8], joining [9], and other kinds of metal manufacturing.

In the electromagnetic tube forming, the distribution of Lorentz force is a significant factor of deformation behavior and forming performance, and the Lorentz force distribution is highly related to the structure and position of the coil. Li et al. [10] studied the tube-forming behavior by varying the relative position of coil and tube and found out the optimal range of relative position for tube flanging. Qiu et al. [11] proposed a concave coil in order to improve the forming homogeneity of the tube and acquired a homogeneous deforming range of 30% when this type of forming coil structure was adopted in electromagnetic tube expansion. However, the majority of works on electromagnetic tube forming still used conventional one single coil. As a result, occurrence of cracking on tube was relatively high with the growth of discharging energy. The main reason was that the Lorentz force mainly distributes on the middle region of tube and in radial direction, which leads to significant thickness reduction of tube wall.

To improve the distribution of Lorentz force acting on the tube, scholars introduced additional forming coils. For example, Cui et al. [12] and Qiu et al. [13] respectively proposed a method of electromagnetic tube forming in which two additional coils are placed at both ends of a tube to provide axial compression Lorentz force. Results showed that the deformation depth of tube can be increased with lower occurrence of cracking, because the thickness reduction of the tube wall is decreased. However, in both studies mentioned above, all of the forming coils were connected in series and driven by one capacitor bank. Therefore, the radial expansion Lorentz force and axial compression Lorentz force could only act on the tube synchronously, and the amplitude and acting time of both Lorentz force also could only be adjusted synchronously through altering the discharging voltage and capacitance of the capacitor bank. Thus, the controllability of the distribution of Lorentz force acting on a tube is poor and cannot meet the requirement of manufacturing flexibly. Based on the space-time–controlled multi-stage pulsed magnetic field forming and manufacturing technology proposed by Li [14], Zhang et al. [15, 16] proposed a novel electromagnetic tube-forming system, which was called “the two-stage coils system,” as shown in Fig. 1. In this system, the coil placed in the central region of the tube (called “middle-coil”) and the coils placed at both ends of the tube (connected in series, called “end-coils”) are driven by two independent capacitor banks, to achieve the flexible control of the Lorentz force distribution on the tube. The experiment results showed that in this forming system, the deformation depth of the tube increased, and no cracking appeared compared with conventional electromagnetic tube-forming system based on one single coil.

Fig. 1
figure 1

Scheme diagram of the two-stage coil system

According to the analysis of deformation behavior of tube in electromagnetic forming with a die carried out by Zhang et al. [17], the excessive radial Lorentz force acting on the tube middle easily leads to the excessive thickness reduction of the tube wall, while the excessive axial Lorentz force acting on the tube ends leads to the overflow of the tube ends. Therefore, the optimization of radial and axial Lorentz force distribution on the tube needs to be further studied, in order to meet different requirements of manufacturing. And it can be concluded that in the proposed two-stage coils system, the optimization of the radial and axial Lorentz force distribution is through adjusting the discharging parameters of the middle-coil and the end-coils.

In this paper, under the premise of fixed discharging parameter of the end-coils, the analysis of the effect of the middle-coil current pulse width on deformation behavior of tube in the proposed two-stage coils system was carried out through simulation. At first, the simulation model of this electromagnetic tube-forming system and the principle of the simulation model were discussed. Then, the tube deformation behaviors under different pulse width of middle-coil current were simulated and analyzed.

2 Principle of the simulation model

In the process of electromagnetic forming, the Lorentz force is generated through the interaction of the magnetic field in the space and the eddy current flows in the workpiece, and the workpiece is deformed under the action of Lorentz force. In the meantime, the deformation of the workpiece will change the geometrical parameters of the system, which leads to the changing of magnetic field distribution. The heating effect of the current also causes temperature rise in the electromagnetic forming system, but according to the research done by Cao et al. [18], the effect of temperature can be neglected, as the temperature rise of a working cycle of electromagnetic forming is relatively small. Thus, electromagnetic forming is a process of sequential coupling between the electromagnetic field model and the mechanical model [19]. However, there exists the problem that the meshes in the air region can be excessively distorted in the case of large deflection, which will lead to the convergence problem [20]. To solve this problem, the electromagnetic field model is transferred to “the current filament method,” which has been applied in the analysis of induction coil gun [21], electromagnetic sheet forming [20], and electromagnetic tube forming [15].

2.1 Current filament method

The current filament method includes two steps: The first is the calculation of current flows in coil wire and eddy current flows in the tube, and the second is the calculation of Lorentz force acting on the tube.

In the first step, the coil and tube are divided into a series of equivalent circuits. In order to describe simply, the equivalent circuits of electromagnetic tube-forming model with one single coil is discussed below. In this model, the number of coil turn is q, and each turn of coil wire is divided into m count of elements. The tube is divided into n count of elements. If the divided elements are small enough, the current of each element can be treated as homogeneous distribution. Figure 2 shows the equivalent circuit of electromagnetic tube forming with one single coil, from which the circuit of kth (k = 1, ..., n) tube element can be described as

Fig. 2
figure 2

Equivalent circuit of the electromagnetic tube forming with one single coil

$$ 0={R}_{sk}{i}_{sk}+{L}_{sk}\frac{d{i}_{sk}}{dt}+\sum \limits_{j=1,j\ne k}^n{M}_{sk- sj}\frac{d{i}_{sj}}{dt}+\sum \limits_{g=1}^q\sum \limits_{h=1}^m{M}_{sk- cgh}\frac{d{i}_{cgh}}{dt}-{e}_{vskr}-{e}_{vskz} $$
(1)

where Rsk, Lsk, and isk represent the resistance, self inductance, and eddy current of the kth tube element, respectively; Msk-sj represents the mutual inductance between the kth and the other tube elements, Msk-cgh represents the mutual inductance between the kth tube element and the coil elements, and icgh represents the current of the hth (h = 1, ..., m) element of the gth (g = 1, ..., q) turn of coil.

The evskr and evskz in Eq. (1) represents the motional electromotive force generated by the radial and axial relative motion between the kth tube element and magnetic field, respectively, which satisfy

$$ {e}_{vskr}=-{v}_{sk r}\left({i}_{sk}\frac{\partial {L}_{sk}}{\partial r}+\sum \limits_{j=1,j\ne k}^n{i}_{sj}\frac{\partial {M}_{sk- sj}}{\partial r}+\sum \limits_{g=1}^q\sum \limits_{h=1}^m{i}_{cgh}\frac{\partial {M}_{sk- cgh}}{\partial r}\right) $$
(2)
$$ {e}_{vskz}=-{v}_{sk z}\left({i}_{sk}\frac{\partial {L}_{sk}}{\partial z}+\sum \limits_{j=1,j\ne k}^n{i}_{sj}\frac{\partial {M}_{sk- sj}}{\partial z}+\sum \limits_{g=1}^q\sum \limits_{h=1}^m{i}_{cgh}\frac{\partial {M}_{sk- cgh}}{\partial z}\right) $$
(3)

where vskr and vskz represent the radial and axial velocity of the kth tube element, respectively.

The circuit of the hth (h = 1, ..., m) element of the gth (g = 1, ..., q) turn of coil can be described as

$$ {\displaystyle \begin{array}{c}{u}_{cgh}={R}_{cgh}{i}_{cgh}+{L}_{cgh}\frac{d{i}_{cgh}}{dt}+\sum \limits_{a=1,a\ne h}^m{M}_{cgh- cga}\frac{d{i}_{cga}}{dt}\\ {}+\sum \limits_{b=1,b\ne g}^q\sum \limits_{h=1}^m{M}_{cgh- cbh}\frac{d{i}_{cbh}}{dt}+\sum \limits_{k=1}^n{M}_{cgh- sk}\frac{d{i}_{sk}}{dt}\end{array}} $$
(4)
$$ {u}_{cg}={u}_{cg1}=\cdots ={u}_{cg h}={u}_{cg m} $$
(5)
$$ {i}_c=\sum \limits_{h=1}^m{i}_{cgh}\left(g=1,\dots, q\right) $$
(6)

where ucgh, Rcgh, and Lcgh represent the voltage, resistance, and self inductance of the hth element of the gth turn of coil, respectively; Mcgh-cga represents the mutual inductance between the hth and the other elements of the gth coil turn; Mcgh-cbh represents the mutual inductance between the hth element of the gth coil turn and all elements of the other coil turns; Mcgh-sk represents the mutual inductance between the hth element of the gth coil turn and the tube elements; ucg represents the voltage of the gth coil turn; and ic represents the current of coil.

The loop of the coil and the capacitor bank satisfies

$$ {u}_p=\left({R}_l{i}_c+{L}_l\frac{d{i}_c}{dt}\right)+\sum \limits_{g=1}^q{u}_{cg} $$
(7)
$$ {i}_p=-{C}_p\frac{d{u}_p}{dt} $$
(8)
$$ \left\{\begin{array}{c}{i}_c={i}_p+{i}_d\\ {}{i}_d=\left\{\begin{array}{c}0,\left({u}_p\ge 0\right)\\ {}-\frac{u_p}{R_d},\left({u}_p<0\right)\end{array}\right.\end{array}\right. $$
(9)

where up is the voltage of capacitor bank; Rl and Ll are the inner resistance and inductance of the power line, respectively; Cp is the capacitance of the capacitor bank; ip is the current flowing out of the capacitor; and id and Rd are the current and resistance of the crowbar circuit [21], respectively.

From Eqs. (1) to (9), the current of all tube elements can be calculated. In other words, the eddy current distribution in the tube can be acquired.

In the second step, according to the virtual displacement method, the radial and axial Lorentz force of the kth (k = 1, ..., n) tube element can be described as

$$ {f}_{sk r}={i}_{sk}\left(\frac{1}{2}{i}_{sk}\frac{\partial {L}_{sk}}{\partial r}+\sum \limits_{j=1,j\ne k}^n{i}_{sj}\frac{\partial {M}_{sk- sj}}{\partial r}+\sum \limits_{g=1}^q\sum \limits_{h=1}^m{i}_{cgh}\frac{\partial {M}_{sk- cgh}}{\partial r}\right) $$
(10)
$$ {f}_{sk z}={i}_{sk}\left(\frac{1}{2}{i}_{sk}\frac{\partial {L}_{sk}}{\partial z}+\sum \limits_{j=1,j\ne k}^n{i}_{sj}\frac{\partial {M}_{sk- sj}}{\partial z}+\sum \limits_{g=1}^q\sum \limits_{h=1}^m{i}_{cgh}\frac{\partial {M}_{sk- cgh}}{\partial z}\right) $$
(11)

Therefore, the Lorentz force distribution on the tube can be acquired from Eqs. (10) and (11).

A verification of the reliability of the equivalent circuits and the Lorentz force calculating method above based on current filament method has been carried out by the same electromagnetic tube-forming model built by the COMSOL Multiphysics, in which the discharging voltage is 7.0 kV, the capacitance is 320 μF, the resistance of the crowbar circuit is 100 mΩ, and the inner resistance and inductance of the power line are 20 mΩ and 5 μH, respectively. Also, in the current filament model and the COMSOL model, the coil has an inner radius of 35.0 mm, an outer radius of 46.0 mm, a length of 40.0 mm, and 40 turns of wire (the dimension is 2.0 mm × 4.0 mm per turn), and the tube has an inner radius of 48.0 mm, a length of 200.0 mm, and a thickness of 2.0 mm. The waveform of coil current and radial Lorentz force acting on the whole tube calculated in the current filament method agrees well with the corresponding waveform acquired from the COMSOL, as shown in Figs. 3 and 4. Thus, the calculating results of the current filament method have good accuracy.

Fig. 3
figure 3

Comparison of coil current waveform between the calculating result of the current filament method and the COMSOL model

Fig. 4
figure 4

Comparison of radial Lorentz force waveform between the calculating result of the current filament method and the COMSOL model

To the two-stage coils system in this work, the mutual inductance between the elements of the middle-coil and the end-coils should be taken into account on the basis of Eqs. (1) to (9).

2.2 The mechanical model

In the electromagnetic forming process, the tube is under the acting of Lorentz force, and the friction force generated from the contact between the tube and the die. Thus, the motion equation of the tube can be described as

$$ f+\nabla \cdotp \sigma =\rho \frac{\partial^2d}{\partial {t}^2} $$
(12)

where f is the total external force acting on the tube, including Lorentz force and friction force; σ is the stress tensor; ρ is the density of the tube material; and d is the displacement vector.

As the electromagnetic forming is high-speed forming, the strain rate has great influence in the forming process of the workpiece. Thus, the Cowper-Symonds model is adopted, which can be described as [22]

$$ \sigma ={\sigma}_y\left[1+{\left(\frac{\varepsilon_p}{C}\right)}^m\right] $$
(13)

where σy is the yield stress, and εp is the plastic strain rate. For aluminum alloy, the parameter C equals to 6500, and m equals to 0.25.

In this work, the distribution of eddy current and Lorentz force on tube is calculated in MATLAB, and the deformation behavior of tube is simulated in ANSYS. The flowchart of the simulation model is shown in Fig. 5.

Fig. 5
figure 5

Flowchart of the simulation model

2.3 Verification of the simulation model

To verify the feasibility of the simulation model above, a comparison of the deformation result between simulation and experiment has been carried out. The experiment result is from our previous work, in which the aluminum tube has a length of 120.0 mm, a diameter of 100.0 mm, and a thickness of 1.5 mm. The capacitor bank related to middle-coil has a capacitance of 320 μF, and the discharging voltage is 7.0 kV. The capacitor bank related to end-coils has a capacitance of 320 μF, and the discharging voltage is 12.0 kV. The deformation result of the simulation and experiment is shown in Fig. 6, from which we can find that the deformation depth is 9.0 mm, and the end flowing is 3.5 mm in the simulation result, and the deformation depth is 9.2 mm, and the end flowing is 3.8 mm in the experiment result. The simulation result agrees well with the experiment results, which indicates that the calculating result of the simulation model above has good reliability.

Fig. 6
figure 6

Verification of the simulation model. a Simulation result. b Experiment result

3 Results and discussions

3.1 Parameters of the forming system

In this work, the two-stage coils system consist of middle-coil, end-coils, and two capacitor banks. The middle-coil which attached to capacitor bank 1 is inside the tube and placed in the middle region. The end-coils which attached to capacitor bank 2 consist of two coils connected in series and placed at both ends of the tube. The geometrical structure of the forming system is shown in Fig. 7. The coils are made of copper wires which has a cross-section of 2 mm (radial) × 4 mm (axial), and 1-mm space between each two layers in the radial direction, as shown in Fig. 8. The middle-coil has 4 layers in the radial direction, and each layer has 10 number of turns. Each coil of the end-coils has 4 layers in the radial direction, and each layer has 3 number of turns. The material of the tube in this study is aluminum AA1060, which has a conductivity of 3.597 × 107 S/m, a relative permeability of 1, a Young’s modulus of 69 GPa, a Poisson ratio of 0.33, and an initial yield stress of 106 MPa. The geometrical parameters are shown in Table 1. The electromagnetic parameters are shown in Table 2, in which the “variable” represents the items which will be varied and discussed in the following sections. All the simulation analyses in the following sections are under the premise of equal discharging parameters of end-coils. In other words, the C2 and U2 are kept at 320 μF and 11.0 kV, respectively.

Fig. 7
figure 7

Geometrical structure of the forming system

Fig. 8
figure 8

Geometrical structure of the coil wires

Table 1 Geometrical parameters
Table 2 Electromagnetic parameters

3.2 Simulation under equal discharging energy of capacitor bank 1

In order to initially investigate the effect of pulse width of middle-coil current, three cases are set under equal discharging energy of capacitor bank 1, as shown in Table 3. The discharging energy of capacitor bank 1 satisfies

$$ {W}_1=\frac{1}{2}{C}_1{U}_1^2 $$
(14)

where W1 is the discharging energy, C1 is the capacitance of capacitor bank, and U1 is the discharging voltage.

Table 3 Three cases of equal discharging energy

Figure 9 shows the waveform of the middle-coil current in the three cases in which the discharging energy is equal. The waveforms show that in Case 1, the peak value of the middle-coil current is larger, but the peak time is earlier than Case 2 and Case 3, and Case 3 has the smallest peak value of the middle-coil current and the latest peak time in all the three cases. It can be concluded that when the capacitance C1 is larger, the pulse width of the middle-coil current is longer. However, the peak value of the middle-coil current is relatively small under equal W1 when adopting larger capacitance C1.

Fig. 9
figure 9

Middle-coil currents under equal W1

To acquire the radial Lorentz force acting on tube middle, we take the middle part of the tube into account, which has a length equal to the deforming region (hg + 2 × rf). The waveform of the radial Lorentz force acting on the middle in the three cases are shown in Fig. 10. Compared with the corresponding cases in Fig. 9, it can be concluded that the larger the peak value of the middle-coil current, the stronger the intensity of the radial Lorentz force, and the larger the pulse width of the middle-coil current, the larger the pulse width of the radial Lorentz force. Larger pulse width indicates longer acting time of radial Lorentz force. Under equal discharging energy, the radial Lorentz force in Case 1 has the strongest intensity but the shortest acting time, while the radial Lorentz force in Case 3 has the weakest intensity but the longest acting time. The comparison of the middle-coil current and radial Lorentz force acting on the tube middle in the three cases are shown in Table 4.

Fig. 10
figure 10

Radial Lorentz force of middle part of tube under equal W1

Table 4 Characteristics of the middle-coil current and radial Lorentz force under equal discharging energy W1 of the capacitor bank 1

Figure 11 shows the radial displacement of the deformed tubes of the three cases in which the discharging energy is equal. The maximum radial displacement of the deformed tube of Case 1, Case 2, and Case 3 is 16.4 mm, 16.0 mm, and 14.6 mm, respectively. The comparison of the maximum radial displacement and end flowing of the tube in each case is shown in Fig. 12. It can be found that Case 1 has the largest radial displacement and end flowing, which indicates that the smaller C1, the larger radial displacement and end flowing under equal discharging energy W1.

Fig. 11
figure 11

Radial displacement of the deformed tubes under equal W1

Fig. 12
figure 12

Maximum radial displacement and end flowing of tube under equal W1

Figure 13 shows the deformed tube profile in the die region in the three cases. We can find that the profile of the deformed tube in Case 3 is better than that in Case 1 and Case 2, as the tube has the trend of fitting the die fillet. However, in Case 1, the tube profile cannot reach the fillet of the die, though it has larger radial deformation depth and axial end flowing than Case 3.

Fig. 13
figure 13

Profile in the die region of the deformed tubes under equal W1

Figures 14, 15 and 16 show the comparison between the radial Lorentz force on the middle and axial Lorentz force on the ends of the tube in the three cases, respectively. We can find that besides the obvious difference between the radial Lorentz force acting on the tube middle, the peak value, peak time, and acting time of axial Lorentz force on the tube ends in the three cases are similar. Combining the results shown from Figs. 11, 12, 13, 14, 15 to Fig. 16, it can be concluded that the radial displacement and end flowing of the tube are determined by the radial Lorentz force acting on the tube middle and the axial Lorentz force acting on the tube ends, and the profile of the deformed tube is influenced not only by the intensity, but also by the waveform of the radial and axial Lorentz force. The detailed analyses are as follows:

  1. 1.

    Case 1 has the largest radial displacement and end flowing, as its radial Lorentz force acting on tube middle is obviously larger than that of Case 2 and Case 3. However, the pulse width of the radial Lorentz force is relatively short, and the peak time comes obviously earlier than the peak time of the axial Lorentz force, with time difference Δt = 0.04 ms. In this condition, the main process of the radial expansion of the tube middle is before the process of the axial flowing of the tube ends. As a result, the intensity of the radial Lorentz force on the middle is relatively weak during the process of end flowing, which leads to the overflowing of tube ends, and the deformed profile cannot reach the fillet of the die.

  2. 2.

    Case 2 has the medium radial displacement and end flowing in the three cases, because of the medium intensity and acting time of the radial Lorentz force. The peak time comes obviously earlier than the peak time of the axial Lorentz force, with time difference Δt = 0.03 ms, which leads to the similar characteristic of tube profile compared with Case 1.

  3. 3.

    In Case 3, the radial displacement and end flowing are relatively small. However, the pulse width of radial Lorentz force is longer than that of Case 1 and Case 2, and the time difference between the peak time of the radial Lorentz force and the axial Lorentz force is Δt = 0.005 ms, which is the smallest in all the three cases. In this condition, the acting time of the radial Lorentz force on the middle is relatively long, and the process of radial expansion of tube middle and the axial flowing of the tube ends are almost synchronous, which results in the best profile of deformed tube in the three cases.

Fig. 14
figure 14

Radial Lorentz force on the middle and axial Lorentz force on ends of tube in C1 = 160 μF, U1 = 10.0 kV

Fig. 15
figure 15

Radial Lorentz force on the middle and axial Lorentz force on ends of tube in C1 = 320 μF, U1 = 7.0 kV

Fig. 16
figure 16

Radial Lorentz force on the middle and axial Lorentz force on ends of tube in C1 = 640 μF, U1 = 5.0 kV

Figure 17 shows the distribution of thickness reduction along the length direction of the tube in the three cases. The maximum thickness reduction of the deformed tube in Case 1, Case 2, and Case 3 are 16.1%, 14.0%, and 11.7%, respectively. It can be concluded that the deformed tube in Case 1 has the highest occurrence of cracking, because the occurrence of cracking is related to maximum thickness reduction.

Fig. 17
figure 17

Thickness reduction distribution under equal W1

3.3 Simulation under equal pulse width of middle-coil current

From Section 3.2, we can find that the larger capacitance C1, the larger the pulse width of the middle-coil current. In this section, the effect of the pulse width of the middle-coil current is further investigated with equal C1.

Figure 18 shows the radial displacement and the profile of the tube of U1 = 10.0 kV and U1 = 12.0 kV when C1 = 160 μF. It can be found that when U1 grows from 10.0 to 12.0 kV, the maximum radial displacement of the tube increases from 16.4 to 17.2 mm, while the profile of the deformed tube still cannot reach the fillet of the die. Figure 19 shows the distribution of thickness reduction along the length direction of the tube when C1 = 160 μF, which shows that the thickness reduction increases as the growing of U1, and the maximum thickness reduction reaches 19.5% when U1 = 12.0 kV.

Fig. 18
figure 18

Radial displacement and deformed tube profile of U1 = 10.0 kV and U1 = 12.0 kV when C1 = 160 μF

Fig. 19
figure 19

Thickness reduction distribution when C1 = 160 μF

Figure 20 shows the radial displacement and profile of the tube of U1 = 7.0 kV and U1 = 9.0 kV when C1 = 320 μF. With the growing of U1, the maximum radial displacement of the tube increases from 16.0 to 17.9 mm, and the tube profile is obviously closer to the die profile compared with the case of C1 = 160 μF, U1 = 12.0 kV. Figure 21 shows the distribution of thickness reduction along the length direction of the tube when C1 = 320 μF, in which we can find that the maximum thickness reduction reaches 18.4% when U1 = 9.0 kV. Compared with the case of C1 = 160 μF, U1 = 12.0 kV, the maximum radial displacement is 0.7 mm larger, and maximum thickness reduction is 1.1% less.

Fig. 20
figure 20

Radial displacement and deformed tube profile of U1 = 7.0 kV and U1 = 9.0 kV when C1 = 320 μF

Fig. 21
figure 21

Thickness reduction distribution when C1 = 320 μF

Figure 22 shows the radial displacement and profile of tube of U1 = 5.0 kV and U1 = 7.0 kV when C1 = 640 μF. The results show that the maximum radial displacement of the tube increases from 14.6 to 18.3 mm with the U1 growing from 5.0 to 7.0 kV. The deformed tube profile of U1 = 7.0 kV fits well with the die fillet. Figure 23 shows the distribution of thickness reduction along the length direction of the tube when C1 = 640 μF, which shows the maximum thickness reduction reaches 17.4% when U1 = 7.0 kV. Compared with the case of C1 = 320 μF, U1 = 9.0 kV, the maximum radial displacement is 0.4 mm larger, and maximum thickness reduction is 1.0% less.

Fig. 22
figure 22

Radial displacement and deformed tube profile of U1 = 5.0 kV and U1 = 7.0 kV when C1 = 640 μF

Fig. 23
figure 23

Thickness reduction distribution when C1 = 640 μF

The comparison of the maximum radial displacement and maximum thickness reduction of the deformed tube between C1 = 160 μF, C1 = 320 μF, and C1 = 640 μF is shown in Fig. 24. The comparison shows that when C1 is larger, the tube can achieve larger deformation depth with less thickness reduction compared with smaller C1. It can be predicted that under equal deformation depth, the occurrence of cracking when adopting longer pulse width of the middle-coil current is less than the case using the shorter pulse width of the middle-coil current.

Fig. 24
figure 24

Comparison of maximum radial displacement and maximum thickness reduction between C1 = 160 μF, C1 = 320 μF, and C1 = 640 μF

4 Discussion

According to the simulation investigation of the pulse width of the middle-coil current in electromagnetic tube forming with two-stage coils system under the premise of equal discharging parameters of the end-coils, which have been shown in Sections 3.2 and 3.3, we can find that:

  1. 1.

    To the short pulse width of middle-coil current, the intensity of radial Lorentz force acting on tube middle is stronger than that of the long pulse width of the middle-coil current under equal discharging energy of capacitor bank 1. This is beneficial for the radial displacement of the deforming region and axial flowing of tube ends. However, the occurrence of cracking is higher, as shown in Figs. 17 and 19, and the profile of the deformed tube is difficult to reach the die profile, as shown in Fig. 18. The reason is that according to Fig. 14, the acting time of radial Lorentz force is relatively short, and the peak time comes obviously earlier than the peak time of the axial Lorentz force, which leads to the asynchronous process of the radial expansion and end flowing. As a result, the tube profile is bad due to the overflowing of tube ends and the excessive increase of thickness reduction due to the excessive expansion of radial direction.

  2. 2.

    To the long pulse width of the middle-coil current, according to Fig. 16, the acting time of the radial Lorentz force is relatively long, and the time difference between peak time of radial Lorentz force and axial Lorentz force is relatively small. Under this condition, the process of radial expansion of tube middle and the axial flowing of tube ends is almost synchronous. The results are larger deformation depth with less occurrence of cracking compared with the cases of short pulse width, as shown in Fig. 24, and the good profile of the deformed tube, as shown in Fig. 22.

Therefore, the shorter the pulse width of the middle-coil current, the larger the deformation depth of the tube under equal discharging energy, but the higher occurrence of the cracking and worse tube profile. The longer the pulse width of the middle-coil current, the better the profile of the deformed tube, and the occurrence of cracking is less under the same deformation depth compared with the shorter pulse width. It can be concluded that the short pulse width of the middle-coil current can achieve larger deformation depth of the tube under relatively small discharging energy, while the long pulse width of the middle-coil current can achieve the higher requirement of the tube profile and deforming quality.

5 Conclusion

In this work, the deformation behavior of tube under different pulse width of middle-coil current in two-stage coils system is studied, and the effect of the pulse width of middle-coil current is discussed. Results show that the short pulse width of the middle-coil current can achieve larger deformation depth of the tube under relatively small discharging energy, and the long pulse width of the middle-coil current has good performance in the deformed profile. What is more, the thickness reduction in the case of long pulse width of the middle-coil current is less than the case of short pulse width of the middle-coil current under equal deformation depth of the tube. More investigations and significant results of the two-stage coils system will be further developed through simulations and experiments in the future.