Avoid common mistakes on your manuscript.
Introduction
The heart and the arterial system are anatomically and functionally connected, although they are frequently studied as separate structures with independent functions. The arterial tree does not act solely as mere conduits for blood flow distribution to the organs but it also modulates the ventricular ejection, transforming the pulsatile stroke volume (SV) into a peripheral continuous flow (essential for metabolic exchange), and maintaining blood pressure (BP) during diastole (necessary for coronary perfusion). Therefore, a complete description of the cardiovascular system should consider not only the cardiac function but also the arterial system and how both work with each other [1, 2].
Arterial load as a measure of afterload
When trying to understand how the heart interacts with the arterial system, one must know the arterial load (AL), i.e., the external opposition that must be overcome by the ventricles during ejection [2, 3]. AL, however, does not represent any specific property of the arterial system [4]. On the contrary, it gathers all extracardiac factors opposing the movement of blood out of the heart into the systemic and pulmonary systems, compromising different arterial properties, blood viscosity, and the effects of arterial wave reflections [5]. Therefore, AL can be considered as a net measure of cardiac afterload [4].
The importance of AL can be easily understood when one considers that common pathological situations, such as heart failure or systemic and pulmonary hypertension, are profoundly related to a mismatched arterial load [6, 7]. Furthermore, well-established treatments (e.g., noninvasive mechanical ventilation for acute pulmonary edema or arterial vasodilators for systemic and pulmonary hypertension) have proven beneficial through a reduction in AL [6, 8].
Arterial load as a determinant of arterial pressure
The BP is the result of the interaction between blood flow and AL [2]. AL modulates the cardiac output in order to keep constant tisular perfusion pressure. Therefore, BP depends not only on flow but also on AL (Fig. 1). This explains why caution should be applied when using BP as a surrogate for blood flow during fluid challenge [9], since variations in AL may ultimately determine the effects of fluids on BP [10].
Similarly, variations in AL are known to affect the reliability of so-called pulse-contour methods for estimation of SV from the BP [11]. Furthermore, the ability of these techniques for tracking changes in SV depends on how AL is assessed in order to establish a valid pressure–flow relationship.
Arterial load indices
Traditionally, systemic vascular resistance (SVR) has been used to characterize the arterial system and to obtain a gross simplification of AL. However, using SVR as a descriptor of the whole arterial system is clearly inadequate. SVR represents the opposition to a steady flow, but neither blood flow and BP are constant but are cyclic, because of repeated contractions of the heart. Furthermore, the distribution of SVR is not homogenous along the vascular tree [5], and the assumption that central venous pressure as a downstream pressure in classical calculation of SVR could lead to an overestimation of the actual resistance [12].
Because of the oscillatory nature of the BP and flow, the gold standard for assessing AL is the arterial impedance (Z in) [5]. Unlike SVR, Z in represents the complex ratio between pulsatile pressure and flow. Z in provides the most comprehensive description of the AL, integrating the mechanical properties of the arterial system and the effects of arterial wave reflections [5]. Regrettably, Z in can be challenging to measure and to interpret in clinical practice, thus Z in has been appropriately simplified in familiar interpretable surrogates, such as the 3-element Windkessel model of arterial system [13].
Effective arterial elastance as an index of arterial load
Back in the early 1980s, Sunagawa et al. published a landmark paper in which they proposed that all elements integrating AL can be characterized into a single variable called effective arterial elastance (Ea) [2], which is the change in pressure for a given change in volume. However, Ea is not a measure of arterial stiffness, but it incorporates the principal features of AL, including steady and pulsatile components [2, 3]. Ea is therefore an integrative measure of afterload [3].
An advantage of Ea is that it is computed as the ratio between ventricular end-systolic pressure and SV. End-systolic pressure can be estimated using 90 % of systolic BP [3, 6]. SV can be measured using current hemodynamic monitors or noninvasively by echocardiography. So, Ea can be calculated at the bedside without requiring any complex technology. The reliability of Ea for estimating Z in has been repeatedly demonstrated, and its usefulness for characterizing AL has been recognized over the last three decades [3, 7, 14]. Moreover, since Ea shares the same units of ventricular elastance (Emax), the gold standard for estimating the ventricular contractility, both parameters can thus be related, allowing the assessment of right and left ventriculo-arterial coupling, an index of cardiovascular efficiency [2, 6, 7, 15].
Functional assessment of arterial load: the dynamic arterial elastance
The dynamic arterial elastance (Eadyn), or the ratio between pulse pressure variation and SV variation, has been suggested as a functional assessment of AL [16]. Eadyn represents the dynamic interaction between BP and SV during a respiratory cycle, and it may be useful for the prediction of BP response to fluid challenge in preload-dependent patients [16].
Conclusions
Over recent years, a growing interest in cardiovascular physiology has been aroused. This interest has been mostly focused on venous return and cardiac function. However, our knowledge of the arterial system is still mostly simplified to the estimation of vascular resistance. A better understanding of AL will lead to enhanced knowledge of the underlying processes involved in cardiovascular diseases and will hopefully aid the development of new tools and interventions to monitor and treat these diseases.
References
Starling MR (1993) Left ventricular-arterial coupling relations in the normal human heart. Am Heart J 125:1659–1666
Sunagawa K, Maughan WL, Burkhoff D, Sagawa K (1983) Left ventricular interaction with arterial load studied in isolated canine ventricle. Am J Physiol 245:H773–H780
Kelly RP, Ting CT, Yang TM, Liu CP, Maughan WL, Chang MS, Kass DA (1992) Effective arterial elastance as index of arterial vascular load in humans. Circulation 86:513–521
Milnor WR (1975) Arterial impedance as ventricular afterload. Circ Res 36:565–570
Nichols WW, O’Rourke M (2005) McDonald’s blood flow in arteries: theoretical, experimental and clinical principles. Oxford University Press, Oxford
Guarracino F, Baldassarri R, Pinsky MR (2013) Ventriculo-arterial decoupling in acutely altered hemodynamic states. Crit Care 17:213
Chantler PD, Lakatta EG (2012) Arterial-ventricular coupling with aging and disease. Front Physiol 3:90
Ky B, French B, May Khan A, Plappert T, Wang A, Chirinos JA, Fang JC, Sweitzer NK, Borlaug BA, Kass DA, St John Sutton M, Cappola TP (2013) Ventricular-arterial coupling, remodeling, and prognosis in chronic heart failure. J Am Coll Cardiol 62:1165–1172
Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant JY, De Backer D, Investigators F, Group ET (2015) Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med 41:1529–1537
Monge Garcia MI, Guijo Gonzalez P, Gracia Romero M, Gil Cano A, Oscier C, Rhodes A, Grounds RM, Cecconi M (2015) Effects of fluid administration on arterial load in septic shock patients. Intensive Care Med 41:1247–1255
Monge Garcia MI, Romero MG, Cano AG, Rhodes A, Grounds RM, Cecconi M (2013) Impact of arterial load on the agreement between pulse pressure analysis and esophageal Doppler. Crit Care 17:R113
Maas JJ, de Wilde RB, Aarts LP, Pinsky MR, Jansen JR (2012) Determination of vascular waterfall phenomenon by bedside measurement of mean systemic filling pressure and critical closing pressure in the intensive care unit. Anesth Analg 114:803–810
Westerhof N, Lankhaar JW, Westerhof BE (2009) The arterial Windkessel. Med Biol Eng Comput 47:131–141
Sunagawa K, Maughan WL, Sagawa K (1985) Optimal arterial resistance for the maximal stroke work studied in isolated canine left ventricle. Circ Res 56:586–595
Morimont P, Lambermont B, Ghuysen A, Gerard P, Kolh P, Lancellotti P, Tchana-Sato V, Desaive T, D’Orio V (2008) Effective arterial elastance as an index of pulmonary vascular load. Am J Physiol Heart Circ Physiol 294:H2736–H2742
Monge Garcia M, Gracia Romero M, Gil Cano A, Aya HD, Rhodes A, Grounds R, Cecconi M (2014) Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study. Crit Care 18:626
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare no conflict of interest regarding this commentary.
Rights and permissions
About this article
Cite this article
Monge García, M.I., Saludes Orduña, P. & Cecconi, M. Understanding arterial load. Intensive Care Med 42, 1625–1627 (2016). https://doi.org/10.1007/s00134-016-4212-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00134-016-4212-z