Historical note

The earliest description of cardiorespiratory interactions may be traced back to the first invasive measurement of arterial blood pressure, carried out by Stephen Hales. In the early eighteenth century, this renowned English physiologist inserted a glass tube into the carotid artery of a mare and noted that the height of the column of blood fluctuated with the animal’s respiratory efforts. Hales did not stop at describing these fluctuations, but he also theorized on the possible effects of respiration on venous return [1]. Many of the concepts which underly our current understanding of cardiorespiratory interactions were already in place at the start of the twentieth century. For example, the idea that the fall in pleural pressure could impede left ventricular ejection during inspiration was put forward by Donders in 1853, and Riegel mentioned the potential role of this mechanism in the pathogenesis of pulsus paradoxus in 1903 [1].

However, the diffusion and extension of this new knowledge had to await the need for practical applications. The first one arose during World War II, when the US Air Force sought to enhance the ability of its pilots to fly at very high altitude in airplanes with unpressurized cockpits. In these conditions, hypoxia was the limiting factor. It was calculated that every 5 cm H2O of pressure added selectively to the face mask supplying the pilot with 100% oxygen would increase the maximal tolerable altitude by 1,000 feet [1, 2]. To clarify the possible adverse effects of such positive pressure breathing, the US Air Force sponsored studies by several groups of prominent physiologists, in particular Rahn and Fenn as well as Carr and Essex. These studies clearly described the effects of pressure breathing on intramural vascular pressures and cardiac output [24]. In the late 1940s, seminal work conducted by Cournand and colleagues at Columbia University demonstrated the major role of a reduction in right ventricular transmural filling pressure in the depression of cardiac output caused by positive pressure mechanical inflation (Fig. 1) [5]. In the following years, Guyton provided a theoretical framework of particular relevance to these observations [6]. This framework remains important to our present understanding of cardiorespiratory interactions. It will now be shortly presented.

Fig. 1
figure 1

Some of Cournand’s original data showing a direct relationship between the effects of intermittent positive pressure breathing (IPPB) on right ventricular filling pressure and on cardiac output. A, B, and C designate three individual patients, with two data points for each. The right ventricle was catheterized. IPPB was administered via a face mask. Due to the presence of a therapeutic pneumothorax, pleural pressure could be easily obtained. In stable ventilatory conditions, right ventricular end-diastolic pressure and pleural pressure (both measured relative to atmosphere) were averaged over one full respiratory cycle, and the difference of these two values indicated right ventricular net filling (i.e., transmural) pressure. Cardiac output was measured with the direct Fick method. The abscissa indicates the change in cardiac output observed when switching from spontaneous breathing (SB, i.e., ambient pressure in face mask) to IPPB, expressed in % of the baseline value in SB. The ordinate shows the concomitant change in right ventricular end-diastolic transmural pressure (in mm Hg). Note the inverted scale of both axes. The 3 points on the upper right part of the plot (which indicate that a large decrease in transmural filling pressure was associated with a marked depression of cardiac output) were obtained when switching from SB to a pattern of IPPB with a high I/E ratio (>1) and some positive end-expiratory pressure (3 cm H2O), thus inducing a relatively large increase in mean airway pressure (P aw). The group of 3 points on the lower left correspond to a switch from SB to IPPB with an I/E ratio <1 and no positive end-expiratory pressure, a pattern which raised mean P aw to a lesser extent, and neither decreased transmural filling pressure nor depressed cardiac output. Reproduced from [5], with permission from the American Physiological Society

Guyton’s description of integrated cardiocirculatory function

Venous return curve

The term capacitance vessels designates the highly distensible vessels of the circulatory system, in practice largely the veins (Chap. 10 of [6]). The veins, and especially the small veins [7], contain the major fraction—approximately 70%—of the total systemic blood volume. They are not only highly distensible, but also contain substantial volume even when their transmural pressure is near zero, that is, they have a large unstressed volume. Magder [8, 9] has proposed a representation of venous capacitance as a reservoir drained through an opening in the side rather than the bottom (Fig. 2a). The liquid below the opening represents the unstressed volume, which cannot escape from the system. The amount of liquid above the opening is the stressed volume, which alone generates a pressure known as the mean systemic filling pressure (MSFP). The blood flow from the reservoir to the heart, i.e., the flow of venous return (Q RV), is governed by the equation

$$ Q_{\text{RV}} = ({\text{MSFP}} - {\text{RAP}})/R_{\text{v}} $$
(1)

where MSFP and RAP (right atrial pressure) are measured relative to atmosphere, and R v is the resistance to venous return. Thus, the numerator of Eq. 1 is the pressure gradient which drives venous return. If MSFP and R v remain constant, it can be seen from Eq. 1, that Q RV must increase when RAP decreases. However, if RAP is lowered below a critical pressure (P crit) normally close to atmospheric, the transmural pressure of the great veins at the thoracic inlet becomes negative, leading to their collapse which prevents any further increase in Q RV (flow-limitation). From this overall state of affairs, it results that the relationship between Q RV and RAP at constant MSFP has the shape depicted by curve 1 in Fig. 2b. Guyton has coined the term venous return curve for this relationship. His classical experiments in dogs where right ventricular bypass was used to uncouple venous return from cardiac output have provided a strong support for this model. In particular, the linearity of the venous return curve for values of RAP above P crit has been confirmedFootnote 1 [10]. The venous return curve intercepts the horizontal axis at a pressure value equal to MSFP. This statement implies that RAP equals MSFP in circulatory arrest, forming the basis for the experimental measurement of MSFP. At constant P crit and R v, any increase in MSFP, whether due to an augmentation of the total blood volume in the capacitance vessels or to a transfer of blood from the unstressed to the stressed volume (the latter often resulting from venoconstriction due to adrenergic stimulation), translates into an “rightward” shiftFootnote 2 of the venous return curve (Fig. 2b, curve 2). Conversely, hypovolemia, whether absolute or relative (i.e., reduced venous tone leading to increased venous compliance and transfer of blood from the stressed to the unstressed volume) would shift the venous return curve “leftwards” (not shown on Fig. 2b). Finally, let us note that the slope of the linear part above Pcrit is inversely related to R v (Fig. 2b, curve 3)Footnote 3 .

Fig. 2
figure 2

Interactions of venous return and cardiac function. a Magder’s representation of the circulatory system. Modified from [8], with permission. MSFP mean systemic filling pressure. Detailed explanations in the text (beginning of Sect. “Venous return curve”). b Venous return curves (later part of Sect. “Venous return curve”). c cardiac function curves (Sect. “Cardiac function curve”). d Guyton’s graphical analysis of cardiac output regulation (Sect. “Graphical analysis of cardiac output/venous return”). e Potential effects of generalized venoconstriction on cardiac output (last paragraph of Sect. “Graphical analysis of cardiac output/venous return”). In panels b–e, RAP designates right atrial pressure relative to atmosphere

Cardiac function curve

In Guyton’s representation, the cardiac function curve is a plot of cardiac output against the intramural RAP (Fig. 2c). As such, it is “a composite function curve for the entire segment of the circulatory system between the input of the heart and its output, including, of course, both sides of the heart as well as the pulmonary circulatory system” (Chap. 8 of [6]). The position of the cardiac function curve depends on, and in fact integrates, all aspects of cardiac pump performance, including the diastolic function, contractility and afterload of both ventricles, as well as heart rate.

Let us insist that, despite transmural pressure being a better index of cardiac preload, the RAP depicted in Fig. 2c is intramural pressure, i.e., measured relative to atmosphere, as is the case for the venous return curve in Fig. 2b. Why this is so will become clear in an instant.

Graphical analysis of cardiac output/venous return

Both the venous return and the cardiac function curves express flow as a function of intramural RAP, and may therefore be superimposed on the same plot (Fig. 2d). Over any time frame longer than a few heartbeats, cardiac output must equal venous return, i.e., the heart can only pump what it receives from the periphery. Thus, systemic blood flow is indicated by the intersection of the cardiac output and venous return curves, which is designated as the operating point of the circulatory system for specific states of vascular and cardiac function. In spite of its simplicity, this representation has considerable heuristic value for the integrated analysis of cardiovascular events. For example, an instantaneous increase in cardiac output cannot influence MSFP because of the large compliance of capacitance vessels. Therefore, the only way that an augmentation of ventricular performance may cause a steady increase of venous return is by lowering RAP (Fig. 2d, operating point displaced from a to b). When RAP decreases below P crit, the operating point becomes located on the horizontal part of the venous return curve, so that circulatory flow becomes independent of cardiac function (Fig. 2d, point c) although it may increase if peripheral determinants of venous return change in the appropriate direction (for example if MSFP is augmented and the venous return curve is shifted “rightwards” following i.v. fluid administration, Fig. 2d, point d).

We have so far ignored potential changes in the resistance to venous return (R v). For example, venoconstriction induced by a sympatho-adrenergic discharge may both reduce venous compliance (thus increasing MSFP) and augment R v (thus “flattening” the oblique part of the venous return curve, see end of Sect. “Venous return curve” and Fig. 2b). The net impact on the position of the operating point, and thus on cardiac output, then depends on the balance between these two conflicting influences, as shown in Fig. 2e, where the plain curves represent the baseline state (operating point a), and the dashed curves, the effects of sympatho-adrenergic stimulation, assuming either a small (point e) or large (f) increase in R v for the same change in MSFP.

Three caveats

The graphical analysis presented above is conceptually quite useful, as we hope to demonstrate in subsequent sections. However, it may be a source of confusion if incompletely understood. The first confusion arises if it is not clearly noted that the intramural RAP relative to atmosphere is being used throughout. Thus, the Guytonian cardiac function curve is shifted to the left or to the right by a decrease or an increase in extramural (intrathoracic) pressure (Sect. “Contact interactions of the heart and lungs” in Part I and Sect. “Effects of PEEP on cardiac output” in Part II). The second confusion relates to the intellectual habit of considering a variable plotted in abscissa as necessarily independent. For example, it is commonly considered that i.v. fluid loading increases cardiac filling pressures (thus RAP), hence cardiac preload, hence cardiac output. Considering Fig. 2b which predicts that venous return should decrease with a increasing RAP, one might feel faced with a conundrum. The solution is of course that vascular filling first increases MSFP, which augments venous return, which increases cardiac preload and filling pressures. In such conditions, MSFP must always increase more than RAP does,Footnote 4 otherwise venous return could not be augmented. In general, RAP can only be independently controlled if the heart is uncoupled from venous return by interposing an external bypass circuit, as Guyton (Sect. “Venous return curve”) and others (Sect. “Contact interactions of the heart and lungs”, Figs. 3, 4) have done experimentally. In the intact organism, by contrast, RAP is no more an independent variable than are venous return or cardiac output. The third confusion consists in a semantic ambiguity of the expression “venous return”, which designates either the flow of venous return (in liters of blood per minute) or the physiological function depicted by the venous return curve. In the case of the heart, such ambiguity does not exist (i.e., usual terminology always clearly distinguishes heart function from cardiac output).

Fig. 3
figure 3

Effects of PEEP on the venous return curve in closed-chest canines. Dogs were anesthetized, intubated and ventilated. By ways of cannulas placed in both venae cavae, venous return was drained through Starling resistors (i.e., collapsible tubes enclosed in an airtight chamber to allow control of their extramural pressure), and pumped back into the right atrium (RA) with a roller pump (upper part of the figure). The pump rotating speed was set so as to maintain a negative intramural pressure within the collapsible tubes. In such conditions, the pump forwarded into the heart and circulation whatever amount of blood came through the Starling resistors, independent of heart function (i.e., venous return would be uncoupled from heart function). By adjusting the extramural pressure around the collapsible tubes, outflow pressure for venous return (the equivalent of right atrial pressure in the intact organism) could be set at any desired value, and the resulting venous outflow was then measured. In this way, the venous return curves shown in the lower part of the figure were constructed at two different PEEP levels, after surgical closure of the chest (from [25] with permission). These data are discussed in detail in Sect. “Respiration and venous return”. Outflow pressure is measured relative to atmosphere

Fig. 4
figure 4

Effects of PEEP on the cardiac function curve in closed-chest canines. Dogs were anesthetized, intubated and ventilated. Venous return was drained through caval cannulae into a large volume reservoir (2 l), then forwarded to the right atrium (RA) by means of a roller pump (upper part of the figure). Contrary to the setup shown in Fig. 3, there were no Starling resistors in the circuit (the compliant tube served only to reduce the pressure oscillations generated by the pump). Here, the controlled variable was pump output, which determined ventricular filling. Changing pump output would induce concomitant changes in cardiac output and right atrial pressure. Due to the buffering effect of the reservoir, these modifications would not depend on the particular value of venous return flow (i.e., cardiac function would be uncoupled from venous return function). In this way, cardiac output curves were constructed at different PEEP levels, after surgical closure of the chest (lower part of the figure). Surface pressure over the heart was measured with specialized flat sensors, to allow the calculation of right atrial transmural pressure. Left atrial pressure, also measured in these experiments, is not shown for simplicity (from [28] with permission). Right atrial pressure is measured relative to atmosphere in the left-hand part, and relative to extramural pressure in the right-hand part of the figure These data are discussed in detail in Sect. “Contact interactions of the heart and lungs”

Cardiorespiratory interactions in transient versus steady state

Whenever considering the interactions of respiration with the function of other organs, it is important to bear in mind the distinction between transient and steady state effects [12]. Transient effects refer either to periodic changes induced by the inspiratory/expiratory cycle (phasic effects) or to unsustained effects of various respiratory maneuvers. Due to the short duration, their mechanisms are of a primarily mechanical nature. Steady state effects indicate the impact of sustained alterations of respiratory conditions, such as the institution of positive end-expiratory pressure (PEEP) in a mechanically ventilated patient. Steady state effects depend both on mechanical and on neurohumoral factors (for example the neural regulation of venous compliance, resistance to venous return and cardiac contractility, Fig. 2e).

A caveat is here in order. In the steady state, venous return is methodologically very hard to dissociate from cardiac function. Again, the construction of a complete venous return curve is impossible without bypassing the right ventricle with an external circuit, and a similar remark applies to the cardiac function curve (Sects. “Venous return curve”, “Cardiac function curve”). For these reasons, there is an understandable lack of human data on steady state cardiorespiratory interactions. Furthermore, most available experimental studies have been carried out in animals with normal lungs, and have focused on the effects of high PEEP levels (≥15 cm H2O) while ignoring those related to tidal inflation. Extrapolation of such data to the clinical setting must therefore be done with some caution.

Respiration and venous return

Transient effects of practical importance will be discussed in later Sects. (6.1–6.4 in Part II). Here, we shall restrict ourselves to the description of steady state effects. Most of the available relevant studies have been focused on the impact of a steady increase in intrathoracic pressure as effected by positive end-expiratory airway pressure (PEEP).

For decades, it has been conventional wisdom that an essential mechanism whereby PEEP depresses cardiac output consists in the transmission of the elevated mean intrathoracic pressure into the right atrium, which raises intramural RAP and so decreases the pressure gradient for venous return [6, 13]. The assumption that other determinants of venous return remain unaltered by PEEP was implicit in this reasoning, but is now contradicted by several lines of evidence.

Two independent groups have reported that PEEP levels of up to 15 [14] or 20 cm H2O [15], while clearly depressing cardiac output, caused identical increases in RAP and MSFP, so that the pressure gradient for venous return was invariant, a finding confirmed more recently in humans [16]. The mechanisms involved a transfer of capacitance blood from the unstressed to the stressed volume [15], due to enhancement of venous tone mediated in part by sympatho-adrenergic activation [14], akin to changes noted earlier in hypotension produced by hemorrhage [17] or local manipulation of the carotid sinus [18, 19]. Furthermore, the depression of cardiac output by PEEP was amplified by alpha adrenergic blockade [20]. These data indicate that the reflex matching of the increased RAP by an equivalent increase in MSFP is an important facet of cardiovascular adaptation to PEEP. Part of the PEEP-induced augmentation of MSFP could also be due to purely mechanical factors, such as the translocation of blood from the pulmonary to the systemic capacitance vessels [2123] or the increase in abdominal pressure (due to diaphragmatic descent) which compresses the splanchnic part of the venous reservoir [24].

Although the MSFP–RAP gradient remained constant, cardiac output was clearly depressed in the aforementioned studies, implying that PEEP modified either the resistance to venous return (R v) or the critical pressure (P crit). This issue was handled in further experiments by Fessler and coworkers [25], who constructed true venous return curves with and without 10 cm H2O PEEP in closed-chest dogs equipped with a external circuit which bypassed the right ventricle. The main results of this unique study are shown in Fig. 3; PEEP somewhat flattened the portion of the curve to the right of the critical point indicating slightly augmented values of R v, as also found by Nanas et al. [15]. PEEP also increased P crit and sharply depressed the plateau, indicating a decrease in the maximal value of venous return. These effects might be understood if expansion of the lung by PEEP distorted venous geometry, for example, at the entrance of the venae cavae into the thorax [26], or further upstream in the portal circulation (i.e., compression of the liver by diaphragmatic descent [27]).

In short, the available evidence indicates that PEEP interferes with systemic venous return in a manner more complicated than by just raising RAP. It is important to note that all the aforementioned actions of PEEP must be modulated by the volemic status, although detailed experimental data are scant on this point. In particular, hypovolemia is likely to blunt or even entirely prevent the compensatory rise in MSFP. Conversely, repletion of intravascular volume might make the systemic veins less susceptible to compression, thus minimizing the effects of PEEP on R v and P crit, as shown in the case of the porcine hepatic circulation [27].

Respiration and cardiac function

Contact interactions of the heart and lungs

Considering that RAP is measured relative to atmosphere and assuming that respiration should not alter the relationship of transmural filling pressure to cardiac output, Guyton predicted that changes in intrathoracic pressure (ITP) would cause parallel shifts of the cardiac function curve (i.e., cardiac output plotted against intramural RAP) along the pressure axis (Chap. 24 of [6]). This hypothesis was verified by Marini and coworkers [28] (Fig. 4, lower left) in anesthetized, mechanically ventilated canines, using a bypass circuit from the great veins to the right atrium in order to control the inflow of blood into the heart (Fig. 4, upper part). To allow the most accurate measurement of transmural filling pressures, epicardial fluid-filled flat sensors were positioned over the left and right ventricles. In these experiments, the plots of cardiac output versus transmural RAP or left atrial pressure (LAP) were not modified by PEEP levels of up to 15 cm H2O, indicating little modulation of ventricular function per se by these ventilatory conditions, consistent with results by other investigators [29] (Fig. 4, lower right). In the former study, there was evidence that lung inflation “compressed the heart”, i.e., imposed a progressive external constraint mediated by local surface pressure on the epicardium, which increased with increasing heart volume. This constraint appeared local and independent of global ITP, since it was not removed by opening the chest and could be elicited by the selective inflation of basal lung segments [30]. The concept of heart compression by the inflated lung is consistent with the small heart size typically observed on chest films in acute asthma. Via dynamic hyperinflation, it could also explain the increase in RAP and pulmonary artery occlusion pressure (PAOP) observed on mild exercise as well as voluntary hyperventilation in patients with obstructive lung disease uncomplicated by pulmonary hypertension or overt heart failure [31].

Ventricular interdependence and left ventricular diastolic function

The right (RV) and left ventricle (LV) are mechanically coupled, because they share a common septum and circumferential fibers, and the expansion of both is constrained by a common pericardium. For these reasons, the diastolic filling of one chamber has direct influence on the geometry and stiffness of the other, a phenomenon known as direct (or parallel) ventricular diastolic interdependence [32].

With phasic respiration, the end-diastolic volumes of both ventricles tend to change in opposite directions [33]. Spontaneous inspiration augments venous return, thus increasing RV filling, which in turn makes the LV stiffer, thus impeding its filling [33, 34]. Lung inflation with positive airway pressure tends to act in an inverse fashion [35, 36]. These mechanisms imply phasic changes in the diastolic properties of the ventricles. They underly in part the respiratory fluctuations of arterial pressure to be described below, although an equally important role is being played in that respect by series interdependence (the propagation of changes in RV output to LV output, due to the series arrangement of both ventricles) [37].Footnote 5

Encroachment of a dilated RV on LV filling as a steady, rather than transient effect may result from extreme hyperinflation, such as associated with PEEP levels in excess of 20 cm H2O [40], or when more moderate increases of ITP and lung volume are superimposed on either an obstructed pulmonary circulation or a failing RV [41]. In these cases, the primum movens is the acute increase in RV afterload, with consequent RV dilatation.

Ventricular afterload

Defined as the force opposing ejection,Footnote 6 ventricular afterload is represented by the level of transmural pressure, in the course of systole, within either the aortic root (LV afterload) or the pulmonary artery trunk (RV afterload) The transmural rather than the intraluminal pressure must be considered [44, 45], because these great vessels as well as the ventricles are exposed to an extramural pressure (i.e., ITP) which is usually non atmospheric. The mechanisms whereby respiration interacts with LV and RV afterload are different.

LV afterload

At the onset of spontaneous inspiration, the intraluminal pressure in the aortic root decreases less than does ITP, due to the connection of this vessel with extrathoracic arteries. As a result, aortic transmural pressure increases. With spontaneous breathing therefore, LV afterload is greater in inspiration than in expiration [4648]. A symmetrical chain of events leads to a reduced LV afterload in the course of a transient increase in ITP, such as with positive pressure inflation of the lungs. Steady increases in ITP, as effected with PEEP, similarly unload the LV with potentially beneficial consequences in presence of left heart failure, as described in greater detail below (Sect. “Effects of PEEP on cardiac output” in Part II). Conversely, patients with obstructive sleep apnea have bouts of greatly negative ITP which increase LV afterload, thus contributing to LV hypertrophy [49].

RV afterload

A seminal paper by Permutt [50] shows that RV afterload is highly dependent on and increases with the proportion of lung tissue in West zone 1 or 2, as opposed to zone 3 conditions. Zones 1 or 2 exist whenever the extraluminal pressure of alveolar capillaries (which is close to alveolar pressure, P A) exceeds the intraluminal value, leading to vessel compression. In zone 3 by contrast, intraluminal capillary pressure exceeds P A. For hydrostatic reasons, zones 1 and 2 are more likely to occur in nondependent parts of the lung. Furthermore, respiratory changes in the intraluminal pressure of alveolar capillaries tend to track changes in ITPFootnote 7 and thus to decrease more than does P A during a spontaneous inspiration and to increase less than does PA on inflation of the lung with positive pressure. Thus, any increase in lung volume, whether in the context of spontaneous [51] or mechanically assisted breathing [45], has the potential to promote the formation of zones 1 and 2 at the expense of zone 3, and thus to increase RV afterload. These considerations are of high clinical relevance, notably concerning the possible induction or aggravation of acute cor pulmonale by mechanical ventilation, as described below (Sect. “Mechanical ventilation and acute cor pulmonale” in Part II).

Myocardial contractility

Some studies have indicated that lung inflation by PEEP could trigger the humoral release of one or several cardiodepressor agents [52, 53]. However, as we have already seen, biventricular Starling curves were not depressed by PEEP (Fig. 4, right). Furthermore, work in both animals and humans, using various methodologies to measure the size of cardiac chambers, consistently failed to indicate any influence of PEEP on the relationship of ventricular preload to stroke output, stroke work, or end-systolic ventricular pressure [40, 41, 54, 55]. Finally, experimental studies have shown that end-systolic elastance, a recognized load-invariant index of contractility, remained constant at levels of PEEP up to 15 cm H2O [55, 56], even when possible adrenergic reflexes were suppressed with beta-blockade [55]. In short, a steady state increase in ITP and lung volume, as effected by PEEP, does not appear to directly depress myocardial contractility.

Myocardial perfusion and ischemia

Whether in specific conditions PEEP could indirectly alter myocardial contractility by inducing myocardial ischemia remains largely unresolved [57, 58]. Many studies have indicated that clinically relevant levels of PEEP can decrease myocardial blood flow. In the LV, afterload and preload are concomitantly reduced, leading to diminished systolic wall stress and O2 demand, with an unpredictable net effect on the adequacy of myocardial O2 supply [59, 60]. In a dog model of acute ischemic LV failure induced by embolization of the left coronary artery with microspheres, the institution of 15 cm H2O PEEP had no impact on ischemic myocardial metabolism assessed by lactate extraction [61]. In the RV by contrast, PEEP has a greater potential to upset the balance between O2 supply and demand, due to its ability to increase afterload. Indeed, two canine studies have shown that the institution of PEEP aggravates the RV dysfunction induced by ligation of the right coronary artery [41, 62]. In one of them, PEEP also caused an extension of myocardial necrosis in the area at risk [62].

There is evidence that negative ITP can induce or aggravate LV myocardial ischemia, likely by increasing LV afterload in the presence of insufficient coronary reserve. Scharf and colleagues [63] found that patients with coronary artery disease developed LV dyskinesis during a Mueller maneuver with an inspiratory effort of −20 to −30 cm H2O. These changes were not seen in patients with normal coronary arteries. Negative ITP of this magnitude can occur during weaning from mechanical ventilation, at times inducing LV dysfunction possibly due to LV ischemia and responsible for weaning failure (Part II, Sect. “Weaning failure from cardiovascular origin”).