Abstract
PURPOSE: The aim of this study was to evaluate the reliability of intraoperative laser-Doppler measurements in predicting the occurrence of anastomotic leak in patients with colorectal cancer undergoing stapled straight anastomosis to the rectum. METHODS: A prospective study was undertaken on 55 patients with rectal cancer or distal sigmoid cancer programmed for elective curative surgery. In all patients transmural colonic blood flow was measured by laser-Doppler flowmetry technique before bowel manipulation (baseline measurement) and after vascular ligation and division. Comorbidities at admission, intraoperative events, associated surgical procedures, and clinical outcome were tested for any association with anastomotic leak. RESULTS: Postoperative mortality was 1.8 percent (1/55 patients), and the overall morbidity was 21.3 percent. Anastomotic leak occurred in eight patients (14.5 percent). After colonic division a blood flow reduction at the rectal stump was observed in 42 patients (76.3 percent) as compared with baseline measurement. The mean rectal stump flow reduction was 6.2 percent in patients without anastomotic leak, whereas in patients who developed anastomosis breakdown it was 16 percent (P<0.001). Mean proximal stump flow reduction was 5.1 percent in the uncomplicated patients, whereas in patients who had an anastomosis breakdown it was 12.9 percent (P<0.01). A positive linear correlation was found between decrease in blood flow and rate of anastomotic leak. CONCLUSION: Blood flow reduction at the rectal stump is associated with an increased risk of anastomotic leak.
Similar content being viewed by others
References
Irvin TT, Goligher JC. Aetiology of disruption of intestinal anastomoses. Br J Surg 1973;60:461–4.
Mileski WJ, Joehl RJ, Rege RV, Nahrwold DL. Treatment of anastomotic leakage following low anterior colon resection. Arch Surg 1988;123:968–70.
Antonsen HK, Kronborg O. Early complications after low anterior resection for rectal cancer using the EEA stapling device: a prospective trial. Dis Colon Rectum 1987;30:579–83.
Schrock TR, Deveney CW, Dunphy JE. Factors contributing to leakage of colonic anastomoses. Ann Surg 1973;177:513–8.
Vignali A, Fazio VW, Lavery IC, et al. Factors associated with the occurrence of leaks in stapled rectal anastomoses: A review of 1.014 patients. J Am Coll Surg 1997;185:105–13
Chung RS. Blood flow in colonic anastomoses. Ann Surg 1987;206:335–9.
Johansson K, Ahn H, Lindhagen J, Lundgren O. Tissue penetration and measuring depth of laser doppler flow-metry in the gastrointestinal application. Scand J Gastroenterol 1987;22:1081–8.
Shandall AR, Lownders RH, Young HL. Colonic anastomotic healing and oxygen tension. Br J Surg 1985;72:606–9.
Saklud M. Grading of patients for surgical procedures. Anesthesiology 1941;2:281–5.
Braga M, Gianotti L, Vignali A, Cestari A, Bisagni P, Di Carlo V. Artificial nutrition after major abdominal surgery: impact of route of administration and composition of the diet. Crit Care Med 1998;26:24–30.
Ahn H, Lindhagen J, Lundgren O. Measurement of colonic blood flow with laser doppler flowmetry. Scand J Gastroenterol 1986;21:871–80.
Krohg Sørensen K, Lunde OC. Perfusion of the human distal colon and rectum evaluated with endoscopic laser doppler flowmetry. Methodologic aspect. Scand J Gastroenterol 1993;28:104–8.
Hanley JL, McNeil BJ. The meaning and the use of the area under receiving operating characteristics (ROC) curve. Radiology 1982;143:29–36.
Novell JR, Lewis. Peroperative observation of marginal artery bleeding: a predictor of anastomotic leakage. Br J Surg 1990;77:137–8.
Dworkin MJ, Allen Mersh TG. Effect of inferior mesenteric artery ligation of blood flow in the marginal-artery dependent sigmoid colon. J Am Coll Surg 1996;183:357–360.
Sheridan WG, Lowndes RH, Young HL. Tissue oxygen tension as a predictor of colonic anastomotic healing. Dis Colon rectum 1987, 30:867–71.
Krohg Sørensen K, Line PD, Kvernebo K. Laser doppler flux and tissue oxygen tension as indicator of colonic perfusion in pigs. Eur J Surg 1993;159:293–9.
Kashiwagi H. The lower limit of tissue blood flow for safe colonic anastomosis: an experimental study using laser doppler velocimetry. J Surg Today 1993;23:430–8.
Hallböök O, Johansson K, Sjödahl R. Laser doppler blood flow measurement in rectal resection for carcinoma: comparison between straight and colonic J pouch reconstruction. Br J Surg 1996;83:389–92.
Fasth S, Hulten L, Lundgren O, Nordgren S. Vascular response to mechanical stimulation of the gut mucosa of the cat colon. Acta Physiol Scand 1977;101:98–104.
Johansson K, Ahn H, Lindhagen J. Intraoperative assessment of blood flow and tissue viability in small bowel ischemia by laser Doppler flowmetry. Eur J Surg Suppl 1989;155:341–6.
Hulten L. Inadequate local blood supply—a common cause of anastomotic leakage after anterior resection? Theor Surg 1990;5:16–8.
Author information
Authors and Affiliations
About this article
Cite this article
Vignali, A., Gianotti, L., Braga, M. et al. Altered microperfusion at the rectal stump is predictive for rectal anastomotic leak. Dis Colon Rectum 43, 76–82 (2000). https://doi.org/10.1007/BF02237248
Issue Date:
DOI: https://doi.org/10.1007/BF02237248