Abstract
Purpose
This study was designed to determine if leaving a stylet in the left Bronch-Cath® endobronchial tube (DLT) for the entire intubating procedure improves the accuracy of placement on the initial attempt, without introducing complications.
Methods
Sixty ASA 1–3 patients were randomized to one of two groups. In Group 1 (n − 30), the stylet was retained for the entire intubation procedure and in Group 2 (n = 30), the stylet was removed once the bronchial cuff had passed the vocal cords. In both groups, the DLT was turned 110° counterclockwise and advanced until resistance was encountered. Placement was assessed by auscultation and fibreoptic bronchoscopy (FOB). After surgery, the DLT was replaced by a single-lumen endotracheal tube. The thoracic surgeon (blinded to the method of intubation, and using a FOB) assessed the appearance of the tracheobronchial mucosa.
Results
The two groups were similar with respect to sex, height, weight, DLT size, surgeon and expertise of the laryngoscopist. When the stylet was retained, the DLT was correctly placed 60% of the time compared with 17%, if the stylet was removed, (P = 0.001). Seven out of 30 DLTs in Group 2 were initially placed into the right mainstem bronchus, (P = 0.005). The average time to confirmation of correct tube placement by FOB was increased in Group 2, (P = 0.01). Although the observed incidence of left bronchial, mucosal petechiae and erythema was greater in Group 2, this was not statistically significant, (P = 0.063).
Conclusion
Retaining the stylet for the entire intubation procedure allows for a more rapid, accurate placement of the DLT without increasing the incidence of tracheobronchial mucosa injury.
Résumé
Objectif
Cette étude visait à déterminer si le fait de laisser un guide dans un Bronch-Cath® endobronchique gauche (TEG) pendant toute la manoeuvre d’intubation assurait l’exactitude de la position dès la première tentative et ne provoquait pas de complications.
Méthode
Soixante patients ASA 1—3 ont été répartis aléatoirement en deux groupes. Dans le groupe 1 (n = 30), le guide est demeuré en place pendant la manoeuvre d’intubation, et dans le groupe 2, le guide a été enlevé dès que le tube êut passé les cordes vocales. Dans les deux groupes, le TEG a été pivoté à 110° dans le sens contraire aux aiguilles d’une montre et avancé jusqu’à la rencontre d’une résistance. La position du tube a été vérifiée par auscultation et bronchofibroscopie. Après la chirurgie, le TEG a été remplacé par une tube ordinaire. Le chirurgien thoracique (qui ignorait la méthode d’intubation et utilisait un bronchofibroscope) a évalué la muqueuse trachéobronchique selon son apparence.
Résultats
Les deux groupes étaient identiques quant au sexe, la taille, le poids, le diamètre du tube, le chirurgien et la compétence du laryngoscopiste. Avec un guide en place, le TEG a été correctement installé 60% du temps comparativement à 17% avec retrait du guide (P = 0,001). Dans le groupe 2, dans sept cas sur 30, le TEG a été placé initialement dans la bronche souche gauche (P = 0,005). Le délai de confirmation de l’exactitude de la position vérifiée par bronchofibroscope a été prolongé dans le groupe 2 (P = 0,01). L’incidence d’érythème et de pétéchies de la muqueuse bronchique, bien que plus élevée dans le groupe 2, n’était pas significative (P = 0,063).
Conclusion
Le maintien du guide pendant la manoeuvre d’intubation du TEG permet une mise en position rapide et précise sans augmentation de l’incidence de lésions muqueuses trachéobronchiques.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Alliaume B, Coddens J, Deloof T. Reliability of auscultation in positioning of double-lumen endobronchial tubes. Can J Anaesth 1992; 39: 687–90.
Enhrenwerth J. Pro: Proper positioning of a double-lumen endobronchial tube can only be accomplished with endoscopy. J Cardiothorac Vasc Anesth 1988; 2: 101–4.
Smith GB, Hirsch NP, Enhrenwerth J. Placement of double-lumen endobronchial tubes. Br J Anaesth 1986; 58: 1317–20.
Lewis JW, Serwin JP, Gabriel FS, Bastanfar M, Jacobsen G. The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures. J Cardiothorac Vasc Anesth 1992; 6: 705–10.
Slinger PD. Fiberoptic bronchoscopic positioning of double-lumen tubes. J Cardiothorac Vasc Anesth 1989; 3: 486–96.
Benumof JL. Anaesthesia for Thoracic Surgery. Philadelphia: WB Saunders Company, 1987: 223–59.
Benumof JL. The position of a double-lumen tube should be routinely determined by fiberoptic bronchoscopy (Editorial). J Cardiothorac Vasc Anesth 1993; 7: 513–4.
Brodsky JB. Con: Proper positioning of a double-lumen endobronchial tube can only be accomplished with the use of endoscopy. J Cardiothorac Vasc Anesth 1988; 2: 105–9.
Hannallah MS, Benumof JL, McCarthy PO, Liang M. Comparison of three techniques to inflate the bronchial cuff of left Polyvinylchloride double-lumen tubes. Anesth Analg 1993; 77: 990–4.
Hasan A, Low DE, Ganado AL, Norton R, Watson DCT. Tracheal rupture with disposable polyvinylchloride double-lumen endotracheal tubes. J Cardiothorac Vasc Anesth 1992; 6: 208–11.
Wilson RS. Endobronchial intubation.In: Kaplan JA (Ed.). Thoracic Anaesthesia, 2nd ed. New York: Churchill-Livingstone Inc, 1991: 371–88.
Burton NA, Watson DC, Brodsky JB, Mark JBD. Advantages of a new polyvinyl chloride double-lumen tube in thoracic surgery. Ann Thorac Surg 1983; 36: 78–84.
Brodsky JB, Shulman MS, Mark JBD. Malposition of leftsided double-lumen endobronchial tubes. Anesthesiology 1985; 62: 667–9.
Burton NA, Fall SM, Lyons T, Graeber GM. Rupture of the left main-stem bronchus with a Polyvinylchloride double-lumen tube. Chest 1983; 83: 928–9.
Wagner DL, Gammage GW, Wong ML. Tracheal rupture following the insertion of a disposable double-lumen endotracheal tube. Anesthesiology 1985; 63: 698–700.
Yahogi N, Furuya H, Matsui J. Improvement of the left broncho-cath double-lumen tube (Letter). Anesthesiology 1994; 81: 781–2.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Lieberman, D., Littleford, J., Horan, T. et al. Placement of left double-lumen endobronchial tubes with or without a stylet. Can J Anaesth 43, 238–242 (1996). https://doi.org/10.1007/BF03011741
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03011741