Abstract
Tracheal intubation under direct vision using a laryngoscope can be challenging and difficult even in experienced hands. Transillumination of the soft tissues of the neck using a lightedstylet (lightwand) is one of many effective alternative intubating techniques developed during the past several decades. While many versions of lightwand have been available, each has its limitations. A newly developed lightwand (Trachlight™) has incorporated many design modifications. It has a brighter bulb, permitting intubation under ambient light in most cases. A retractable stiff wire within the wand adds flexibility to facilitate both oral and nasal intubation. The flexible wand also allows visual (transillumination) guide to proper placement of the tip of the tracheal tube in the trachea. The Trachlight™ does have some limitations. It is a light-guided technique in which there is no direct visualization of the upper airway structures. It should be avoided in patients with known anatomical abnormalities of the upper airway and used with caution in patients in whom transillumination of the anterior neck may not be achieved adequately. As with any intubating technique, successful intubation using the Trachlight™ relies on the preparation of the patient and the operator’s skill and experience.
Résumé
Même entreprise par des personnes expérimentées, l’intubation sous vision directe avec un laryngoscope peut être laborieuse. La transillumination des tissus du cou avec un mandrin lumineux constitue une des techniques de rechange développées au cours des dernières décennies. Bien que plusieurs versions du mandrin lumineux soient disponibles, elles ont toutes leurs limites. Un nouveau mandrin lumineux (Trachlight™) incorpore plusieurs modifications au design original. L’éclairage est intense, ce qui permet l’intubation à la lumière ambiante dans la plupart des cas. Un stylet rétractile à l’intérieur du mandrin ajoute de la flexibilité ce qui facilite l’intubation orale et nasale. Le mandrin flexible permet aussi de guider visuellement (par transillumination) le bout de la canule endotrachéale dans la trachée. Le Trachlight™ a aussi ses limites. Il s’agit d’une technique d’orientation par la lumière qui ne perm et pas de visualiser directement les structures des voies aériennes supérieures. Elle devrait être évitée dans les cas d’anomalies connue de l’anatomie des voies aériennes supérieures et utilisée avec prudence lorsque la transillumination des structures antérieures du cou ne peut être réalisée correctement. Comme pour toutes les techniques d’intubation, le succès dépend de la préparation du patient, et de l’expérience et de l’habileté de l’intubateur.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Latto IP. Management of difficult intubation.In: Latto IP, Rosen M (Eds.). Difficulties in Tracheal Intubation. London: Baillière Tindall, 1987: 99–141.
Yamamura H, Yamamoto T, Kamiyama M. Device for blind nasal intubation. Anesthesiology 1959; 20: 221.
Vollmer TP, Stewart RD, Paris PM, Ellis D, Berkebile PE. Use of a lighted stylet for guided orotracheal intubation in the prehospital setting. Ann Emerg Med 1985; 14: 324–8.
Ellis GE, Jakymec A, Kaplan RM, et al. Guided orotracheal intubation in the operating room using a lighted stylet: a comparison with direct laryngoscopic technique. Anesthesiology 1986; 64: 823–6.
Ainsworth QP, Howells TH. Transilluminated tracheal intubation. Br J Anaesth 1989; 62: 494–7.
Weis FR, Hatton MN. Intubation by use of the light wand: experience in 253 patients. J Oral Maxillofac Surg 1989; 47: 560–77.
Stewart RD, LaRosee A, Kaplan RM, Ilkhanipour K. Correct positioning of an endotracheal tube using a flexible lighted stylet. Crit Care Med 1990; 18: 97–9.
Hung OR, Pytka S, Morris IR, et al. Clinical trial of a new lightwand device (Trachlight™) to ntubate the trachea. Anesthesiology. (in press)
Stone DJ, Stirt JA, Kaplan MJ, McLean WC. A complication of lightwand-guided nasotracheal intubation. Anesthesiology 1984; 61: 780–1.
Debo RF, Colonna D, Dewerd G, Gonzalez C. Cricoarytenoid subluxation: complication of blind intubation with a lighted stylet. Ear Nose Throat J 1989; 68: 517–20.
Author information
Authors and Affiliations
Additional information
Supported, in part, by a Grant from Laerdal Research Foundation, Armonk, NY.
Rights and permissions
About this article
Cite this article
Hung, O.R., Stewart, R.D. Lightwand intubation: I — A new lightwand device. Can J Anaesth 42, 820–825 (1995). https://doi.org/10.1007/BF03011186
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03011186