Abstract
Muscle mass is a determining factor in skeletal muscle function and is affected by inactivity, immobilization, disease, and aging. The aim of this study was to develop an objective and timeefficient method to quantify the volume and cross-sectional area of human calf muscles using three-dimensional magnetic resonance images. We have estimated the errors incurred in muscle volume measurements arising from artifacts known to occur in magnetic resonance imaging (MRI). The largest source of error was due to partial volume effects, which resulted in overestimation of phantom volumes ranging from 145 to 900 cc by 6% to 13%. The magnitude of this effect has been shown to increase with decreasing object size and decreasing spatial resolution. We have presented a straightforward correction for this effect, which has reduced the volume measurement error to less than 4% for all cases. Through the use of computer simulations, the correction algorithm has been shown to be independent of object shape and orientation. To reduce user subjectivity, a semiautomated computer program has been developed to segment MRI data for particular muscle groups. Images from seven human subjects were analyzed by the program, yielding muscle volumes of 154.2±23.2, 281.2±35.8, and 432.2±83.7 for the lateral gastrocnemius, medial gastrocnemius, and soleus, respectively.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
Bassey EJ, Fiatarone MA, O'Neill EF, Kelly M, Evans WJ, Lipsitz LA (1992) Leg extensor power and functional performance in very old men and women.Clin Sci 82:321–327.
Veldhuizen JW, Verstappen FT, Vroemen JP, Kuipers H, Greep JM (1993) Functional and morphological adaptations following four weeks of knee immobilization.Int J Sports Med 14: 283–287.
Evans WJ (1995) Effects of exercise on body composition and functional capacity of the elderly.J Gerontol 50A: 147–150.
Wolfson L, Judge J, Whipple R, King M (1995) Strength is a major factor in balance, gait, and the occurrence of falls.J Gerontol 50A: 64–67.
Lexell J (1995) Human aging, muscle mass, and fiber type composition.J Gerontol 50A: 11–16.
Gibbs P, Buckley DL, Blackband SJ, Horsman A (1996) Tumour volume determination from MR images by morphological segmentation.Phys Med Biol 41: 2437–2446.
Tkach J, Haacke EM (1988) A comparison of fast spin echo and fast gradient field echo sequences.Magn Reson Imaging 6: 373–389.
Phoenix J, Betal D, Roberts N, Helliwell T, Edwards R (1996) Objective quantification of muscle and fat in human dystrophic muscle by magnetic resonance image analysis.Muscle Nerve 19: 302–310.
Weinberger E, Shaw D, White K, Winters W, Stark J, Nazar-Stewart V, Hinks R (1995) Nontraumatic pediatric musculoskeletal MR imaging: comparison of conventional and fast-spin-echo short inversion time inversion recovery technique.Radiology 194: 721–726.
Clarke LP, Velthuizen RP, Camacho MA, Heine JJ, Vaidyanathan M, Hall LO, Thatcher RW, Silbiger ML (1995) MRI segmentation: methods and applications.Magn Reson Imaging 13: 343–368.
Fukunaga T, Roy RR, Shellock FG, Hodgson JA, Edgerton VR (1996) Specific tension of human plantar flexors and dorsiflexors.J Appl Physiol 80: 158–165.
Kenedy DN, Filipek PA, Caviness VS (1989) Anatomic segmentation and volumetric calculations in nuclear magnetic resonance imaging.IEEE Trans Med Imaging 8: 1–7.
Johnson LA, Pearlman JD, Miller CA, Young TI, Thulborn KR (1993) MR quantification of cerebral ventricular volume using a semiautomated algorithm.Am J Neuroradiol 14: 1373–1378.
Lancaster JL, Eberly D, Alyassin A, Downs JH, Fox PT (1992) A geometric model for measurement of surface distance surface area, and volume from tomographic images.Med Phys 19: 419–431.
Alyassin AM, Lancaster JL, Downs JH, Fox PT (1994) Evaluation of new algorithms for the interactive measurement of surface area and volume.Med Phys 21: 741–752.
Hillel PG, Hastings DL (1993) A three-dimensional second-derivative surface-detection algorithm for volume determination on SPECT images.Phys Med Biol 38: 583–600.
Hughes SW, D'Arcy TJ, Maxwell DJ, Saunders JE, Ruff CF, Chiu WSC, Sheppard RJ (1996) Application of a new discreet form of gauss' theorem for measuring volume.Phys Med Biol 41: 1809–1821.
Wood ML, Henkelman RM (1985) Truncation artifacts in magnetic resonance imaging.Magn Reson Med 2: 517–526.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Elliott, M.A., Walter, G.A., Gulish, H. et al. Volumetric measurement of human calf muscle from magnetic resonance imaging. MAGMA 5, 93–98 (1997). https://doi.org/10.1007/BF02592238
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02592238