Summary
Dual-energy X-ray absorptiometry (DXA) was used to determine thein vivo bone mineral content (BMC) of lumbar vertebrae in 20 feral adult female cynomolgus macaques (Macaca fascicularis). The ash weight of the third lumbar vertebra (L3) was compared to the measured L3BMC of thein vivo DXA analyses. Correlation between the estimated L3BMC by DXA and the actual ash weight was significant (r=0.965,P<0.01); however, DXA methodology underestimated ash weight on the average of 6.2%. Correlation was significant between two sequentialin vivo DXA scans (r=0.988,P<0.001). Noninvasivein vivo DXA was a fast, precise, and effective method for measuring the lumbar BMC in female cynomolgus macaques.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Cann C, Genant H, Kolb F, Ettinger B (1985) Quantitative computed tomography for prediction of vertebral fracture risk. Bone 6:1–7
Riggs B, Wahner H (1982) Changes in bone mineral density of the proximal femur and spine with aging. J Clin Invest 70:716–723
Riggs BL, Melton LJ (1986) Involutional osteoporosis. N Engl J Med 314:1676–1677
Elders PJM, Netelenbos JC, Lips P, van Ginkel FC, van der Stelt PF (1988) Accelerated vertebral bone loss in relation to the menopause: a cross-sectional study on lumbar bone density in 286 women of 46 to 55 years of age. Bone Miner 5:11–19
Mazess RB, Barden HS (1988) Measurement of bone by dualphoton absorptiometry (DPA) and dual-energy x-ray absorptiometry (DEXA). Annal Chir Gynaecol 77:197–203
Jayo MJ, Weaver DS, Clarkson TB, Carlson CS, Welles EG, Rankin SE (1990) Surgical menopause causes a significant decrease in lumbar bone mineral and serum HDL-cholesterol in female cynomolgus macaques (abstract #431). J Bone Miner Res (suppl 2)5:S181
Ho CP, Kim RW, Schaffer MB, Sartoris DJ (1990) Accuracy of dual-energy radiographic absorptiometry of lumbar spine: cadaver study. Radiology 176:171–173
Mazess RB (1983) Noninvasive bone measurements. In: Kunin AS, Simons DJ (eds) Skeletal research: an experimental approach, vol 2. Academic Press, Orlando, pp 277–343
Jayo MJ, Weaver DS, Rankin SE, Kaplan JR (1990) Accuracy and reproducibility of lumbar bone mineral status determined by dual photon absorptiometry in live male cynomolgus macaques (Macaca fascicularis). Lab Anim Sci 40:266–269
Miller LC, Weaver DS, McAlister JA, Koritnik DR (1986) Effects of ovariectomy on vertebral trabecular bone in the cynomolgus monkey (Macaca fascicularis). Calcif Tissue Int 38:62–65
Norland Corporation (1990) Operator's manual for the Norland XR-26 x-ray bone densitometer
Isaia G, Musetta M, Salamano G, Carlevatto V, Molinatti GM (1988) Diagnostic notes—lumbar BMC reproducibility as evaluated by means of dual photon absorptiometry. Maturitas 10:59–63
Peppler W, Mazess RB (1981) Total body bone mineral and lean body mass by dual-photon absorptiometry. Calcif Tissue Int 33:353–359
Wahner HW, Dunn WL, Mazess RB, Towsley M, Lindsay R, Markhard L, Dempster D (1985) Dual-photon Gd-153 adsorptiometry of bone. Radiology 156:203–206
Mazess RB, Vetter J, Weaver DS (1987) Bone changes in oophorectomized monkeys: CT findings. J Comput Assist Tomogr 11:302–305