Abstract
A colorimetric microassay is described for the determination of lipid hydroperoxides. Hydroperoxides are reacted with potassium iodide in the presence of an acid catalyst and liberated iodine is measured. Aluminum chloride, an alcohol-soluble Lewis acid, is used as catalyst. Liberated iodine is measured colorimetrically at 560 nm after addition of starch in 0.01 N hydrochloric acid. The range of the measurement was 0.05–0.5 μmol of hydroperoxides.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Lea, C.H., Proc. Soc. London Ser. B, 108:175 (1931).
Wheeler, D.H., Oil Soap (Chicago) 9:89 (1932).
The Standard Methods of Jpn. Oil Chem. Soc. 2.4.12–71.
Lips, A., R.A. Chapman and W.D. McFarlane, Oil Soap (Chicago) 20:240 (1943).
Chapman, R.A., and K.M. Mackay, J. Am. Oil Chem. Soc. 26:360 (1949).
Stine, C.M., H.A. Harland, S.T. Caulter and R. Jeness, J. Dairy Sci. 37:202 (1954).
Koch, R.B., B. Stern and C.G. Ferrari, Arch. Biochem. Biophys. 78:165 (1958).
Mitsuda, H., K. Yasumoto and K. Iwami, J. Jpn. Soc. Food Nutr. 19:210 (1966).
Hartman, L., J. Sci. Food Agric. 5:476 (1954).
Siddiqi, A.M., and A.L. Tappel, Chemist. Analyst 44:52 (1955).
Hicks, M., and J.M. Gebicki, Anal. Biochem. 99:249 (1979).
Stamm, J., J. Bull. Soc. Pharm. Estonia 5:181 (1925).
Hamm, D.L., E.G. Hammond, V. Parvanah and H.E. Snyder, J. Am. Oil Chem. Soc. 42:920 (1965).
Eskin, N.A.M., and C. Frankel, J. Am. Oil Chem. Soc. 53:746 (1976).
Takagi, T., Y. Mituno and M. Masumura, Lipids 13:147 (1978).
Asakawa, T., and S. Matsushita, J. Jpn. Soc. Food Nutr. 28:403 (1975).
Asakawa, T., and S. Matsushita, J. Jpn. Soc. Food Nutr. 29:408 (1976).
Asakawa, T., and S. Matsushita, Bull. Res. Inst. Food Sci., Kyoto Univ. 40:12 (1977).
Asakawa, T., and S. Matsushita, J. Am. Oil Chem. Soc. 55:619 (1978).
Terao, J., T. Ogawa and S. Matsushita, Agric. Biol. Chem. 39:397 (1975).
Baldwin, R.R., R.S. Bear and R.E. Rundle, J. Am. Chem. Soc. 66:111 (1944).
Author information
Authors and Affiliations
About this article
Cite this article
Asakawa, T., Matsushita, S. A colorimetric microdetermination of peroxide values utilizing aluminum chloride as the catalyst. Lipids 15, 965–967 (1980). https://doi.org/10.1007/BF02534423