Summary
Limits of detection and quantification (LOD andLOQ) are two fundamental elements of method validation. Although strict statistical definitions exist, a variety of procedures based on different means of estimating the standard deviation of the blank can be used to evaluate these limits. An experiment set up to investigate their compatibility for an LC-UV method has proved they are not equivalent. We therefore recommend an alternative and absolute methodology:LOQ is obtained from the targetRSD chosen for the assay andLOD is taken as three tenths of theLOQ. To demonstrate the method is not restricted to LC-UV it has been applied to LC-MS and GC-FID.
Article PDF
Avoid common mistakes on your manuscript.
References
Huber, L.LC-GC Int. 1998,11, 96–105.
Green, J.M.Anal. Chem. 1996,68, 305A-309A.
Jenke, D.R.J. Liq. Chromatogr. Related Technol. 1996,19, 719–736.
Jenke, D.R.J. Liq. Chromatogr. Related Technol. 1996,19, 737–757.
Feinberg, M.La validation des méthodes d'analyse, Masson, Paris,1996.
Hartmann, C.; Smeyers-Verbeke, J.; Massart, D.L.; McDowall, R.D.J. Pharm. Biomed. Anal. 1998,17, 193–218.
Thompson, M.; Ellison, S.L.R.; Wood, R.Pure Appl. Chem. 2002,74, 835–855.
Massart, D.L.; Vandeginste, B.G.M.; Buydens, L.M.C.; De Jong, S.; Lewi, P.J.; Smeyers-Verbeke, J. InHandbook of Chemometrics and Qualimetrics, Part A, Elsevier, Amsterdam,1997, pp. 422–435.
Currie, L.A.Pure Appl. Chem. 1995,67, 1699–1723.
ICH4.Validation of Analytical Procedures: Methodology, Q2B, ICH Steering Committee London,1996.
EurachemAccreditation for Chemical Laboratories, Eurachem Secretariat, Teddington, UK,1993.
Jardy, A.; Vial, J.; Ménier, I.Analusis 1997,25, 106–111.
Vial, J.; Ménier, I.; Jardy, A.; Anger, P.; Brun, A.; Burbaud, L.J. Chromatogr. B 1998,708, 131–143.
Vial, J.; Jardy, A.; Anger, P.; Brun, A.; Menet, J.M.J. Chromatogr. A 1998,815, 173–182.
Vial, J.; Jardy, A.Chromatographia 2001,53, S141-S148.
Vial, J.; Hennion, M.C.; Fernandez-Alba, A.; Aguera, A.J. Chromatogr. A 2001,937, 21–29.
Vial, J.; Jardy, A.Anal. Chem. 1999,71, 2672–2677.
Geiß, S.; Einax, J.W.Fresenius J. Anal. Chem. 2001,370, 673–678.
Rosset, R.; Caude, M.; Jardy, A. In:Chromatographies en phases liquide et supercritique, Masson, Paris,1991, pp. 135–137.
Boyer, K.W.; Horwitz, W.; Albert, R.Anal. Chem. 1985,57, 454–459.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vial, J., Le Mapihan, K. & Jardy, A. What is the best means of estimating the detection and quantification limits of a chromatographic method?. Chromatographia 57 (Suppl 1), S303–S306 (2003). https://doi.org/10.1007/BF02492120
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02492120