Abstract
A new instrument for the monitoring of eye fixation and pupil size during the visual field examination is described. Particular attention has been given to design an instrument adapted to clinical measurements, requiring minimum subject training. co-operation, discomfort and set up time. Relatively free head movements are permitted by the evaluation of eye orientation from the displacement of the corneal reflection with respect to the centre of the pupil. Considerable thought has also been given to the minimising of costs to permit the introduction of the instrument in the ophthalmic clinic.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Charlier, J. R. (1979) Examen automatique du champ visuel. Etude et réalisation du dispositif de stimulation. Thèse de 3ème cycle. Université de Lille II.
Charlier, J. R. andHache, J. C. (1980) L'examen automatique du champ visuel Problèmes et solutions.Innovation et Technologie en Biologie et Médecine,1, 101–104.
Charlier, J. R. (1980) A new instrument for automatic subjective and objective perimetry.Medical Progress through Technology,7, 125–129.
Cornsweet, T. N. andCrane, H. D. (1973) Accurate twodimensional eye tracker using first and fourth Purkinje images.J. Op. Soc. Amer.,63, 921–930.
Ditchburn, R. W. andGinsborg, B. L. (1953) Involuntary eye movements during fixation.J. Physiol. 119, 1–9.
Dubois, P. (1974) Etude et réalisation d'un dispositif de périmétrie automatique. Thèse de 3ème cycle. Université de Lille I.
Hache, J. C., Dubois, P. andLeflon, G. (1976) Recherche sur la périmetrie automatique.Lille Medical,21, 852–856.
Hache, J. C., Francois, P. andCharlier, J. (1980) La scotométrie en neuro-ophthalmologie: intérêt d'un instrument automatique de mesure du champ visuel. InBulletins et Mémoires de la Société française d'ophthalmologie, Masson et Cie, Paris, 220–223.
Hart, W. M. (1979) Computer applications to visual fields.Computers in ophthalmology, IEEE Computer Society, 157–160.
Keltner, J. L., Johnson, C. A. andBalestrry, F. G. (1979) Suprathreshold static perimetry: initial clinical trials with the Fieldmaster automated perimeter.Archives of Opthalmology,77, 260–272.
Merchant, J. andMorrissette, R. (1974) Remote measurement of eye direction allowing subject motion over one cubic foot of space.IEEE Trans. BME-21, 309–317.
Legrand, Y. (1964)Optique Physiologique, Tome II, Editions de la Revue d'Optique, Paris.
Portney, G. L. andKrohn, M. A. (1978) Automatic perimetry: background instruments and methods.Survey of Ophthalmology,22, 271–278.
Young, L. R. andSheena, D. (1975) Survey of eye movements recording methodsBehaviour Research Methods Instrumentation,7, 397–429.