Abstract
Two new simple models for the arterial tree input impedance are presented. The first is a 4-element windkessel model, obtained by paralleling the characteristic resistance of the 3-element windkessel model (Westerhof, 1968) with an inductance. The second is a tube model with a complex load, which is characterised by four parameters also. The parameters of these models are estimated from aortic root pressure and flow, which are either simulated by a complex numerical model of the peripheral arterial tree or measured in dogs.
The parameter estimation is carried out using an automatic procedure based on the Powell optimisation algorithm. The importance of the evaluation of the achievable accuracy in the estimation of parameters and its relationship to model identifiability is emphasised.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Avanzolini, G., Belardinelli, E., Capitani, G. andPassigato, R. (1971) Steady-state numerical model of the human systemic arterial tree. IFAC Symposium on Automatic Control and Computers in the Medical Field, Bruxelles.
Avanzolini, G., Belardinelli, E. andGnudi, G. (1977) A new method for measuring the arterial tree input impedance and the instantaneous cardiac flow. 1st Mediterranean Conference on Medical and Biological. Engineering, Sorrento, 12–17 September.
Avanzolini, G. andGnudi, G. (1978) Indirect measurement of aortic arch physical and geometrical parameters: preliminary results. BIOSIGMA 78, International Conference on Signals and Images in Medicine and Biology, Paris, 24–28 April.
Bellman, R. andAström, K. J. (1970) On structural identifiability.Mathematical Biosciences,7, 329–339.
Bourne, P. R. andKitney, R. I. (1978) Matching techniques for clinical models of the circulation.Med. & Biol. Eng. & Comput.,16, 689–696.
Burattini, R. (1981) An arterial tree input impedance model: analysis in the frequency domain.Biomechanics,10, 20–29. n.10.
Burattini, R. andGnudi, G. (1980) Computer identification of models for the arterial tree input impedance. BIOMED 80, 2nd Mediterranean Conference on Medical and Biological Engineering, Marseille, 15–19 September, 201–203.
Cooley, J. W. andTukey, J. W. (1965) An algorithm for the machine calculation of complex Fourier series.Mathematics of Computations,19, 297–301.
Damenstein, A., Stout, T. L., Wessel, H. U., Paul, M. H. (1976) Electronic compensator for pressure waveform distortion by fluid-filled catheters.Med. & Biol. Eng.,14, 186–191.
Deswysen, B., Charlier, A. A. andGevers, M. (1980) Quantitative evaluation of the systemic arterial bed by parameter estimation of a simple model.Med. & Biol. Eng. & Comput.,18, 153–166.
Dick, D. E., Kendrick, J. E., Matson, G. L. andRideout, V. C. (1968) Measurement of nonlinearity in the arterial system of the dog by a new method.Circ. Res. 22, 101–112.
Eykhoff, P. (1974)System identification, parameter and state estimation. John Wiley, London, 410–415.
Gabe, I. T., Gault, J. H., Ross, J., Mason, D. T. andMills, C. J. (1969) Measurement of instantaneous blood flow velocity and pressure in conscious man with a catheter-tip velocity probe.Circ., XL,5, 603–614.
Iannone, C. (1978) Impedenza arteriosa. Graduate thesis, Faculty of Engineering, University of Bologna.
Landes, G. (1943) Einige untersuchungen an elektrischen analogieschaltungen zum Kreitslaufsystems.Z. Biol.,101, 418–429.
Laxminarayan, S., Sipkema, P. andWesterhof, N. (1978) Characterization of the arterial system in the time domain.IEEE Trans.,BME-25, 177–184.
Ling, S. C. andAtabek, H. B. (1972) A nonlinear analysis of pulsatile flow in arteries.J. Fluid Mech.,55, 493–511.
Ling, S. C., Atabek, H. B., Letzing, W. G. andPatel, D. J. (1973) Nonlinear analysis of aortic flow in living dogs.Circ. Res.,33, 198–212.
Nichols, W. W., Conti, C. R., Walker, W. E. andMilnor, W. R. (1977) Input impedance of the systemic circulation in manCirc. Res.,40, 451–458.
Powell, M. J. D. (1964) An efficient method for finding the minimum of a function of several variables without calculating derivatives.Computer J.,7, 155–162.
Sims, J. B. (1972) Estimation of arterial system parameters from dynamic records.Computers & Biomed. Res.,5, 131–147.
Westerhof, N. (1968) Analog studies of human systemic arterial haemodynamics. PhD thesis, University of Pennsylvania, Philadelphia.
Westerhof, N., Bosman, F., de Vries, C. J. andNoordergraaf, A. (1969) Analog studies of the human systemic arterial tree.J. Biomechanics,2, 121–143.
Westerhof, N., Elzinga, G. andVan den Bos, G. C. (1973) Influence of central and peripheral changes on the hydraulic input impedance of the systemic arterial tree.Med. & Biol. Eng., 710–723.
Womersley, J. R. (1957) An elastic tube theory of pulse transmission and oscillatory flow in mammalian arteries. WADC Technical Report TR 56-614.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Burattini, R., Gnudi, G. Computer identification of models for the arterial tree input impedance: Comparison between two new simple models and first experimental results. Med. Biol. Eng. Comput. 20, 134–144 (1982). https://doi.org/10.1007/BF02441348
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02441348