Abstract
The absolute quantified measurement of haemoglobin skin blood saturation from collected reflectance spectra of the skin is complicated by the fact that the blood content of tissues can vary both in the spatial distribution and in the amount. These measurements require an understanding of which vascular bed is primarily responsible for the detected signal. Knowing the spatial detector depth sensitivity makes it possible to find the best range of different probe geometries for the measurements of signal from the required zones and group of vessels inside the skin. To facilitate this, a Monte Carlo simulation has been developed to estimate the sampling volume offered by fibre-optic probes with a small source-detector spacing (in the current report 250 μm, 400 μm and 800 μm). The optical properties of the modelled medium are taken to be the optical properties of the Caucasian type of skin tissue in the visible range of the spectrum. It is shown that, for a small source-detector separation (800 μm and smaller), rough boundaries between layers of different refractive index can play a significant role in skin optics. Wavy layer interfaces produce a deeper and more homogeneous distribution of photons within the skin and tend to suppress the direct channelling of photons from source to detector. The model predicts that a probe spacing of 250 μm samples primarily epidermal layers and papillary dermis, whereas spacings of 400–800 μm sample upper blood net dermis and dermis.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Anderson, R. R., andParrish, J. A. (1982): ‘Optical properties of human skin’ inRegan, J. D., andParish, J. A. (Eds): ‘The science of photomedicine’ (Pergamon Press, New York), pp. 147–194
Arridge, S. (1995): ‘Photon-measurement density functions. Part I: Analytical forms’,Appl. Opt. 34, pp. 7395–7409
Born, M., andWolf, E. (1986): ‘Principles of optics: electromagnetic theory of propagation, interference and diffraction of light, 6th edn’ (Pergamon Press)
Cashwell, E. D., andEverett, C. J. (1959): ‘A practical manual on the Monte Carlo method for random walk problems’ (Pergamon Press, London)
Chance, B. (1954): ‘Spectrophotometry of intracellular respiratory pigments’,Science,120, pp. 767–775
Cheong, W. F., Prahl, S. A., andWelch, A. J., (1990): A review of the optical properties of biological tissues’,IEEE J. Quantum Electron.,26, pp. 2166–2185
Corcuff, P., Bertrand, C., andLeveque, J. L. (1993): ‘Morphometry of human epidermisin vivo by real-time confocal microscopy’,Arch. Dermatol. Res.,285, pp. 475–481
De Mul, F. F., Koelink, M. H., Kok, M. L., Harmsma, P. J., Greve, J., Graaff, R., andAarnoudse, J. G. (1995): ‘Laser Doppler velocimetry and Monte Carlo simulation on models for blood perfusion in tissue’,Appl. Opt.,34, pp. 6595–6611
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. M., andSterenborg, H. J. C. M. (1999): ‘The determination ofin vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy’,Phys. Med. Biol. 44, pp. 967–981
Duck, F. A. (1990): ‘Physical properties of tissue’ (Academic Press, San Diego), pp. 43–71
Feather, J. W., Dawson, J. B., Barker, D. J., andCotterill, J. A. (1981): ‘A theoretical and experimental study of optical properties ofin vivo skin’ inMarks, R., andPayne, P. A. (Eds): ‘Bioengineering and the skin’ (MTP, Lancaster), pp. 275–281
Hanna, G. B., Newton, D. J., Harrison, D. K., Belch, J. J. F., andMcCollum, P. T. (1995): ‘Use of lightguide spectrophotometry to quantify skin oxygenation in variable model of venous hypertension’,Br. J. Surg.,82, pp. 1352–1356
Hiraoka, M., Fibrank, M., Essenpreis, M., Cope, M., Arridge, S. R., Van Der Zee, P., andDelpy, D. T. (1993): ‘A Monte Carlo investigation of optical pathlength in homogeneous tissue and its application to near-infrared spectroscopy’,Phys. Med. Biol.,38, pp. 1859–1876
Holbrook, K. A. (1991): ‘Structure and functions of the developing human skin’in Goldsmith, L. A. (Ed.): ‘Physiology, biochemistry, and molecular biology of the skin’ (Oxford University Press, Oxford),1, pp. 63–112
Jacques, S. L., andWang, L. (1995): ‘Monte Carlo modeling of light transport in tissues’in Welch, A. J. andvan Gemert, M. J. C. (Eds): ‘Optical-thermal response of laser-irradiated tissues’ (Plenum Press, New York), pp. 73–100
Jakobsson, A., andNilsson, G. E. (1993): ‘Prediction of sampling depth and photon pathlength in laser Doppler flowmetry’,Med. Biol. Eng. Comput.,31, pp. 301–307
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., andWilson, B. C. (1996): ‘Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue’,Appl. Opt.,35, pp. 2304–2314
Maibach, H. T., andLowe, N. L. (1987): ‘Models in dermatology’ (Karger, New York)
Meier, R. R., Lee, J.-S., andAnderson, D. E. (1978): ‘Atmospheric scattering of middle uv radiation from an internal source’,Appl. Opt.,17, pp. 3216–3225
Nilsson, H., andNilsson, G. E. (1998). ‘Monte Carlo simulations of the light interaction with blood vessels in human skin in the red wavelength region’,Proc. SPIE,3252, pp. 44–53
Odland, G. F. (1991): ‘Structure of the skin’in Goldsmith, L. A. (Ed.): ‘Physiology, biochemistry, and molecular biology of the skin’ (Oxford University Press, Oxford),1, pp. 3–62
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., andDelpy, D. T. (1997): ‘Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head’,Appl. Opt.,36, pp. 21–31
Prahl, S. A., Keijzer, M., Jacques, S. L., andWelch, A. J. (1989): ‘A Monte Carlo model of light propagation in tissue’,SPIE Inst. Series,IS 5, pp. 102–111
Rajadhyaksha, M., andZavislan, J. M. (1998): ‘Confocal reflectance microscopy of unstained tissuein vivo’,Clin. Exp. Techniques,14, pp. 26–30
Ryan, T. J. (1991): ‘Cutaneous circulation’ inGoldsmith, L. A. (Ed.): ‘Physiology, biochemistry, and molecular biology of the skin’ (Oxford University Press, Oxford),2, pp. 1019–1084
Schmitt, J. M., andKumar, G. (1998): ‘Optical scattering properies of soft tissue: a discrete particle model’,Appl. Opt.,37, pp. 2788–2797
Serup, J., andJemec, G. B. E. (Eds) (1995): ‘Skin surface contour evaluation’ in ‘Non-invasive methods and the skin’ (CRC Press, Inc., Boca Raton), chap. 5, pp. 83–131
Sheuplein, R. J. (1964): ‘A survey of some fundamental aspects of the absorption and reflection of light by tissues’,J. Soc. Cosmet. Chem.,15, pp. 155–156
Simpson, C. R., Kohl, M., Essenpreis, M., andCope, M. (1998): ‘Near-infrared optical properties ofex vivo human skin and subcutaneous tissues measured using the Monte Carlo investion technique’,Phys. Med. Biol.,43, pp. 2465–2478
Sliney, D., andWolbarsht, M. (1980): ‘Optical radiation hazards to the skin’, in ‘Safety with lasers and others optical sources. A comprehensive handbook’ (Plenum Press, New York), pp. 161–185
Stenn, K. S. (1988): ‘The skin’in Weiss, L. (Ed.): ‘Cell and tissue biology’, (Urban & Shwarzenberg, Baltimore), pp. 541–572
Tuchin, V. V., Utz, S. R., andYaroslawvsky, I. V. (1994): ‘Tissue optics, light distribution, and spectroscopy’,Opt. Eng.,33, pp. 3178–3188
Tuchin, V. V. (1998): ‘Lasers and fiber optics in biomedical investigations (in Russian)’ (Saratov State University Press, Saratov)
Van Der Zee, P. (1992): ‘Measurement and modeling of the optical properties of human tissue in the near infrared’. PhD dissertation, University of London, p. 313
Wang, L., Jacques, S. L., andZheng, L. (1995): ‘MCML—Monte Carlo modeling of light transport in multi-layered tissues’,Comput. Methods Programs Biomed.,47, pp. 131–146
Yoo, K. M., Liu, F., andAlfano, R. R. (1990): ‘When does the diffusion approximation fail to describe photon transport in random media?’,Phys. Rev. Lett.,64, pp. 2647–2650
Young, A. R. (1997): ‘Chromophores in human skin’,Phys. Med. Biol.,42, pp. 789–802
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Meglinsky, I.V., Matcher, S.J. Modelling the sampling volume for skin blood oxygenation measurements. Med. Biol. Eng. Comput. 39, 44–50 (2001). https://doi.org/10.1007/BF02345265
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02345265