Summary
A new computational procedure for the simultaneous calibration of separation and axial dispersion by using SEC coupled with a LALLS detector is presented. Its performance is tested by SEC/LALLS experiments with commercially available samples of broad and narrow polystyrene standards. The peakbroadening parameters were calculated by a novel method which utilizes the different effects of axial dispersion on polymers with narrow and broad molecular weight distribution. The dispersion function was assumed to be gaussian. The variation of the dispersion parameter with molecular weight is in good agreement with reports in the literature. Experimental chromatograms have been corrected for the axial dispersion effect.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
J. V. Dawkins, in ‘Steric Exclusion Liquid Chromatography of Polymers’, Chromatographic Science Series, Vol. 25, J. Janca, Ed., Dekker, New York, 1984, p. 53.
A. E. Hamielec, in ‘Steric Exclusion Liquid Chromatography of Polymers’, Chromatographic Science Series, Vol. 25, J. Janca, Ed., Dekker, New York, 1984, p. 117.
‘Modern Liquid Chromatography of Macromolecules’, Journal of Chromatography Library — vol. 25,B. G. Belenkii, L. Z. Vilenchik, Elsevier, New York, 1983, p. 117.
L. H. Tung, J. C. Moore, G. W. Knight, J. Appl. Polym. Sci.10, 1261 (1966).
D. Alba, G. R. Meira, J. Liq. Chromatog.,9 (6), 1141 (1986).
K. C. Berger, Makromol. Chem.176, 399 (1975).
Y. Chen, M. Ye, X. Li, L. Shi, J. Liq. Chromatog.,9 (6), 1163 (1986).
Z. D. He, X. Ch. Zhang, R. S. Cheng, J. Liq. Chromatogr.,5(7), 1209 (1982).
T. O. Nguyen, H.-H. Kausch, One Day Advanced Symposium on Size Exclusion Chromatography, Lausanne, 1987.
M. Netopilik, Polymer Bulletin7, 575 (1982).
K. Lederer, G. Imrich-Schwarz, M. Dunky, J. Appl. Polym. Sci.,32 4751 (1986).
G. Glöckner, J. Liq. Chromatog.7 (9), 1769 (1984).
L. H. Tung, J. Appl. Polym. Sci.13, 775 (1969).
K. C. Berger, Makromol. Chem.179, 719 (1978).
W. W. Yau, H. J. Stoklosa, D. D. Bly, J. Appl. Polym. Sci.21, 1911 (1977).
P. Fromment, A. Revillon, J. Liq. Chromatog.,10 (7), 1383 (1987).
R. Hooke, T. A. Jeeves, J. of the Assn. for Computing Machinery8, 212 (1961).
J. A. Nelder, R. Mead, The Computer Journal,7, 308 (1965).
T. Ishige, S.-I. Lee, A. E. Hamielec, J. Appl. Polym. Sci.,15, 1607 (1971).
G. Rois, Diplomarbeit Sept. 1987, Montanuniversität Leoben.
R. Brüssau, GIT Fachz. Lab. 5/87, 388.
R. Brüssau in ‘Liquid Chromatography of Polymers and Related Materials II’,J. Cazes andX. Delaware, Eds., Marcel Dekker, New York, 1980, p. 73.
R. Cheng, S. Bo in ‘Size Exclusion Chromatography, Methodology and Characterization of Polymers and Related Materials’, ACS Symposium Series 245, T. Provder, Ed., 1984, p. 125.
G. Eggink, J. A. P. P. van Dijk, J. A. M. Smit, Polymer Bulletin17, 531 (1987).
A. C. Ouano, J. Chromatogr.,118, 303–312 (1976).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Billiani, J., Rois, G. & Lederer, K. A new procedure for simultaneous calibration of separation and axial dispersion in SEC. Chromatographia 26, 372–376 (1988). https://doi.org/10.1007/BF02268184
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF02268184