Summary
We report a new apparatus to determine the quasistatic, three-dimensional, load-displacement characteristics of spines including muscle forces. The loading frame can be adapted to mono- and polysegmental specimens from the lumbar or cervical spine as well as to entire spines. Three force and three moment components can be applied in either direction individually or in combination with no constraint on the resulting motion; the loads can be applied at user-chosen rates of application and release with continuous recording of displacements, so as to study either creep or relaxation. The loads and displacement-measuring devices are computer-controlled. Thus, this testing device provides a tool for many kinds of stability tests and for basic research of spine biomechanics. A first experiment shows that the application of muscle forces significantly affects the load-deformation characteristics and intradiscal pressure.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Abumi K, Panjabi MM, Duranceau J (1989) Biomechanical evaluation of spinal fixation devices. 111. Stability provided by six spinal fixation devices and interbody bone graft. Spine 14: 1249–1255
Ashman RB, Galpin RD, Corin JD, Johnston CE (1989) Biomechanical analysis of pedicle screw instrumentation systems in a corpectomy model. Spine 14:1398–1405
Brown T, Hansen RJ, Yorra AJ (1957) Some mechanical tests on the lumbosacral spine with particular reference to the intervertebral discs. J Bone Joint Surg [Am] 39:1135–1164
Eggli S, Schläpfer F, Angst M, Witschger P, Aebi M (1992) Biomechanical testing of three newly developed transpedicular multisegmental fixation systems. Eur Spin J 1: 109–116
El-Bohy AA, Yang K-H, King AI (1989) Experimental verification of facet load transmission by direct measurements of facet lamina contact pressure. J Biomech 22:931–941
Goel VK, Goyal S, Clark C, Nishiyama K (1985) Kinematics of the whole lumbar spine. Spine 10:543–554
Goel VK, Nye TA, Clark CR, Nishiyma K, Weinstein JN (1987) A technique to evaluate an internal spine device by use of the Selspot system — an application to the Luque closed loop. Spine 12:150
Markolf KL (1972) Deformation of the thoracolumbar intervertebral joints in response to external loads. J Bone Joint Surgery [Am] 54:511–533
Mickley K, Nolte LP (1989) Experimentelle Bestimmung biomechanischer Modellparameter ein- und mehrsegmenteller Lendenwirbelabschnitte. VDI Berichte 731:443–452
Mickley K, Nolte LP, Stumpf H, Lange H, Beerens C, Krämer J (1990) Eine Versuchsanlage für biomechanische Studien an menschlichen Wirbelsdulenprdparaten. Messtechnische Briefe 26:10–16
Nachemson A (1963) The influence of spinal movements on the lumbar intradiscal pressure and on the tensile stresses in the annulus fibrosus. Acta Orthop Scand 33:183–207
Nachemson AL (1981) Disc pressure measurements. Spine 6: 93–97
Panjabi MM, Brand RA, White AA (1976) Mechanical properties of the human thoracic spine. J Bone Joint Surg [Am] 58: 642–652
Panjabi MM (1977) Experimental determination of spinal motion segment behavior. Orthop Clin North Am 8:169–181
Panjabi MM (1988) Biomechanical evaluation of spinal fixation devices. I. A conceptual framework. Spine 13:1129–1134
Panjabi MM, Brand RM, White AA (1976) Three-dimensional flexibility and stiffness properties of the human thoracic spine. J Biomech 9:185–192
Panjabi MM, Krag MH, White AA, Southwick WO (1977) Effects of preload on load displacement curves of the lumbar spine. Orthop Clin North Am 8:181–193
Panjabi MM, Abumi K, Druanceau J, Crisco JJ (1988) Biomechanical evaluation of spinal fixation devices. 11. Stability provided by eight internal fixation devices. Spine 13:1135–1140
Panjabi MM, Abumi K, Duranceau J, Oxland T (1989) Spinal stability and intersegmental muscle forces — a biomechanical model. Spine 14:194–200
Panjabi MM, Yamamoto I, Oxland TR, Crisco JJ, Freedman D (1991) Biomechanical stability of five pedicle screw fixation systems in a human lumbar spine instability model. Clin Biomech 6:197–205
Sutterlin CE, McAffee PC, Warden KE, Rey RM, Farey ID (1988) A biomechanical evaluation of cervical spinal stabilization method in a bovine model — static and cyclical loading. Spine 13:795–802
Ulrich C, Woersdoerfer O, Klaff R, Claes L, Wilke H-J (1991) Biomechanics of fixation systems to the cervical spine. Spine 16:4–9
Wen N, Dantin JJ, Lavaste F (1992) Static biomechanical properties of normal and degenerated human cervical spine in vitro. VIII Meeting of the European Society of Biomechanics, Rome, June 21–24, 198
White AA, Panjabi MM (1980) Clinical biomechanics of the spine, 2nd edn. Lippincott, Philadelphia
Wilke H-J, Fischer K, Kugler A, Magerl F, Claes L, Wörsdörfer O (1992) In vitro intestigations of internal fixation systems of the upper cervical spine. I. Stability of the direct anterior screw fixation of'the odontoid. Eur Spine J 1: 185–190
Wilke H-J, Fischer K, Kugler A, Magerl F, Claes L, Wörsdörfer O (1992) In vitro intestigations of internal fixation systems of the upper cervical spine. II. Stability of posterior atlanto-axial fixation techniques. Fur Spine J 1: 191–199
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wilke, H.J., Claes, L., Schmitt, H. et al. A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3, 91–97 (1994). https://doi.org/10.1007/BF02221446
Issue Date:
DOI: https://doi.org/10.1007/BF02221446