Abstract
Analytical bias due to neutron scattering and absorption in cold neutron prompt gamma-ray activation analysis (CNPGAA) is largely eliminated for homogeneous samples when element ratios are measured. Application of sensitivity ratios (measured relative to titanium) to the multielement analysis of the Allende meteorite increases both the speed and accuracy of the measurement. Greater measurement accuracy is achieved for some samples when ratios of element concentrations are reported. Problems are encountered when applying the ratio method to measurement of elements which deviate from 1/v behavior, and when gamma-ray attenuation or sample heterogeneity are significant.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
J. R. D. COPLEY, C. A. STONE, Nucl. Instrum. Methods Phys. Res., A281 (1989) 593.
E. A. MACKEY, G. E. GORDON, R. M. LINDSTROM, D. L. ANDERSON, Anal. Chem., 64 (1992) 2366.
E. A. MACKEY, J. R. D. COPLEY, J. Radioanal. Nucl. Chem., 167 (1993) 127.
R. L. PAUL, E. A. MACKEY, J. Radioanal. Nucl. Chem., 181 (1994) 321.
E. A. MACKEY, Biological Trace Element Research, 43/45 (1994) 103.
R. F. FLEMING, Int. J. Appl. Radiation Isotopes, 33 (1982) 1263.
Y. S. KHRBISH, N. M. SPYROU, J. Radioanal. Nucl. Chem., 151 (1991) 55.
R. M. LINDSTROM, R. F. FLEMING, R. L. PAUL, E. A. MACKEY, Proc. Intem.k 0 Users Workshop, Gent, 1992, p. 121.
M. ROSSBACH, F. DE CORTE, Proc. Intern.k 0 Users Workshop, Gent, 1992, p. 125.
R. W. STOUGHTON, J. HALPERIN, Nucl. Sci. Eng., 6 (1959) 100.
R. M. LINDSTROM, R. ZEISLER, D. H. VINCENT, R. R. GREENBERG, C. A. STONE, E. A. MACKEY, D. L. ANDERSON, D. D. CLARK, J. Radioanal. Nucl. Chem., 63 (1993) 121.
R. L. PAUL, R. M. LINDSTROM, D. H. VINCENT, J. Radioanal. Nucl. Chem., 180 (1994) 263.
J. H. SCOON, Bulk chemical analysis of the Allende Meteorite Reference Sample, in: The Allende Meteorite Reference Sample, E. JAROSEWICH, R. S. CLARKE, JR., J. N. BARROWS (Eds), Smithsonian Contrib. Earth Sci., 27 (1987) 39.
J. P. WILLIS, X-ray fluorescence spectrometric analysis of the Allende Meteorite Reference Sample, in: The Allende Meteorite Reference Sample, E. JAROSEWICH, R. S. CLARKE, JR., J. N. BARROWS (Eds) Smithsonian Contrib. Earth Sci., 27 (1987) 46.
Recommended values given by JAROSEWICH, in: The Allende Meteorite Reference Sample, E. JAROSEWICH, R. S. CLARKE, JR., J. N. BARROWS (Eds), Smithsonian Contrib. Earth Sci., 27 (1987) 1.
R. L. PAUL, R. M. LINDSTROM, Review of Progress in Quantitative Nondestructive Evaluation, Vol. 13, D. O. THOMPSON and D. E. CHIMENTI (Eds), Plenum Press, New York, 1994.
R. L. PAUL, NIST Report of Analysis No. 5567, September 8, 1994.
R. M. LINDSTROM, R. L. PAUL, D. H. VINCENT, R. R. GREENBERG, J. Radioanal. Nucl. Chem., 180 (1994) 271.
D. A. NEUMANN, J. R. D. COPLEY, D. REZNIK, W. A. KAMITAKAHARA, J. J. RUSH, R. L. PAUL, R. M. LINDSTROM, J. Phys. Chem. Solids, 54 (1993) 1699.
F. A. KRUG, T. SCHOBER, R. L. PAUL, T. SPRINGER, Solid State Ionics, in press.
K. DEBERTIN, R. G. HELMER, Gamma- and X-Ray Spectrometry with Semiconductor Detectors, Elsevier Science Publishers B.V., Amsterdam, The Netherlands, 1988.
H. CHEN, V. A. SHAROV, D. F. R. MILDNER, R. G. DOWNING, R. L. PAUL, R. M. LINDSTROM, C. J. ZEISSLER, Q.-F. XIAO, Nucl. Instrum. Meth. B, 95 (1995) 107.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Paul, R.L. The use of element ratios to eliminate analytical bias in cold neutron prompt gamma-ray activation analysis. Journal of Radioanalytical and Nuclear Chemistry, Articles 191, 245–256 (1995). https://doi.org/10.1007/BF02038220
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02038220