The author argues that a simple analog needle display can provide the anesthesiologist with the essential information he or she needs when monitoring carbon dioxide in the patient airway. He argues that essentially the most important information is virtually a binary, or all or none, phenomenon; in other words, carbon dioxide is either continuously present in the breathing circuit or is absent. Thus, circuit disconnects and undesirable endotracheal tube locations are readily identified. He relates the analog display of information to that of an automobile speedometer or the hands of a standard wrist watch. The author also compares analog meters with those used by pilots in aviation. He concludes with the argument that the carbon dioxide analyzer provides necessary information without the need to resort to expensive microprocessed displays that would include the waveform and trending, but would substantially increase the cost of the instrument.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Cozanitis DA, Paloheimo MP. Operating room pollution of “capnographs.” Anesth Analg 1986;65:990–991. Letter
Waters DJ, Mapleson WW. Rebreathing during controlled respiration with various semi-closed anesthetic systems. Br J Anaesth 1961;33:374–381
Spoerel WE. Rebreathing and end-tidal CO2 during spontaneous breathing with the Bain circuit. Can Anaesth Soc J 1983;30:145–154
Linko K, Paloheimo M, Tammisto T. Capnography for detection of accidental oesophageal intubation. Acta Anaesthesiol Scand 1983;27:199–202
Murray IP, Modell JH. Early detection of endotracheal tube accidents by monitoring of carbon dioxide concentration in respiratory gas. Anesthesiology 1983;59:334–346
Takki S, Aromaa U, Kauste A. The validity and usefulness of the end-tidal pCO2 during anesthesia. Ann Clin Res 1972;4:278–284
Poppius H, Korhonen O, Viljanen AA, Kreus KE. Arterial to end-tidal CO2 difference in respiratory disease. Eur J Respir Dis 1975;56:254–262
Whitesell R, Asiddao C, Gollman D, Jablowski J. Relationship between arterial and peak expired carbon dioxide pressure during anesthesia and factors influencing the difference. Anesth Analg 1981;60:508–512
Raemer DB, Francis D, Philip JH, Gabel RA. Variation inPCO 2 between arterial blood and peak expired gas during anesthesia. Anesth Analg 1983;62:1065–1069
Paloheimo M, Valli M, Ahjopalo H. A guide to CO2 monitoring. Helsinki: DATEX Instrumentarium Oy, 1983
Cote CJ, Liu LMP, Szyfelbein SK, et al. Intraoperative events diagnosed by expired carbon dioxide monitoring in children. Can Anaesth Soc J 1986;33:315–320
Kalenda Z. Capnography during anesthesia and intensive care. Acta Anesthesiol Belg 1978;29:201–208
Smalhout B, Kalenda Z. An atlas of capnography. Zeist, The Netherlands: Kerckebosch, 1980:222 pp
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Paloheimo, M.P.J. A carbon dioxide monitor that does not show the waveform has value. J Clin Monitor Comput 4, 210–212 (1988). https://doi.org/10.1007/BF01621818
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01621818