Abstract
The microbiological quality of filtered water in a commercial water filter system (Brita) was tested in households and in two laboratories. In 24 of 34 filters used in households, bacterial counts increased in the filtered water up to 6,000 cfu/ml. In 4 of 6 filters tested in the laboratory, bacterial counts in the fresh filtrate were higher than in tap water after approximately one week of use both at room temperature and at 4°C, suggesting growth or biofilm formation in the filter material. In some cases colony counts in the filtered water were 10,000 times those in tap water. The filter material of 5 of 13 new commercial filters was contaminated with bacteria or moulds. National or international regulatory agencies should ensure that water filters marketed for domestic use do not allow deterioration in the microbiological quality of drinking water.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Payment P: Bacterial colonization of domestic reverseosmosis water filtration units. Canadian Journal of Microbiology 1989, 35: 1065–1067.
Geldreich EE, Taylor E, Blannon JC, Reasoner D: Bacterial colonization of point-of-use water treatment devices. Journal of American Water Works Association 1985, 77: 72–80.
Resoner DJ, Blannon JC, Geldreich EE: Microbiology of granular activated carbon home treatment devices. In: Janauer I (ed): Proceedings of the Third Conference on Progress in Chemical Disinfection. State University of New York, Binghampton, NY, 1986, p. 223–242.
Environmental Protection Agency: National primary drinking water regulations; filtration and disinfection; turbidity, and heterotrophic bacteria; proposed rule. Federal Register 1987, 52: p. 42, 178–42, 222.
Payment P, Richardson L, Siemiatycki J, Dewar R, Edwardes M, Franco E: A randomized trial to evaluate the risk of gastrointestinal disease due to consumption of drinking water meeting current microbiological standards. American Journal of Public Health 1991, 81: 703–708.
Van der Kooij D: Nutritional requirements of aeromonads and their multiplication in drinking water. Experientia 1991, 47: 444–446.
Camper AK, McFeters GA, Characklis WG, Jones WL: Growth kinetics of coliform bacteria under conditions relevant to drinking water distribution systems. Applied and Environmental Microbiology 1991, 57: 2233–2239.
Rogers J, Dowsett AB, Dennis PJ, Lee JV, Keevil CW: Influence of temperature and plumbing material selection on biofilm formation and growth ofLegionella pneumophila in a model potable water system containing complex microbial flora. Applied and Environmental Microbiology 1994, 60: 1585–1592.
Cason JS, Jackson DM, Lowbury EJL, Ricketts CR: Antiseptic and aseptic prophylaxis for burns: use of silver nitrate and of isolators. British Medical Journal 1966, 26: 1288–1294.
Annear DI, Mee BJ, Bailey M: Instability and linkage of silver resistance, lactose fermentation and colony structure inEnterobacter cloacae from burn wounds. Journal of Clinical Pathology 1976, 29: 441–443.
McHugh GL, Moellering RC, Hopkins CC, Schwartz MN:Salmonella typhimurium resistant to silver nitrate, chloramphenicol and ampicillin. Lancet, 1975 i: 235–240.
Sonntag HG: Quality of drinking water after processing in practices and households. Zentralblatt für Bakteriologie und Hygiene 1987, B 187: 324–336.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Daschner, F.D., Rüden, H., Simon, R. et al. Microbiological contamination of drinking water in a commercial household water filter system. Eur. J. Clin. Microbiol. Infect. Dis. 15, 233–237 (1996). https://doi.org/10.1007/BF01591360
Issue Date:
DOI: https://doi.org/10.1007/BF01591360