Summary
A simple, sensitive, reliable and reproducible isocratic HPLC technique for the measurement of OPA/sulphite derivatives of human brain amino acid neurotransmitters is described. This employs a sample preparation that is also compatible with the concurrent determination of monoamines and their metabolites on a separate HPLC system. The method has been applied to the determination of GABA and glutamate in brain tissue taken post-mortem from patients with Huntington's disease and control subjects.
Article PDF
Avoid common mistakes on your manuscript.
References
Allison LA, Mayer GS, Shoup RE (1984) O-phthalaldehyde derivatives of amines for high speed liquid chromatography. Anal Chem 56: 1089–1096
Bidlingmeyer BA, Cohen SA, Tarvin TL (1984) Rapid analysis of amino acids using precolumn derivatisation. J Chromatogr 336: 93–104
Caudill WL, Houck GP, Wightman RM (1982) Determination ofγ-aminobutyric acid by liquid chromatography with electrochemical detection. J Chromatogr 227: 331–339
DeJong C, Hughes GJ, Van Wieringen E, Wilson KJ (1982) Amino acid analyses by high-performance liquid chromatography — an evaluation of the usefulness of precolumn DNS dervatisation. J Chromatogr 241: 345–359
Ellison DW, Beal MF, Martin JB (1987) Amino acid neurotransmitters in postmortem human brain analysed by high performance liquid chromatography with electrochemical detection. J Neurosci Methods 19: 305–315
Freeman ME, Co C, Mote TR, Lane JD, Smith JE (1980) Determination of content and specific activity of amino acids in central nervous system tissue utilizing tritium and Carbon-14 dual labelling. Anal Biochem 106: 191–194
Jacobs WA (1987) O-phthalaldehyde-sulfite derivatization of primary amines for liquid chromatography-electrochemistry. J Chromatogr 392: 435–441
Joseph MH, Davies P (1983) Application to high-performance liquid Chromatographic determination of amino acids in plasma and other biological materials. J Chromatogr 277: 125–136
Kravitz EA, Potter DD (1965) A further study of the distribution of gamma-aminobutyric acid between excitatory and inhibitory axons of the lobster. J Neurochem 12: 323–328
Lindroth P, Mopper K (1979) High performance liquid Chromatographic determination of subpicomole amounts of amino acids by pre-column fluorescence derivatisation with o-phthaldialdehyde. Anal Chem 51: 1667–1674
Marsden CA (1984) Measurement of neurotransmitter release in vivo. Wiley, New York
Perry TL, Berry K, Hansen S, Diamond S, Mok C (1971) Regional distribution of amino acids in human brain obtained at autopsy. J Neurochem 18: 513–519
Perry TL, Hansen S, Kloster M (1973) Huntington's chorea: deficiency of gamma-aminobutyric acid in brain. N Engl J Med 288: 337–342
Reynolds GP, Pearson SJ (1987) Decreased glutamic acid and increased 5-hydroxytryptamine in Huntington's disease brain. Neurosci Lett 78: 223–238
Reynolds GP, Pearson SJ, Heathfield KWG (1990) Dementia in Huntington's disease is associated with neurochemical deficits in the caudate nucleus, not the cerebral cortex. Neurosci Lett 113: 95–100
Reynolds GP, Warner CEJ (1988) Amino acid neurotransmitter deficits in adult Down's syndrome brain tissue. Neurosci Lett 94: 224–227
Rossor M, Iversen LL (1986) Non-cholinergic neurotransmitter abnormalities in Alzheimer's disease. Br Med Bull 42: 70–75
Rubenstein M, Chen-Kiang S, Stein S, Udenfriend S (1979) Characterisation of proteins and peptides by high-performance liquid chromatography and fluorescence monitoring of their tryptic digests. Anal Biochem 95: 117–121
Spackman DH, Stein WH, Moore S (1958) Automatic recording apparatus for use in the chromatography of amino acids. Anal Chem 30: 1190–1205
Spokes EGS (1979) An analysis of factors influencing measurements of dopamine, noradrenaline, glutamate decarboxylase and choline acetylase in human post-mortem tissue. Brain 102: 333–346
Stein S, Boehlen P, Stone J, Dairman W, Udenfriend S (1973) Amino acid analysis with fluorescamine at the picomole level. Arch Biochem Biophys 155: 202–212
Author information
Authors and Affiliations
Additional information
This work was supported by the Wellcome Trust and the Association to Combat Huntington's Chorea. Brain tissue was provided by the Cambridge Brain Bank Laboratory. We thank Dr. M. Joseph for drawing our attention to the potential of this technique.
Rights and permissions
About this article
Cite this article
Pearson, S.J., Czudek, C., Mercer, K. et al. Electrochemical detection of human brain transmitter amino acids by high-performance liquid chromatography of stable O-phthalaldehyde-sulphite derivatives. J. Neural Transmission 86, 151–157 (1991). https://doi.org/10.1007/BF01250576
Received:
Accepted:
Issue Date: