Summary
The relationship between acoustic myography (AMG), electromyography (EMG) and force during submaximal dynamic contractions was examined in the biceps brachii muscles of eight healthy males (aged 17–26 years). Different weights were lifted and lowered at a constant speed, using a wall pulley system, to perform concentric and eccentric contractions, respectively. Integrated AMG (iAMG) and integrated EMG (iEMG) activity both increased linearly with force during concentric (iAMGr=0.94; iEMGr=0.99) and eccentric (iAMGr=0.90; iEMGr=0.94) contractions. The slopes of the concentric regression lines were significantly different from the eccentric slopes (P<0.01) for both iAMG and iEMG with concentric contractions showing greater levels of activity. The results indicated that AMG can be used to detect changes in force during dynamic contractions which has important implications for the use of AMG in rehabilitation. The differences in iAMG activity between concentric and eccentric contractions are discussed in relationship to the origin of the AMG signal.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Barry DT (1987) Acoustic signals from frog skeletal muscles. Biophys J 51:775–783
Barry DT, Cole NM (1988) Fluid mechanics of muscle vibration. Biophys J 53:899–905
Barry DT, Geiringer SR, Ball RD (1985) Acoustic myography: a non invasive monitor of motor fatigue. Muscle Nerve 8:189–194
Barry DT, Leonard JA, Gitter AJ, Ball RD (1986) Acoustic myography as a control signal for an externally powered prosthesis. Arch Phys Med Rehab 67:267–269
Bigland B, Lippold OCJ (1954) The relation between force, velocity and integrated electrical activity in human muscles. J Physiol 123:214–224
Bigland-Ritchie B, Woods JJ (1976) Integrated electromyogram and oxygen uptake during positive and negative work. J Physiol 260:267–277
Bolton CF, Parkes A, Thompson TR, Clark MR, Sterne CJ (1989) Recording sound from human skeletal muscle: technical and physiological aspects. Muscle Nerve 12:126–134
Diemont B, Maranzana Figini M, Orizio C, Perini R, Veicsteinas A (1987a) Testing algorithms for appropriate spectral analysis of muscular sound. Proceedings of the 7th Nordic Meeting on Medical and Biological Engineering, Trondheim, Norway. Institute of Biomedical Engineering, Trondheim, pp 147–214
Diemont B, Maranzana Figini M, Orizio C, Perini R, Veicsteinas A (1987b) Correlated spectral analysis of EMG and muscular sound (SMG) for the study of motor unit firing pattern. Proceedings of the IEEE/EMBS 9th Annual Conference, Boston, USA, vol 1. IEEE Publisher, New York, pp 341–342
Edwards RG, Lippold OCJ (1956) The relation between force and integrated electrical activity in fatigued muscle. J Physiol 132:677–681
Frangioni JV, Kwan-Gett TS, Dobrunz LE, McMahon TA (1987) The mechanism of low frequency sound production in muscle. Biophys J 51:775–783
Komi PV (1973) Relationship between muscle tension, EMG and velocity of contraction under concentric and eccentric work. In: Desmedt J (ed) New developments in electromyography and clinical neurophysiology, vol 1. Karger, Basel, pp 596–606
Komi PV, Kaneko M, Aura O (1987) EMG activity of the leg extensor muscles with special reference to mechanical efficiency in concentric and eccentric exercise. Int J Sports Med 8:[Suppl] 22–29
Maton B, Petitjean M, Cnockaert JC (1990) Phonomyogram and electromyogram relationships with isometric force reinvestigated in man. Eur J Appl Physiol 60:194–201
Moritani T, Muramatsu S, Muro M (1988) Activity of motor units during concentric and eccentric contractions. Am J Phys Med 66:338–350
Orizio C, Perini R, Veicsteinas A (1989a) Changes of muscular sound during sustained isometric contraction up to exhaustion. J Appl Physiol 66:1593–1598
Orizio C, Perini R, Veicsteinas A (1989b) Muscular sound and force relationship during isometric contraction in man. Eur J Appl Physiol 58:528–533
Oster G, Jaffe JS (1980) Low frequency sounds from sustained contraction of human skeletal muscle. Biophys J 30:119–128
Rhatigan BA, Mylrea KC, Lonsdale E, Stern LZ (1986) Investigation of sound produced by healthy and diseased human muscle contraction. IEEE Trans Biomed Eng 33:967–971
Rouse ME, Baxendale RH (1991) A comparison of the frequency content of muscle sounds and electromyogram during voluntary isometric contractions in man. J Physiol 435:80P
Stokes MJ (1991) Acoustic myography reflects force oscillation during stimulated contractions of the human adductor pollicis muscle. J Physiol 435:81P
Stokes MJ, Dalton PA (1990) Muscle sounds reflect voluntary force in the fatigued human quadriceps. Proc Aust Neurosci Soc 1:131
Stokes MJ, Dalton PA (1991) Acoustic myography activity increases linearly up to maximal voluntary isometric force in the human quadriceps muscle. J Neurol Sci 101:163–167
Stokes IAF, Moffroid MS, Rush S, Haugh LD (1988) Comparison of acoustic and electrical signals from erectors spinae muscles. Muscle Nerve 11:331–336
Wee AS, Ashley RA (1989) Vibrations and sound produced during sustained voluntary muscle contraction. Electromyogr Clin Neurophysiol 29:333–337
Woods JJ, Bigland-Ritchie B (1983) Linear and non-linear surface EMG/force relationships in human muscles. Am J Phys Med 62:287–299
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Dalton, P.A., Stokes, M.J. Acoustic myography reflects force changes during dynamic concentric and eccentric contractions of the human biceps brachii muscle. Europ. J. Appl. Physiol. 63, 412–416 (1991). https://doi.org/10.1007/BF00868071