Abstract
To determine if end-tidal carbon dioxide tension (PetCO2) is a clinically reliable indicator of arterial carbon dioxide tension (PaCO2) under conditions of heterogeneous tidal volumes and ventilation-perfusion inequality, we examined the expiratory gases of 25 postcardiotomy patients being weaned from ventilator support with intermittent mandatory ventilation. Using a computerized system that automatically sampled airway flow, pressure, and expired carbon dioxide tension, we were able to distinguish spontaneous ventilatory efforts from mechanical ventilatory efforts. ThePetCO2 values varied widely from breath to breath, and the arterial to end-tidal carbon dioxide tension gradient was appreciably altered during the course of several hours. About two-thirds of the time, thePetCO2 of spontaneous breaths was greater than that of ventilator breaths during the same 70-second sample period. The most accurate indicator of PaCO2 was the maximalPetCO2 value in each sample period, the correlation coefficient being 0.768 (P < 0.001) and the arterial to end-tidal gradient being 4.24 ± 4.42 mm Hg (P < 0.01 compared with all other measures). When all values from an 8-minute period were averaged, stability was significantly improved without sacrificing accuracy. We conclude that monitoring the maximalPetCO2, independent of breathing pattern, provides a clinically useful indicator of PaCO2 in postcardiotomy patients receiving intermittent mandatory ventilation.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Burton GW. The value of CO2 monitoring during anesthesia. Anaesthesia 1966;21:173–183
Hatle L, Rokseth R. The arterial to end-expiratory CO2 tension gradient in acute pulmonary embolism and other cardiopulmonary diseases. Chest 1974;66:353–357
Poppius H. Arterial to end-tidal CO2 differences in respiratory disease. Scand J Respir Dis 1975;56:254–262
Whitesell R, Asiddao C, Gollman D, Jablonsk J. Relationship between arterial and peak expired carbon dioxide pressure during anesthesia and factors influencing the difference. Anesth Analg 1981;60:508–512
Perrin G, Perrot D, Holzapfel L, Robert D. Simultaneous variations of PaCO2 and PACO2 in assisted ventilation. Br J Anaesth 1983;55:525–530
Kinsella SM. Assessment of the Hewlett-Packard HP47210A capnometer. Br J Anaesth 1985;57:919–923
Brimm JE, Bienzo RK, Knight MA, Peters RM. Breathby-breath end-tidal CO2 analysis for patients on IMV. In Prakash O, ed. Computers in critical care and pulmonary medicine. New York: Plenum, 1982:195–200
Nie NH, Hull CH, Jenkins JG, et al. Statistical package for the social sciences (SPSS). 2nd ed. New York: McGraw-Hill, 1975
Snedecor GW, Cochran WG. Statistical methods. 7th ed. Ames: Iowa State University, 1980:185–188
Feeley TW, Hedley-Whyte J. Weaning from controlled ventilation and supplemental oxygen. N Engl J Med 1975;292:903–906
Burton GW. Measurement of inspired and expired O2 and CO2. Br J Anaesth 1969;41:723–730
Gothard JW, Busst CM, Brantwaite MA, et al. Applications of respiratory mass spectrometry to intensive care. Anaesthesia 1980;35:890–895
Riker JB, Haberman B. Expired gas monitoring by mass spectrometry in a respiratory ICU. Crit Care Med 1976;4:223–229
Potter WA. Mass spectrometry for innovative techniques of respiratory care, ventilator weaning, and differential ventilation in an ICU. Crit Care Med 1976;4:235–238
Capan LM, Ramanathan S, Sinha K, Turndorf H. Arterial to end-tidal C02 gradients during spontaneous breathing, intermittent positive-pressure ventilation, and jet ventilation. Crit Care Med 1985;13:810–813
Collier CR, Affekdt JE, Farr AF. Continuous rapid infrared C02 analysis. J Clin Lab Med 1976;45:526–539
Evans JM, Hogg MJ, Rosen M. Correlation of alveolar PCO2 estimated by infrared analysis and arterial PCO2 in the human neonate and the rabbit. Br J Anaesth 1977;49:761–764
Briscoe WA, Firster RE, Comroe JH. Alveolar ventilation at very low tidal volumes. J Appl Physiol 1954;7:27–30
Dubois AB, Britt AG, Fenn WO. Alveolar C02 during the respiratory cycle. J Appl Physiol 1952;4:535–548
Jones NL, Robertson DG, Kane JW. Difference between end-tidal and arterial PCO2 during exercise. J Appl Physiol 1979;47:954–960
Smalhout B, Kalenda Z. An atlas of capnography. Vol. 1. 2nd ed. The Netherlands: Kerkebosch-Zeist, 1981
Lewis G, Ponte J, Purves MJ. Fluctuation of PaCO2 with the same period as respiration in the cat. J Physiol (Lend) 1980;298:1–11
Raemer DB, Francis D, Philip JH, Gabel RA. Variation in PCO2 between arterial blood and peak expired gas during anesthesia. Anesth Analg 1983;62:1065–1069
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Weinger, M.B., Brimm, J.E. End-tidal carbon dioxide as a measure of arterial carbon dioxide during intermittent mandatory ventilation. J Clin Monitor Comput 3, 73–79 (1987). https://doi.org/10.1007/BF00858353
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00858353