Abstract
The semi-crystalline polymer TPX has been injection moulded into standard tensile bars using a range of barrel temperatures, mould temperatures and injection pressures. Acid etching, microhardness testing and selected volume X-ray pole figures were used to characterize the changes in microstructure and crystalline texture which occurred throughout the range of mouldings. A strong correlation was shown to exist between microstructure and crystalline texture and processing conditions. Three-point bend tests on the injection moulded bars indicated that a ductile-to-brittle transition in failure mode could be induced by changing the moulding conditions, and that this change could be correlated with microstructural and dimensional changes.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
F. C. Frank, A. Keller and A. O'Connor, Phil. Mag. 4 (1959) 200.
E. S. Clark, Plastic Engineers J. 23 (1969) 46.
M. R. Kantz, H. D. Newman Jun and F. H. Stigale, J. Appl. Polymer Sci. 16 (1972) 1249.
B. Heise, H. G. Kiliar, G. Lüpke, P. Schulz, W. Woebeker and J. Zöhren, Kolloid Z. u. Z. Polymere 250 (1972) 120.
D. R. Fitchmun and Z. Mencik, J. Polymer Sci. 11 (1973) 951.
Z. Mencik and D. R. Fitchmun, ibid 11 (1973) 973.
T. W. Owen and D. Hull, Plastics and Polymers 42 (1974) 19.
See G. Dieter Jun, “Mechanical Metallurgy” (McGraw-Hill, 1961).
A. J. Perry and D. J. Rowcliffe, J. Mater. Sci. 8 (1973) 904.
M. A. Rothwell, J. Appl. Crystallog. 4 (1971) 494.
J. E. Preedy and E. J. Wheeler, Nature Physical Science 236 (1972) 60.
D. Lewis, E. J. Wheeler, W. F. Maddons and J. E. Preedy, J. Appl. Crystallog. 4 (1971) 55.
B. D. Cullity, “Elements of X-ray Diffraction” (Addison Wesley, 1956).
L. E. Alexander, “X-ray Diffraction Methods in Polymer Science” (John Wiley, 1969).
A. W. Christiansen, J. Lilley and J. B. Shortall, Fibre Sci. and Tech. 7 (1974) 1.
M. R. Mackley and A. Keller, Polymer 14 (1973) 16.
J. Dlugosz, D. T. Grubb, A. Keller and M. B. Rhodes, J. Mater. Sci. 7 (1972) 142.
F. A. Seyer and B. Hlarácek, Kolloid Z. u. Z. Polymere 251 (1973) 108.
E. S. Clark and C. A. Garber, Int. J. Polym. Mat. 1 (1971) 31.
J. L. S. Wales, I. R. J. Van Leeuwer and R. Van Der Vijgh, Polymer Eng. and Sci. 12 (1972) 358.
L. Camwell and D. Hull, unpublished work.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Bowman, J., Harris, N. & Bevis, M. An investigation of the relationships between processing conditions, microstructure and mechanical properties of an injection moulded semi-crystalline thermoplastic. J Mater Sci 10, 63–76 (1975). https://doi.org/10.1007/BF00541032
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00541032