Summary
A prospective study was performed in 148 elderly patients (over 60 years old) whose intertrochanteric fractures were caused by moderate trauma. The patients were treated with dynamic hip screws and followed up for at least 2 years (average 34 months). The lag screw was placed as the biomechanical analysis favored. Follow-up showed that the majority achieved good union and were without mechanical failure. The authors conclude that a lag screw should ideally be placed inferiorly toward the medial margin in the frontal plane and centrally in the sagittal plane. The length of the lag screw should be such as to extend from 1.0 cm beneath the subchondral bone to the lateral femoral cortex. At least four cortical screws (piercing the cortex at eight points) should be inserted on the distal femoral fragment.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Apel DM, Patwardhan A, Pinzur MS, Dobozi WR (1989) Axial loading studies of unstable intertrochanteric fractures of the femur. Clin Orthop 246:156–164
Bannister GC, Gibson AGF, Ackroyd CE, Newman JH (1990) The fixation and prognosis of trochanteric fractures — a randomized prospective controlled trial. Clin Orthop 254:242–246
Bartucci EJ, Gonzalez MH, Cooperman DR, Freedberg HI, Barmada R, Laros GS (1985) The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis. J Bone Joint Surg [Am] 67:1094–1107
Bombelli R (1983) Osteoarthritis of the hip. Springer, Berlin Heidelberg New York
Candle RJ, Hopson CN, Clarke RP (1987) Unstable intertrochanteric fractures of the hip. Orthop Rev 16:30–41
Davis TRC, Sher JL, Horsman A, Simpson M, Porter BB, Checkatts RG (1990) Intertrochanteric femoral fractures — mechanical failure after internal fixation. J Bone Joint Surg [Br] 72:26–31
DeLee JC, Heckman JD, Lewis AG (1981) Partial fibulectomy for ununited fractures of the tibia. J Bone Joint Surg [Am] 63:1390–1395
Doherty JH, Lyden JP (1979) Intertrochanteric fractures of the hip treated with the hip compression screw — analysis of problems. Clin Orthop 141:184–187
Flores LA, Harrington IJ, Heller M (1990) The stability of intertrochanteric fractures treated with a sliding screw-plate. J Bone Joint Sug [Br] 72:27–40
Jensen JS, Tondevold E, Mossing N (1978) Unstable trochanteric fractures treated with the sliding screw-plate system — a biomechanical study of unstable trochanteric fractures III. Acta Orthop Scand 49:392–397
Juhn A, Krimerman J, Mendes DG (1988) Intertrochanteric fractures of the hip — comparison of nail-plate fixation and Ender's nailing. Arch Orthop Trauma Surg 107:136–139
Koch JC (1917) The laws of bone architecture. Am J Anat 21:177–298
Kyle RF, Gustilo RB, Phemer RF (1979) Analysis of six hundred and twenty-two intertrochanteric hip fractures — a retrospective and prospective study. J Bone Joint Surg [Am] 61:216–221
Kyle RF, Wright TM, Burstein AH (1980) Biomchanical analysis of the sliding characterics of compression hip screw. J Bone Joint Surg [Am] 62:1308–1314
Laros GS, Moore JF (1974) Complications of fixation in intertrochanteric fractures. Clin Orthop 101:110–119
Laskin RS, Gruber MA, Zimmerman AJ (1979) Intertrochanteric fractures of the hip in the elderly — a retrospective analysis of 236 cases. Clin Orthop 141:188–195
Maistrelli G, Gerundini M, Bombelli R (1986) The inclination of the weight bearing surface in the hip joint — the clinical significance of abnormal force. Orthop Rev 15:271–279
Mariani EM, Rand JA (1987) Nonunion of intertrochanteric fractures of the femur following open reduction and internal fixation — results of second attempts to gain union. Clin Orthop 218:81–89
Rao JP, Banzon MT, Weiss AB, Rayhack J (1983) Treatment of unstable intertrochanteric fractures with anatomic reduction and compression hip screw fixation. Clin Orthop 175:65–71
Sarmiento A (1973) Unstable intertrochanteric fractures of the femur. Clin Orthop 92:77–85
Scherfel T (1985) A new type of intramedullary nail for the internal fixation of subtrochanteric fractures of the femur. Int Orthop 8:255–261
Seinscheimer F (1978) Subtrochanteric fractures of the femur. J Bone Joint Surg [Am] 60:300–306
Seinsheimer F (1981) Concerning the proper length of femoral side plate. J Trauma 21:42–45
Waddell JP (1980) Sliding screw fixation for proximal femoral fractures. Orthop Clin North Am 11:607–622
Zimmerman KW, Klasen HJ (1983) Mechanical failure of intramedullary nails after fracture union. J Bone Joint Surg [Br] 65:274–275
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wu, CC., Shih, CH. Biomechanical analysis of the dynamic hip screw in the treatment of intertrochanteric fractures. Arch Orthop Trauma Surg 110, 307–310 (1991). https://doi.org/10.1007/BF00443464
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00443464