Abstract
By means of probability analysis we have compared the diagnostic value of clinical symptoms, m-mode echocardiographic measurements and peripheral arterial flow, assessed by continuous-wave Doppler, in preterm infants with symptomatic patent ductus arteriosus (PDA). Data were obtained in 29 infants with PDA and in 29 controls. The most sensitive clinical finding was a hyperactive precordium. Bounding pulses and a heart murmur were absent in 15% and 20%, respectively of the patients with PDA. M-mode echocardiographic measurements were rather specific for the detection of a PDA but less sensitive. Diastolic backflow in the brachial and femoral arteries was present in the majority of patients with PDA and absent in about 67% of the controls. The values in probability analysis, however, were too low to base a therapy on these findings. The highest sensitivity and specificity (100% each) was found for a disturbed cerebral blood flow with absent or retrograde diastolic perfusion estimated by Doppler sonography.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Abbreviations
- PDA:
-
patent ductus arteriosus
- cw-Doppler:
-
continuous-wave Doppler
- SF:
-
shortening fraction
- LPEP/LVET, RPEP/RVET:
-
left and right ventricular systolic time intervals
- R/F:
-
retrograde/forward flow
References
Archer LNJ, Glass EJ, Godman MJ (1984) The silent ductus arteriosus in idiopathic respiratory distress syndrome. Acta Paediatr Scand 73:652–656
Bada HS, Hajjar W, Chua C, Summer DS (1979) Noninvasive diagnosis of neonatal asphyxia and intraventricular haemorrhage by Doppler ultrasound. J Pediatr 95:775–779
Baylen BG, Ogata H, Ikegami M, Jacobs HC, Jobe AH, Emmanouilides GC (1983) Left ventricular performance and regional blood flows before and after ductus arteriosus occulusion in premature lambs treated with surfactant. Circulation 67:837–843
Goldberg SJ, Allen HD, Sahn DJ (1977) Echocardiographic detection and management of patent ductus arteriosus in neonates with respiratory distress syndrome: a two-and one-half year prospective study. J Clin Ultrasound 5:161–169
Hill A, Volpe J (1982) Decrease in pulsatile flow in the anterior cerebral arteries in infantile hydrocephalus. Pediatrics 69:4–6
Huhta JC, Cohen M, Gutgesell HP (1984) Patency of the ductus arteriosus in normal neonates: two-dimensional echocardiography versus Doppler assessment. J Am Coll Cardiol 4:561–564
Johnson GL, Breart GL, Geiwitz MH, Brenner JI, Lang P, Dooley KJ, Ellison RC (1983) Echocardiographic characteristics of preterm infants with patent ductus arteriosus, Pediatrics 72:864–871
Lees MH, Newcomb BA, Sunderland CO, Droukas P, Reynolds JW (1981) Doppler ultrasonography in evaluation of PDA shunting (letter). J Pediatr 98:852–853
Lundell BPW, Wallgreen CG (1983) Left ventricular systolic time intervals in preterm infants with patent ductus arteriosus. Acta Paediatr Scand 71:105–110
McGrath RL, McGuinnes GA, Way GL Wolfe RR, Nora JJ, Simmons MA (1978) The silent ductus arteriosus. J Pediatr 93:110–113
Perlman JM, Volpe JJ (1982) Cerebral blood flow velocity in relation to intraventricular hemorrhage in the premature newborn infant. J Pediatr 100:956–959
Perlmann JM, Hill A, Volpe JJ (1981) The effect of patent ductus arteriosus on flow velocity in the anterior cerebral arteries: Ductal steal in the premature newborn infant. Pediatr 99:767–771
Pourcelot L (1976) Diagnostic ultrasound for cerebral vascular disease. In: Donald I, Levi S (eds) Present and future of diagnostic ultrasound. Kooyker Scientific Publications, Rotterdam, p 141
Redel DA, Fehske W, Kowalewski S (1983) Detection and hemodynamic description of ductal shunt in premature infants using two dimensional Doppler echocardiography. Rediatr Cardiol 4 [Suppl II]:49–52
Serwer GA (1983) Detection and quantitation of ductus arteriosus flow using continuous wave Doppler ultrasound. Pediatr Cardiol 4 [Suppl II]:53–59
Serwer GA, Amstrong BE, Anderson PAW (1980) Noninvasive detection of retrograde descending aortic flow in infants using continuous wave Doppler ultrasonography. J Pediatr 97:394–400
Serwer GA, Armstrong BE, Anderson PAW (1982) Continuous wave Doppler ultrasonographic quantitation of patent ductus arteriosus flow. J Pediatr 100:297–299
Snider R (1985) The use of Doppler ultrasonography for the evaluation of cerebral artery flow patterns in infants with congenital heart disease. Ultrasound Med Biol 11:503–514
Spach Ms, Serwer GA, Anderson PAW, Canent RV, Levin AR (1980) Pulsatile aortapulmonary pressure-flow dynamics of patent ductus arteriosus in patients with various hemodynamic states. Circulation 61:110–122
Valdes-Cruz LM, Dudell G (1981) Specificity and accuracy of echocardiographic and clinical criteria for diagnosis of patent ductus arteriosus in fluid-restricted infants. J Pediatr 98:298–305
Vick GW, Huhta JC, Gutgesell HP (1985) Assessment of the ductus arteriosus in preterm infants utilizing suprasternal twodimensional/Doppler echocardiography. J Am Coll Cardiol 5:973–977
Author information
Authors and Affiliations
Additional information
Dedicated to Professor Dr. E. Kleihauer on the accasion of his 60th birthday
Rights and permissions
About this article
Cite this article
Kupferschmid, C., Lang, D. & Pohlandt, F. Sensitivity, specificity and predictive value of clinical findings, m-mode echocardiography and continuous-wave Doppler sonography in the diagnosis of symptomatic patent ductus arteriosus in preterm infants. Eur J Pediatr 147, 279–282 (1988). https://doi.org/10.1007/BF00442695
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00442695