Abstract
The use of micellar electrokinetic capillary chromatography (MECC) for the separation of eleven substituted phenols listed by the United States Environmental Protection Agency as priority pollutants was demonstrated. The effects of the pH and ionic strength of the buffer, and the length of the separation column on resolution were investigated. The retention characteristics of the eleven phenols in MECC are discussed.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
Abrahamsson, K. and Xie, T. M.: 1983, ‘Direct Determination of Trace Amounts Of Chlorophenols in Fresh Water, Waste Water And Sea Water’, J. Chromatogr. 279, 199.
Buckman, N. G., Hill, J. O., Magee, R. J. and McCormick, M. J.: 1984, ‘Separation Of Substituted Phenols, Including Eleven Priority Pollutants Using High-Performance Liquid Chromatography’, J. Chromatogr. 284, 441.
Bigely, F. P. and Grob, R. L.: 1985, ‘Determination of Phenols in Water and Wastewater by Post-Column Reaction Detection High Performance Liquid Chromatography’, J. Chromatogr. 350, 407.
Burton, D. E., Sepaniak, M. J. and Maskarinec, M. P.: 1986, ‘Analysis of B6 Vitamers by Micellar Electrokinetic Capillary Chromatography with Laser-Excited Fluorescence Detection’, J. Chromatogr. Sci. 24, 347.
Cohen, A. S., Terabe, S., Smith, J. A. and Karger, B. L.: 1987, ‘High-Performance Capillary Electrophoretic Separation of Bases, Nucleosides, and Oligonucleotides: Retention Manipulation via Micellar Solutions and Metal Additives’, Anal. Chem. 59, 1021.
Li, S. F. Y. and Lee, H. K.: 1988, ‘Retention Prediction of Substituted Phenols in Reversed Phase High Performance Liquid Chromatography’, Chromatographia. 25, 515.
Otsuka, K., Terabe, S., and Ando, T.: 1985, ‘Electrokinetic Chromatography with Micellar Solutions Separation of Phenylthiohydantoin-Amino Acids’, J. Chromatogr. 332, 219.
Otsuka, K., Terabe, S., and Ando, T.: 1985, ‘Electrokinetic Chromatography with Micellar Solutions: Retention Behaviour and Separation of Chlorinated Phenols’, J. Chromatogr. 348, 39.
Swaile, D. F., Burton, D. E., Balchunas, A. T. and Sepaniak, M. J.: 1988, ‘Pharmaceutical Analysis using Micellar Electrokinetic Capillary Chromatography’, J. Chromatogr. Sci. 26, 406.
Terabe, S., Otsuka, K. Ichikawa, Tsuchiya, A. and Ando, T.: 1984, ‘Electrokinetic Separations with Micellar Solutions and Open-Tubular Capillaries’, Anal. Chem. 56, 111.
Terabe, S., Otsuka, K. and Ando, T.: 1985, ‘Electrokinetic Chromatography with Micellar Solution and Open-Tubular Capillary’, Anal. Chem. 57, 834.
Terabe, S., Ozaki, H., Otsuka, K., and Ando, T.: 1985, ‘Electrokinetic Chromatography with 2-O-carboxymethyl-β-cyclodextrin as a Moving “Stationary” Phase’, J. Chromatogr. 332, 211.
Terabe, S., Otsuka, K. and Ando, T.: 1989, ‘Band Broadening in Electrokinetic Chromatography with Micellar Solutions and Open-Tubular Capillaries’, Anal. Chem. 61, 251.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ong, C.P., Ng, C.L., Chong, N.C. et al. Analysis of priority substituted phenols by micellar electrokinetic chromatography. Environ Monit Assess 19, 93–103 (1991). https://doi.org/10.1007/BF00401301
Issue Date:
DOI: https://doi.org/10.1007/BF00401301