Abstract
Background:
Percutaneous liver biopsy is a well-established procedure. Aim of this study was to investigate the usefulness of color Doppler ultrasound (US) for guiding percutaneous biopsy of liver tumors in patients at high risk of bleeding.
Methods:
Forty-seven patients with severe, uncorrectable coagulopathy (platelet count <50 × 109/L and/or prothrombin time ratio [normal/patient] <50%) were submitted to percutaneous biopsy of focal liver lesions using a 21 G cutting needle. The procedure was guided by color Doppler US, avoiding the needle cross into any liver or tumor vessel.
Results:
Biopsy material was adequate for pathological reading in 46/47 cases (97.9%). No major post-biopsy complication was observed. In particular, no case of hemoperitoneum was detected on US examinations performed 2 hours after biopsy. Minor complications (including one subcapsular hematoma) occurred in 4 patients (8.5%).
Conclusions:
Color Doppler US can safely guide percutaneous liver biopsy in patients at high-risk of bleeding.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Bret PM, Fond A, Casola G, et al. Abdominal lesions: a prospective study of clinical efficacy of percutaneous fine-needle biopsy. Radiology 1986;159:345–346
Smith EH. Complications of percutaneous abdominal fine-needle biopsy. Radiology 1991;178:253–258
Sharma P, MacDonald GB, Banaji M. The risk of bleeding after percutaneous liver biopsy: relation to platelet count. J Clin Gastroenterol 1982;4:451–453
McGill DB, Rakela J, Zinsmeister AR, Ott BJ. A 21-year experience with major hemorrhage after percutaneous liver biopsy. Gastroenterology 1990;99:1396–1400
Tanaka S, Kitamuta T, Fujita M, Nakanishi K, Okuda S. Color Doppler flow imaging of liver tumors. AJR 1990;154:509–514
Shimamoto K, Sakuma S, Ishigaki T, Ishiguchi T, Itoh S, Fukatsu H. Hepatocellular carcinoma: evaluation with color Doppler US and MR imaging. Radiology 1992;182:149–153
Sangalli G, Livraghi T, Giordano F. Fine needle biopsy of hepatocellular carcinoma: improvement in diagnosis by microhistology. Gastroenterology 1989;96:524–526
Scott Gazelle G, Haaga JR, Rowland DY. Effect of needle gauge, level of anticoagulation, and target organ on bleeding associated with aspiration biopsy. Radiology 1992;183:509–513
Zins M, Vilgrain V, Gayno S, et al. US-guided percutaneous liver biopsy with plugging of the needle track: a prospective study in 72 high-risk patients. Radiology 1992;184:841–843
Gamble P, Colapinto RF, Stronell RD, Colman JC, Blendis L. Transjugular liver biopsy: a review of 461 biopsies. Radiology 1985;157:589–593
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Lencioni, R., Caramella, D. & Bartolozzi, C. Percutaneous biopsy of liver tumors with color Doppler US guidance. Abdom Imaging 20, 206–208 (1995). https://doi.org/10.1007/BF00200394
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00200394