Abstract
I have performed an internal retinal biopsy on fourteen patients. The technique involves the use of vitrectomy instrumentation endodiathermy, endolaser and vitreous scissors to remove a 1–2 mm2 area of the diseased retina. Endolaser photocoagulation and air-fluid exchange with and without the use of silicone oil conclude the surgery. No significant postoperative complication has been noted in patients undergoing this procedure.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Bird AC, Farber DB, Kreiger AE, Bradley R et al. The potential usefulness to research of retina obtained by biopsy. Invest Ophthalmol Vis Sci 1988; 29: 2–11.
Constable IJ, Slatter DH, Horne R. Chorioretinal biopsy in dogs. Invest Ophthalmol Vis Sci 1979; 19: 603–9.
Peyman GA, Fishman GA, Sanders DR et al. Biopsy of human scleral-chorioretinal tissue. Invest Ophthalmol 1975; 14: 707–10.
Peyman GA, Meisels HI, Batko KA et al. Full-thickness eye wall biopsy. I. An experimental approach to the tissue diagnosis and study of choroidal and retinal lesions. Invest Ophthalmol Vis Sci 1975; 14: 484–7.
Peyman GA, Juarez CP, Raichand M. Full-thickness eye wall biopsy: Long-term results in 9 patients. Br J Ophthalmol 1981; 65: 723–6.
Peyman GA, Barrada A. Retinochoroidectomy ab interno. Ophthalmol Surg 1984; 15: 749–51.
Peyman GA, Charles H. Internal eye wall resection in the management of uveal melanoma. Can J Ophthalmol 1988; 23: 219–23.
Peyman GA, Cohen SB. Ab interno resection of uveal melanoma. Int Ophthalmol 1986; 9: 29–36.
Peyman GA, Hindi M. Ab interno retinochoroidectomy in primates. Arch Ophthalmol 103: 572–5.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Peyman, G.A. Internal retinal biopsy: Surgical technique and results. Int Ophthalmol 14, 101–104 (1990). https://doi.org/10.1007/BF00154209